Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus

被引:0
|
作者
Dalila Costa
Joana Lourenço
Ana Margarida Monteiro
Beatriz Castro
Patricia Oliveira
Maria Carmo Tinoco
Vera Fernandes
Olinda Marques
Raquel Gonçalves
Carla Rolanda
机构
[1] Life and Health Sciences Research Institute (ICVS),
[2] School of Medicine,undefined
[3] University of Minho,undefined
[4] Gastroenterology Department,undefined
[5] Braga Hospital,undefined
[6] Endocrinology Department,undefined
[7] Braga Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Flash glucose monitoring system (FGMS) is an improved subset of continuous glucose monitoring with a recognized effectiveness on glycemic control, though validation in patients with Liver Cirrhosis (LC) is lacking. To evaluate the accuracy of FGMS in patients with Type 2 Diabetes Mellitus (DM) and LC, a prospective, case-control study was performed in 61 ambulatory patients with LC and DM (LC group, n = 31) or DM (Control group, n = 30). During 14 days, patients performed 4 assessments per day of self-monitoring of blood glucose (SMBG, reference value) followed by FGMS scanning. There were 2567 paired SMBG and FGMS values used in the accuracy analysis, with an overall mean absolute relative difference (MARD) of 12.68% in the LC group and 10.55% in the control group (p < 0,001). In patients with LC, the percentage of readings within Consensus Consensus Error Grid analysis Zone A and A + B were 80.36% and 99,26%, respectively. Sensor clinical accuracy was not affected by factors such as body mass index, age, gender, Child-Pugh score or edematoascitic decompensation. This is the first study to approach FGMS clinical accuracy in LC, revealing a potential usability of this system to monitor glycemic control in this population.
引用
收藏
相关论文
共 50 条
  • [1] Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus
    Costa, Dalila
    Lourenco, Joana
    Monteiro, Ana Margarida
    Castro, Beatriz
    Oliveira, Patricia
    Tinoco, Maria Carmo
    Fernandes, Vera
    Marques, Olinda
    Goncalves, Raquel
    Rolanda, Carla
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] FLASH GLUCOSE-SENSING TECHNOLOGY AS A REPLACEMENT FOR BLOOD GLUCOSE MONITORING FOR THE MANAGEMENT OF DIABETES MELLITUS IN LIVER CIRRHOSIS
    Costa, Dalila
    Monteiro, Margarida
    Goncalves, Raquel
    Rolanda, Carla
    GASTROENTEROLOGY, 2019, 156 (06) : S561 - S561
  • [3] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [4] Flash glucose monitoring system: a required tool to improve glycaemic control in patients with liver cirrhosis
    Costa, Dalila
    Lourenco, Joana
    Monteiro, Ana Margarida
    Fernandes, Vera
    Mendes, Sofia Silva
    Goncalves, Raquel
    Rolanda, Carla
    JOURNAL OF HEPATOLOGY, 2020, 73 : S702 - S702
  • [5] Accuracy of Flash Glucose Monitoring in Hemodialysis Patients With and Without Diabetes Mellitus
    Weber, Michele R.
    Diebold, Matthias
    Wiesli, Peter
    Kistler, Andreas D.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2023, 131 (03) : 132 - 141
  • [6] Monitoring of Diabetes Mellitus Using the Flash Glucose Monitoring System: The Owners' Point of View
    Re, Mariachiara
    Del Baldo, Francesca
    Tardo, Antonio Maria
    Fracassi, Federico
    VETERINARY SCIENCES, 2023, 10 (03)
  • [7] The performance of flash glucose monitoring in critically ill patients with diabetes
    Ancona, Paolo
    Eastwood, Glenn M.
    Lucchetta, Luca
    Ekinci, Elif I.
    Bellomo, Rinaldo
    Martensson, Johan
    CRITICAL CARE AND RESUSCITATION, 2017, 19 (02) : 167 - 174
  • [8] ACCURACY OF FLASH GLUCOSE MONITORING SYSTEM IN HOSPITALIZED PATIENTS WITH TYPE 2 DIABETES MELLITUS - PILOT STUDY
    Schapira Wajman, D.
    Nunes Salles, J. E.
    Marques Naldi, M.
    Aguiar Medeiros, M.
    Ching, T. H.
    Bezerra Parente, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A99 - A99
  • [9] Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus
    Del Baldo, Francesca
    Canton, Claudia
    Testa, Silvia
    Swales, Harry
    Drudi, Ignazio
    Golinelli, Stefania
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (06) : 2296 - 2305
  • [10] The Influence of Skin Thickness on Flash Glucose Monitoring System Accuracy in Dogs with Diabetes Mellitus
    Del Baldo, Francesca
    Diana, Alessia
    Canton, Claudia
    Linta, Nikolina
    Chiocchetti, Roberto
    Fracassi, Federico
    ANIMALS, 2021, 11 (02): : 1 - 12