Comparison of Coopdech®, CoPilot®, Intubrite®, and Macintosh laryngoscopes for tracheal intubation during pediatric cardiopulmonary resuscitation: a randomized, controlled crossover simulation trial

被引:0
|
作者
Łukasz Szarpak
Łukasz Czyżewski
Zenon Truszewski
Andrzej Kurowski
Tomasz Gaszyński
机构
[1] Medical University of Warsaw,Department of Emergency Medicine
[2] Medical University of Warsaw,Department of Nephrologic Nursing
[3] Cardinal Wyszynski National Institute of Cardiology,Department of Anesthesiology
[4] Medical University of Lodz,Department of Emergency Medicine and Disaster Medicine
来源
关键词
Intubation; Pediatrics; Laryngoscopes; Training; Randomization;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the study was to compare the intubation times and success rates of various laryngoscopes during resuscitation in pediatric emergency intubation with uninterrupted chest compression on a standardized pediatric manikin model. This was a randomized crossover study with 107 paramedic participants. We compared times to successful intubation, intubation success rates, and glottic visibility using a Cormack–Lehane grade for Macintosh, Intubrite®, Coopdech®, and Copilot® laryngoscopes. One hundred seven paramedics (mean age 31.2 ± 7.5 years) routinely involved in the management of prehospital care participated in this study. Intubation success rates (overall effectiveness), which was the primary study endpoint, were highest for the Coopdech® and CoPilot® devices (100 %) and were lowest for Intubrite® (89.7 %, p < 0.001) and Macintosh (80.4 %, p < 0.001). The secondary study endpoint, time to first effective ventilation, was achieved fastest when using the Coopdech® laryngoscope (21.6 ± 6.2 s) and was significantly slower with all other devices (Intubrite® 25.4 ± 10.5 s, p = 0.006; CoPilot® 25.6 ± 7.4 s, p = 0.007; Macintosh 29.4 ± 8.2 s, p < 0.001).
引用
收藏
页码:1517 / 1523
页数:6
相关论文
共 50 条
  • [1] Comparison of CoopdechA®, CoPilotA®, IntubriteA®, and Macintosh laryngoscopes for tracheal intubation during pediatric cardiopulmonary resuscitation: a randomized, controlled crossover simulation trial
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Truszewski, Zenon
    Kurowski, Andrzej
    Gaszynski, Tomasz
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (11) : 1517 - 1523
  • [2] Comparison of Macintosh and Intubrite laryngoscopes for orotracheal intubation by nurses during resuscitation: preliminary data of a randomized crossover simulation-based study
    Smereka, Jacek
    Truszewski, Zenon
    Madziala, Marcin
    Szarpak, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (08): : 1724 - 1725
  • [3] A comparison of the McGrath-MAC and Macintosh laryngoscopes for child tracheal intubation during resuscitation by paramedics. A randomized, crossover, manikin study
    Szarpak, Lukasz
    Truszewski, Zenon
    Czyzewski, Lukasz
    Gaszynski, Tomasz
    Rodriguez-Nunez, Antonio
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (08): : 1338 - 1341
  • [4] McGrath-MAC vs Macintosh laryngoscopes for child tracheal intubation during cardiopulmonary resuscitation
    Claret, Pierre-Geraud
    Bobbia, Xavier
    de La Coussaye, Jean Emmanuel
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (12): : 2453 - 2453
  • [5] Comparison of the Miller Laryngoscope and Videolaryngoscope for Tracheal Intubation by Novice Doctors during Neonatal Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Trial
    Komasawa, Nobuyasu
    Ueki, Ryusuke
    Kaminoh, Yoshiroh
    Nishi, Shin-ichi
    AMERICAN JOURNAL OF PERINATOLOGY, 2015, 32 (09) : 809 - 813
  • [6] Comparison of ETView SL, Airtraq, and Macintosh laryngoscopes for face-to-face tracheal intubation: a randomized crossover manikin trial
    Madziala, Agnieszka
    Majer, Jolanta
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1893 - 1894
  • [7] Simulation of Blind Tracheal Intubation during Pediatric Cardiopulmonary Resuscitation
    Kurowski, Andrzej
    Hryniewiecki, Tomasz
    Czyzewski, Lukasz
    Karczewska, Katarzyna
    Evrin, Togay
    Szarpak, Lukasz
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 190 (11) : 1315 - 1315
  • [8] Comparison of Macintosh and Miller laryngoscopes during pediatric resuscitation
    Brodecki, Marcin
    Sosnowski, Andrzej
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (06): : 1098 - 1099
  • [9] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Łukasz Szarpak
    Łukasz Czyżewski
    Andrzej Kurowski
    Zenon Truszewski
    European Journal of Pediatrics, 2015, 174 : 1325 - 1332
  • [10] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Szarpak, Lukasz
    Czyzewski, Lukasz
    Kurowski, Andrzej
    Truszewski, Zenon
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (10) : 1325 - 1332