Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Sixty-two individuals (mean age = 67.5 years) diagnosed with unilateral hip OA participated in this study. The JPS tests were evaluated using a digital inclinometer in hip flexion and abduction directions. The absolute difference between target and reproduced angle (repositioning error) in degrees was taken to measure JPS accuracy. The intraclass correlation coefficient (ICC (2.k), was used to assess the reliability. The Intra rater-reliability for hip JPS tests showed very good agreement in the lying position (hip flexion-ICC = 0.88–0.92; standard error of measurement (SEM) = 0.06–0.07, hip abduction-ICC = 0.89–0.91; SEM = 0.06–0.07) and good agreement in the standing position (hip flexion-ICC = 0.69–0.72; SEM = 0.07, hip abduction-ICC = 0.66–0.69; SEM = 0.06–0.08). Likewise, inter-rater reliability for hip JPS tests demonstrated very good agreement in the lying position (hip flexion-ICC = 0.87–0.89; SEM = 0.06–0.07, hip abduction-ICC = 0.87–0.91; SEM = 0.07) and good agreement in the standing position (hip flexion-ICC = 0.64–0.66; SEM = 0.08, hip abduction-ICC = 0.60–0.72; SEM = 0.06–0.09). The results support the use of hip JPS tests in clinical practice and should be incorporated in assessing and managing elderly participants with hip OA.
引用
收藏
相关论文
共 12 条
  • [1] Reliability of hip joint position sense tests using a clinically applicable measurement tool in elderly participants with unilateral hip osteoarthritis
    Reddy, Ravi Shankar
    Tedla, Jaya Shanker
    Alshahrani, Mastour Saeed
    Asiri, Faisal
    Kakaraparthi, Venkata Nagaraj
    Samuel, Paul Silvian
    Kandakurti, Praveen Kumar
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Reliability of four methods for the measurement of joint space width in osteoarthritis of the hip.
    Hilliquin, P
    Cadet, C
    Conrozier, T
    Vignon, E
    Coste, J
    ARTHRITIS AND RHEUMATISM, 2002, 46 (09): : S150 - S151
  • [3] Late Isometric Assessment of Hip Abductor Muscle and Its Relationship with Functional Tests in Elderly Women Undergoing Replacement of Unilateral Hip Joint
    Melchiorri, Giovanni
    Viero, Valerio
    Triossi, Tamara
    Sorge, Roberto
    Marchetti, Chiara
    Arena, Nicola Eugenio
    Tancredi, Virginia
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2015, 94 (10) : 758 - 767
  • [4] Reliability and measurement error of the Osteoarthritis Research Society International (OARSI) recommended performance-based tests of physical function in people with hip and knee osteoarthritis
    Dobson, F.
    Hinman, R. S.
    Hall, M.
    Marshall, C. J.
    Sayer, T.
    Anderson, C.
    Newcomb, N.
    Stratford, P. W.
    Bennell, K. L.
    OSTEOARTHRITIS AND CARTILAGE, 2017, 25 (11) : 1792 - 1796
  • [5] Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis
    Baert, Isabel A. C.
    Lluch, Enrique
    Struyf, Thomas
    Peeters, Greta
    Van Oosterwijck, Sophie
    Tuynman, Joanna
    Rufai, Salim
    Struyf, Filip
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2018, 35 : 105 - 109
  • [6] Influence of the experience of the reader on reliability of joint space width measurement. A cross-sectional multiple reading study in hip osteoarthritis
    Ornetti, Paul
    Maillefert, Jean-Francis
    Paternotte, Simon
    Dougados, Maxime
    Gossec, Laure
    JOINT BONE SPINE, 2011, 78 (05) : 499 - 505
  • [7] Concurrent Criterion-related Validity, Reliability, and Responsiveness to Treatment of the Figure-of-Four Position for Measurement of Anterior Hip Joint Structures Tightness
    Coloma Martinez, Tomas
    Lluch, Enrique
    Torres-Cueco, Rafael
    Pecos-Martin, Daniel
    McConnell, Jenny
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2018, 41 (09) : 780 - 788
  • [8] THE INTER-RATER AND INTRA-RATER RELIABILITY OF GLENOHUMERAL JOINT POSITION AND MOVEMENT SENSE TESTS APPLIED USING AN ISOKINETIC DYNAMOMETER
    Arslan, Serdar
    Yapali, Gokmen
    TURKISH JOURNAL OF PHYSIOTHERAPY REHABILITATION-TURK FIZYOTERAPI VE REHABILITASYON DERGISI, 2022, 33 (03): : 210 - 218
  • [9] Reliability and measurement precision of concentric-to-isometric and eccentric-to-isometric knee active joint position sense tests in uninjured physically active adults
    Clark, Nicholas C.
    Akins, Jonathan S.
    Heebner, Nicholas R.
    Sell, Timothy C.
    Abt, John P.
    Lovalekar, Mita
    Lephart, Scott M.
    PHYSICAL THERAPY IN SPORT, 2016, 18 : 38 - 45
  • [10] Comparisons and Associations between Hip-Joint Position Sense and Glycosylated Hemoglobin in Elderly Subjects with Type 2 Diabetes Mellitus-A Cross-Sectional Study
    Asiri, Faisal
    Reddy, Ravi Shankar
    Narapureddy, Bayapa Reddy
    Raizah, Abdullah
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (23)