Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors

被引:0
|
作者
Nicolas Nesseler
Jean-Vincent Frénel
Yoann Launey
Jeff Morcet
Yannick Mallédant
Philippe Seguin
机构
[1] Université Rennes 1,Département d’Anesthésie
[2] Hôpital Pontchaillou,Réanimation 1, Inserm U991, Service de Réanimation Chirurgicale, Hôpital Pontchaillou
来源
Intensive Care Medicine | 2012年 / 38卷
关键词
Pulse oximetry; Shock; Vasopressor therapy; Reflectance technology; Finger transmission sensor; Forehead reflectance sensor;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1718 / 1722
页数:4
相关论文
共 50 条
  • [1] Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors
    Nesseler, Nicolas
    Frenel, Jean-Vincent
    Launey, Yoann
    Morcet, Jeff
    Malledant, Yannick
    Seguin, Philippe
    INTENSIVE CARE MEDICINE, 2012, 38 (10) : 1718 - 1722
  • [2] COMPARISON OF FOREHEAD AND DIGITAL OXIMETRY IN CRITICALLY ILL SHOCKED PATIENTS REQUIRING HIGH DOSE VASOPRESSORS
    Frenel, J. -V.
    Nesseler, N.
    Morcet, J.
    Launey, Y.
    Seguin, P.
    Malledant, Y.
    INTENSIVE CARE MEDICINE, 2011, 37 : S229 - S229
  • [3] Comparison of forehead and finger oximetry sensors during the six minute walk test
    Robertson, Lucy
    Lowry, Rachel
    Sylvester, Karl
    Parfrey, Helen
    Moseley, Beverley
    Sheares, Karen
    Oates, Katrina
    CHRONIC RESPIRATORY DISEASE, 2022, 19
  • [4] Forehead reflectance oximetry: A clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery
    Casati A.
    Squicciarini G.
    Baciarello M.
    Putzu M.
    Salvadori A.
    Fanelli G.
    J. Clin. Monit. Comput., 2007, 5 (271-276): : 271 - 276
  • [5] Reflectance pulse oximetry from core body in neonates and infants: Comparison to arterial blood oxygen saturation and to transmission pulse oximetry
    Kugelman A.
    Wasserman Y.
    Mor F.
    Goldinov L.
    Geller Y.
    Bader D.
    Journal of Perinatology, 2004, 24 (6) : 366 - 371
  • [6] COMPARISON BETWEEN HIGH-DOSE SUFENTANIL OXYGEN AND HIGH-DOSE FENTANYL OXYGEN FOR NEUROANESTHESIA
    SHUPAK, RC
    HARP, JR
    BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (04) : 375 - 381
  • [7] High quantum efficiency annular backside silicon photodiodes for reflectance pulse oximetry in wearable wireless body sensors
    Duun, Sune
    Haahr, Rasmus G.
    Hansen, Ole
    Birkelund, Karen
    Thomsen, Erik V.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (07)
  • [8] Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters
    Choi, S. J.
    Ahn, H. J.
    Yang, M. K.
    Kim, C. S.
    Sim, W. S.
    Kim, J. A.
    Kang, J. G.
    Kim, J. K.
    Kang, J. Y.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (02) : 212 - 217
  • [9] Comparison of forehead Max-Fast pulse oximetry sensor with finger sensor at high positive end-expiratory pressure in adult patients with acute respiratory distress syndrome
    Hodgson, C. L.
    Tuxen, D. V.
    Holland, A. E.
    Keating, J. L.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (06) : 953 - 960
  • [10] PULSE OXIMETER PROBES - A COMPARISON BETWEEN FINGER, NOSE, EAR AND FOREHEAD PROBES UNDER CONDITIONS OF POOR PERFUSION
    CLAYTON, DG
    WEBB, RK
    RALSTON, AC
    DUTHIE, D
    RUNCIMAN, WB
    ANAESTHESIA, 1991, 46 (04) : 260 - 265