Accuracy of a hand-held resistance-free flowmeters for flow adjustments of Hirst-Type pollen traps

被引:0
|
作者
Mariel Suarez-Suarez
Jose M. Maya-Manzano
Bernard Clot
Marie-José Graber
Christine Sallin
Fiona Tummon
Jeroen Buters
机构
[1] Technical University and Helmholtz Center,Member of the German Center for Lung Research (DZL), Zentrum für Allergie & Umwelt Center of Allergy & Environment (ZAUM)
[2] Federal Office of Meteorology and Climatology MeteoSwiss,Department of Chemical and Environmental Engineering, Regional Campus of International Excellence “Campus Mare Nostrum”
[3] Technical University of Cartagena,undefined
来源
Aerobiologia | 2023年 / 39卷
关键词
Hirst-type; Pollen; Spore; Trap; Flow; Flow rate resistance;
D O I
暂无
中图分类号
学科分类号
摘要
The Hirst-type pollen trap (1952) is the most common device for aerobiological measurements of pollen and fungal spores in ambient air. In the 1960s the in-line flowmeter was removed and studies since then showed considerable variability in the airflow pumped through the instrument when using hand-held rotameters with an internal airflow resistance to adjust flowrates. To avoid this problem, our study compared the variability of airflow rates of Hirst-type traps when using commercially-available low-resistance airflow meters (heat anemometers) at various timescales. Experiments were conducted in Munich (Germany) and Payerne (Switzerland), using 4 different easyFlux® instruments and 6 Hirst-type pollen traps. Measurements were taken on an hourly basis from dawn to dusk at both locations, and in addition at Payerne, weekly observations over a period of one year. When using the common hand-held rotameters (with airflow resistance) the flow was 28.3% lower than with resistance-free flowmeter (i.e., measured 10 L/min which was in reality 12.8 L/min). The coefficient of variation between the four easyFlux® devices ranged from 0.32% to 1.55% over one day and from 2.88% to 8.17% over an entire year. Some of the traps showed surprising flow variations during the day. Furthermore, flowrates deviated more when measurements were made at the point where the double-sided tape is behind the orifice than elsewhere on the drum. The measurements away from this point are representative of the flow rates for most of the period of operation and flow calibration should thus be carried out away from this point, contrary to the current procedure.
引用
收藏
页码:143 / 148
页数:5
相关论文
共 7 条
  • [1] Accuracy of a hand-held resistance-free flowmeters for flow adjustments of Hirst-Type pollen traps
    Suarez-Suarez, Mariel
    Maya-Manzano, Jose M. M.
    Clot, Bernard
    Graber, Marie-Jose
    Sallin, Christine
    Tummon, Fiona
    Buters, Jeroen
    AEROBIOLOGIA, 2023, 39 (01) : 143 - 148
  • [2] Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment
    Trivino, M. M.
    Maya-Manzano, J. M.
    Tummon, F.
    Clot, B.
    Grewling, L.
    Schmidt-Weber, C.
    Buters, J.
    AEROBIOLOGIA, 2023, 39 (02) : 257 - 273
  • [3] Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment
    M. M. Triviño
    J. M. Maya-Manzano
    F. Tummon
    B. Clot
    Ł. Grewling
    C. Schmidt-Weber
    J. Buters
    Aerobiologia, 2023, 39 : 257 - 273
  • [4] Correction to: Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment
    M. M. Triviño
    J. M. Maya-Manzano
    F. Tummon
    B. Clot
    Ł. Grewling
    C. Schmidt-Weber
    J. Buters
    Aerobiologia, 2023, 39 : 389 - 390
  • [5] Variability between Hirst-type pollen traps is reduced by resistance-free flow adjustment (vol 39, pg 257, 2023)
    Trivino, M. M.
    Maya-Manzano, J. M.
    Tummon, F.
    Clot, B.
    Grewling, L.
    Schmidt-Weber, C.
    Buters, J.
    AEROBIOLOGIA, 2023, 39 (03) : 389 - 390
  • [6] Errors in determining the flow rate of Hirst-type pollen traps
    Jose Oteros
    Jeroen Buters
    Gottfried Laven
    Stefani Röseler
    Reinhard Wachter
    Carsten Schmidt-Weber
    Frieder Hofmann
    Aerobiologia, 2017, 33 : 201 - 210
  • [7] Errors in determining the flow rate of Hirst-type pollen traps
    Oteros, Jose
    Buters, Jeroen
    Laven, Gottfried
    Roeseler, Stefani
    Wachter, Reinhard
    Schmidt-Weber, Carsten
    Hofmann, Frieder
    AEROBIOLOGIA, 2017, 33 (02) : 201 - 210