Optimization of beam shaping assembly based on D-T neutron generator and dose evaluation for BNCT

被引:0
|
作者
Hamza Naeem
Chaobin Chen
Huaqing Zheng
Jing Song
机构
[1] Chinese Academy of Sciences,Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology
[2] Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions,Key Laboratory of Neutronics and Radiation Safety
[3] University of Science and Technology of China,Key Laboratory of Neutronics and Radiation Safety
[4] Institute of Nuclear Energy Safety Technology,undefined
[5] Chinese Academy of Sciences,undefined
[6] Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions,undefined
[7] Institute of Nuclear Energy Safety Technology,undefined
[8] Chinese Academy of Sciences,undefined
来源
关键词
BNCT; BSA; HINEG; SuperMC;
D O I
暂无
中图分类号
学科分类号
摘要
The feasibility of developing an epithermal neutron beam for a boron neutron capture therapy (BNCT) facility based on a high intensity D-T fusion neutron generator (HINEG) and using the Monte Carlo code SuperMC (Super Monte Carlo simulation program for nuclear and radiation process) is proposed in this study. The Monte Carlo code SuperMC is used to determine and optimize the final configuration of the beam shaping assembly (BSA). The optimal BSA design in a cylindrical geometry which consists of a natural uranium sphere (14 cm) as a neutron multiplier, AlF3 and TiF3 as moderators (20 cm each), Cd (1 mm) as a thermal neutron filter, Bi (5 cm) as a gamma shield, and Pb as a reflector and collimator to guide neutrons towards the exit window. The epithermal neutron beam flux of the proposed model is 5.73 × 109 n/cm2s, and other dosimetric parameters for the BNCT reported by IAEA-TECDOC-1223 have been verified. The phantom dose analysis shows that the designed BSA is accurate, efficient and suitable for BNCT applications. Thus, the Monte Carlo code SuperMC is concluded to be capable of simulating the BSA and the dose calculation for BNCT, and high epithermal flux can be achieved using proposed BSA.
引用
收藏
页码:816 / 821
页数:5
相关论文
共 50 条
  • [1] Optimization of beam shaping assembly based on D-T neutron generator and dose evaluation for BNCT
    Naeem, Hamza
    Chen, Chaobin
    Zheng, Huaqing
    Song, Jing
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (08) : 816 - 821
  • [2] Design and optimization of a beam shaping assembly for BNCT based on D-T neutron generator and dose evaluation using a simulated head phantom
    Rasouli, Fatemeh S.
    Masoudi, S. Farhad
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (12) : 2755 - 2762
  • [3] A novel design of beam shaping assembly to use D-T neutron generator for BNCT
    Kasesaz, Yaser
    Karimi, Marjan
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 317 - 325
  • [4] Monte Carlo study of the beam shaping assembly optimization for providing high epithermal neutron flux for BNCT based on D-T neutron generator
    Hang, Shuang
    Tang, Xiaobin
    Shu, Diyun
    Liu, Yuanhao
    Geng, Changran
    Gong, Chunhui
    Yu, Haiyan
    Chen, Da
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) : 1289 - 1298
  • [5] An evaluation on the design of beam shaping assembly based on the D-T reaction for BNCT
    Asnal, M.
    Liamsuwan, T.
    Onjun, T.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2014 (INST2014), 2015, 611
  • [6] Feasibility of sealed D-T neutron generator as neutron source for liver BNCT and its beam shaping assembly
    Liu, Zheng
    Li, Gang
    Liu, Linmao
    APPLIED RADIATION AND ISOTOPES, 2014, 86 : 1 - 6
  • [7] Design and dosimetric evaluation of beam shaping assembly for BNCT of compact D-T neutron generator by Monte Carlo simulation
    Sahoo, G. S.
    Sharma, S. D.
    Tripathy, S. P.
    Bandyopadhyay, T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):
  • [8] Monte Carlo study of the beam shaping assembly optimization for providing high epithermal neutron flux for BNCT based on D–T neutron generator
    Shuang Hang
    Xiaobin Tang
    Diyun Shu
    Yuanhao Liu
    Changran Geng
    Chunhui Gong
    Haiyan Yu
    Da Chen
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 310 : 1289 - 1298
  • [9] Beam shaping assembly of a D-T neutron source for BNCT and its dosimetry simulation in deeply-seated tumor
    Faghihi, F.
    Khalili, S.
    RADIATION PHYSICS AND CHEMISTRY, 2013, 89 : 1 - 13
  • [10] MCNP optimization of fast neutron beam thermalization device based on D-T neutron generator
    Li, Cong
    Jing, Shiwei
    Gao, Yadong
    Zhang, Wenjuan
    FUSION ENGINEERING AND DESIGN, 2020, 151