Separation and quantitative determination of 6α-hydroxycortisol and 6β-hydroxycortisol in human urine by high-performance liquid chromatography with ultraviolet absorption detection

被引:0
|
作者
Hiromi Shibasaki
Sawako Okamoto
Risako Inoue
Misato Okita
Akitomo Yokokawa
Takashi Furuta
机构
[1] School of Pharmacy,Department of Medicinal Chemistry and Clinical Pharmacy
[2] Tokyo University of Pharmacy and Life Sciences,undefined
来源
关键词
6α-hydroxycortisol; 6β-Hydroxycortisol; HPLC-UV; Cortisol 6β-hydroxylation clearance;
D O I
暂无
中图分类号
学科分类号
摘要
The present study developed an high-performance liquid chromatography (HPLC) method for the simultaneous determination of urinary metabolites of endogenous cortisol, 6α-hydroxycortisol (6α-OHF) and 6β-hydroxycortisol (6β-OHF), in human urine, using 6α-hydroxycorticosterone as internal standard. 6α-OHF and 6β-OHF were extracted from urine with ethyl acetate by using a Sep-Pak C18 plus cartridge. Separation of the stereoisomers was achieved on a reversed-phase hybrid column by a gradient elution of (A) 0.05 M KH2PO4–0.01 M CH3COOH (pH 3.77) and (B) 0.05 M KH2PO4–0.01 M CH3COOH/acetonitrile (2:3, v/v). 6α-OHF and 6β-OHF were well separated on an XTerra MS C18 5 μm column using two types of stepwise gradient elution program (programs 2 and 3). Resolutions of 6α-OHF and 6β-OHF were Rs = 4.41 for program 2 and Rs = 4.60 for program 3. The analysis was performed within 23~26 min, monitored by UV absorbance at 239 nm. The lower limits of detection of 6α-OHF and 6β-OHF were 0.80 ng per injection (s/n = ca. 8), and the lower limits of quantification were 5.02 ng/ml for 6α-OHF and 41.08 ng/ml for 6β-OHF, respectively. The within-day reproducibilities in the amounts of 6α-OHF and 6β-OHF determined were in good agreement with the actual amounts added, the relative errors being −5.37% and −3.73% (gradient 2) and −5.69% and −3.96% (gradient 3) for both 6α-OHF and 6β-OHF, respectively. The inter-assay precisions (RSDs) for 6α-OHF and 6β-OHF were less than 1.99% (gradient 2) and 2.61% (gradient 3), respectively. The present HPLC method was applied to the measurement of 6α-OHF and 6β-OHF in urine to evaluate the time courses of 6α-hydroxylation and 6β-hydroxylation clearances of cortisol during 40 days for phenotyping CYP3A in a healthy subject.
引用
收藏
页码:2945 / 2952
页数:7
相关论文
共 50 条
  • [1] Separation and quantitative determination of 6α-hydroxycortisol and 6β-hydroxycortisol in human urine by high-performance liquid chromatography with ultraviolet absorption detection
    Shibasaki, Hiromi
    Okamoto, Sawako
    Inoue, Risako
    Okita, Misato
    Yokokawa, Akitomo
    Furuta, Takashi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (09) : 2945 - 2952
  • [2] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF 6-BETA-HYDROXYCORTISOL IN URINE
    ONO, T
    TANIDA, K
    SHIBATA, H
    KONISHI, H
    SHIMAKAWA, H
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1986, 34 (06) : 2522 - 2527
  • [3] STUDIES ON STEROIDS .182. DETERMINATION OF 6-BETA-HYDROXYCORTISOL IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    GOTO, J
    SHAMSA, F
    NAMBARA, T
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (11): : 1977 - 1985
  • [4] DETERMINATION OF URINARY CORTISOL AND 6-BETA-HYDROXYCORTISOL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NAKAMURA, J
    YAKATA, M
    CLINICA CHIMICA ACTA, 1985, 149 (2-3) : 215 - 224
  • [5] DETERMINATION OF 6-BETA-HYDROXYCORTISOL IN URINE BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    HOLBE, R
    HOVERMANN, W
    ROOTS, I
    HILDEBRANDT, AG
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1976, 293 : R61 - R61
  • [6] Simultaneous determination of 6β-hydroxycortisol and cortisol in human urine by high performance liquid chromatography using ultraviolet detector for CYP3A4 phenotyping
    Ghazaly, Essam A.
    Johnston, Atholl
    Joel, Simon P.
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2007, 63 (06) : 790 - 790
  • [7] Simultaneous determination of 6β-hydroxycortisol and cortisol in human urine and plasma by liquid chromatography with ultraviolet absorbance detection for phenotyping the CYP3A activity
    Hu, ZY
    Gong, QA
    Hu, XL
    Wang, LQ
    Cao, YJ
    Cao, W
    Yu, Q
    Cheng, ZN
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 826 (1-2): : 238 - 243
  • [8] THE ESTIMATION OF 6-BETA-HYDROXYCORTISOL IN URINE - A COMPARISON OF 2 METHODS - HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND RADIOIMMUNOASSAY
    GERBERTARAS, E
    PARK, BK
    OHNHAUS, EE
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 525 - 527
  • [9] Simultaneous Determination of 6β-Hydroxycortisol and 6β-Hydroxycortisone in Human Urine by LC with UV Absorbance Detection
    Xi Luo
    Lijun Zhu
    Wei Wu
    Xiaoxi Sheng
    Ningfang Cai
    Shikun Liu
    Zeneng Cheng
    Chromatographia, 2009, 70 : 1215 - 1219
  • [10] Simultaneous Determination of 6β-Hydroxycortisol and 6β-Hydroxycortisone in Human Urine by LC with UV Absorbance Detection
    Luo, Xi
    Zhu, Lijun
    Wu, Wei
    Sheng, Xiaoxi
    Cai, Ningfang
    Liu, Shikun
    Cheng, Zeneng
    CHROMATOGRAPHIA, 2009, 70 (7-8) : 1215 - 1219