The reliability of toe systolic pressure and the toe brachial index in patients with diabetes

被引:0
|
作者
Mary T Romanos
Anita Raspovic
Byron M Perrin
机构
[1] La Trobe University,Department of Podiatry and Musculoskeletal Research Centre, Faculty of Health Sciences
[2] La Trobe University,La Trobe Rural Health School and Musculoskeletal Research Centre, Faculty of Health Sciences
关键词
Ankle Brachial Index; Adjusted Alpha Level; Manual Sphygmomanometer; Brachial Systolic Pressure; Ankle Brachial Index;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
    Mary Romanos
    Anita Raspovic
    Byron Perrin
    Journal of Foot and Ankle Research, 4 (Suppl 1)
  • [2] The reliability of toe systolic pressure and the toe brachial index in patients with diabetes
    Romanos, Mary T.
    Raspovic, Anita
    Perrin, Byron M.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2010, 3
  • [3] Inter-rater reliability of automated devices for measurement of toe systolic blood pressure and the toe brachial index
    Sonter, Jennifer
    Sadler, Sean
    Chuter, Vivienne
    BLOOD PRESSURE MONITORING, 2015, 20 (01) : 47 - 51
  • [4] Toe blood pressure and toe-brachial index
    Rich, Kathleen
    JOURNAL OF VASCULAR NURSING, 2015, 33 (04) : 164 - 166
  • [5] Toe-brachial index and toe systolic blood pressure for the diagnosis of peripheral arterial disease
    Tehan, Peta E.
    Mills, Joseph
    Leask, Sarah
    Oldmeadow, Christopher
    Peterson, Benjamin
    Sebastian, Mathew
    Chuter, Viv
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2024, (10):
  • [6] Interrater and intrarater reliability of photoplethysmography for measuring toe blood pressure and toe-brachial index in people with diabetes mellitus
    Christopher Scanlon
    Kris Park
    David Mapletoft
    Lindy Begg
    Joshua Burns
    Journal of Foot and Ankle Research, 5
  • [7] Interrater and intrarater reliability of photoplethysmography for measuring toe blood pressure and toe-brachial index in people with diabetes mellitus
    Scanlon, Christopher
    Park, Kris
    Mapletoft, David
    Begg, Lindy
    Burns, Joshua
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2012, 5
  • [8] Diagnostic thresholds for absolute systolic toe pressure and toe-brachial index in diabetic foot screening
    Ng, Chuan Guan
    Cheong, Cherry Ya Wen
    Chan, Wan Chin
    Ho, Sean Wei Loong
    Phua, Melissa Susan Li Ann
    Anuar, Khalid
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2022, 51 (03) : 143 - 148
  • [9] The effect of pretest rest time on automated measures of toe systolic blood pressure and the toe brachial index
    Sadler, Sean G.
    Hawke, Fiona E.
    Chuter, Vivienne H.
    BLOOD PRESSURE MONITORING, 2015, 20 (05) : 245 - 248
  • [10] Consistency of Toe Systolic Pressures, Brachial Systolic Pressures, and Toe-Brachial Indices in People with and without Diabetes
    Trevethan, Robert
    CURRENT DIABETES REVIEWS, 2019, 15 (02) : 85 - 92