Off-resonance insensitive LGE MRI for imaging ventricular scar without image artifacts induced by cardiac devices

被引:0
|
作者
Ravi Ranjan
Eugene G Kholmovski
Eun-Kee Jeong
Kyungpyo Hong
Joshua Blauer
Brent D Wilson
Christopher J McGann
Daniel Kim
机构
[1] University of Utah,Division of Cardiology, Internal Medicine
[2] University of Utah,UCAIR, Radiology
[3] University of Utah,Department of Bioengineering
关键词
Image Artifact; Myocardial Scar; Image Quality Score; Gold Standard Test; Cardiac Device;
D O I
10.1186/1532-429X-16-S1-O54
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 8 条
  • [1] Off-Resonance Insensitive LGE MRI for Imaging Ventricular Scar Without Image Artifacts Induced by Cardiac Devices
    Ranjan, Ravi
    McGann, Christopher J.
    Jeong, Eun K.
    Han, Frederick
    Akoum, Nazem
    Hong, Kyung P.
    Kholmovski, Eugene G.
    Marrouche, Nassir F.
    Kim, Daniel
    CIRCULATION, 2013, 128 (22)
  • [2] Analysis and correction of off-resonance artifacts in echo-planar cardiac diffusion tensor imaging
    van Gorkum, Robbert J. H.
    von Deuster, Constantin
    Guenthner, Christian
    Stoeck, Christian T.
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2561 - 2576
  • [3] MRI SAFE PACEMAKER LEADS ALLOW CARDIAC MAGNETIC RESONANCE IMAGING WITHOUT ANY ARTIFACTS
    Binner, L.
    Merkle, N.
    Kunze, M.
    Bornstedt, A.
    Rasche, V.
    Rottbauer, W.
    Bernhardt, P.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S34 - S34
  • [4] Magnetic resonance imaging (MRI) induced ‘hypoxia artifacts’ on pulse oximetry: how reliable are MRI compatible monitoring devices?
    Ajay Prasad Hrishi
    Karen Ruby Lionel
    Unnikrishnan Prathapadas
    Anju Das Thulasi Das
    Journal of Clinical Monitoring and Computing, 2018, 32 : 1155 - 1156
  • [5] Magnetic resonance imaging (MRI) induced "hypoxia artifacts' on pulse oximetry: how reliable are MRI compatible monitoring devices?
    Hrishi, Ajay Prasad
    Lionel, Karen Ruby
    Prathapadas, Unnikrishnan
    Das, Anju Das Thulasi
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (06) : 1155 - 1156
  • [6] The value of scar mapping by cardiac magnetic resonance imaging pre ablation for ventricular tachycardia: should an implantable cardioverter defibrillator put you off?
    Seraphim, A.
    Bhuva, A.
    Moon, J.
    Manisty, C.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 39 - 39
  • [7] Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator
    Hong, KyungPyo
    Jeong, Eun-Kee
    Wall, T. Scott
    Drakos, Stavros G.
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 336 - 345
  • [8] Wideband late gadolinium enhanced magnetic resonance imaging for imaging myocardial scar without image artefacts induced by implantable cardioverter-defibrillator: a feasibility study at 3 T
    Ranjan, Ravi
    McGann, Christopher J.
    Jeong, Eun-Kee
    Hong, KyungPyo
    Kholmovski, Eugene G.
    Blauer, Josh
    Wilson, Brent D.
    Marrouche, Nassir F.
    Kim, Daniel
    EUROPACE, 2015, 17 (03): : 483 - 488