Single analysis of human hair for determining halogens and sulfur after sample preparation based on combustion reaction

被引:0
|
作者
Marcia Foster Mesko
Rodrigo Mendes Pereira
Priscila Tessmer Scaglioni
Diogo La Rosa Novo
机构
[1] Universidade Federal de Pelotas,Centro de Ciências Químicas, Farmacêuticas e de Alimentos
来源
关键词
Ion chromatography; Mass spectrometry; Inductively coupled plasma optical emission spectrometry; Inductively coupled plasma mass spectrometry; Microwave-induced combustion; Biological matrices analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A single analysis of hair for determining halogens (chlorine, bromine, fluorine, and iodine) and sulfur by ion chromatography with suppressed conductivity and mass spectrometry detection (IC-MS) was proposed. Inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) were also used to compare the results. For this purpose, 300 mg of human hair were digested by microwave-induced combustion (MIC) using 20 bar of oxygen pressure. The analytes were absorbed in 100 mmol L−1 NH4OH. Trueness of the proposed method was evaluated by analysis of a CRM of human hair; by recovery tests, using standard solution at two levels (50% and 100%), and by comparison of results with those obtained by ICP OES (Cl and S) and ICP-MS (Br and I). Suitable recoveries (ranging from 92 to 105%) were obtained, and the results from CRM analysis did not differ significantly from those described in the certificate. Moreover, results obtained by IC-MS did not present significant differences (p > 0.05) from those obtained by ICP OES and by ICP-MS. Precision was evaluated in terms of repeatability and intermediate precision, and the relative standard deviations were always lower than 8%. The proposed method presented good accuracy and it is a reliable strategy for human hair analysis. Final digests obtained using the MIC method were fully compatible with all proposed determination techniques. Compared to others reported in the literature, the proposed method presents several advantages, especially given that it is possible to determine halogens and sulfur in a single analysis.
引用
收藏
页码:4873 / 4881
页数:8
相关论文
共 26 条
  • [1] Single analysis of human hair for determining halogens and sulfur after sample preparation based on combustion reaction
    Mesko, Marcia Foster
    Pereira, Rodrigo Mendes
    Scaglioni, Priscila Tessmer
    Novo, Diogo La Rosa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (19) : 4873 - 4881
  • [2] Comparison of sample preparation methods for elemental analysis of human hair
    Dombovari, J
    Papp, L
    MICROCHEMICAL JOURNAL, 1998, 59 (02) : 187 - 193
  • [3] Determination of halogens and sulfur in pitch from crude oil by plasma-based techniques after microwave-induced combustion
    Pereira, Leticia S. F.
    Frohlich, Angelica C.
    Duarte, Fabio A.
    Burrow, Robert A.
    Muller, Edson I.
    Flores, Erico M. M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (08) : 1822 - 1827
  • [4] Indirect determination of chlorine and fluorine in eye shadow by ion chromatography after an eco-friendly sample preparation method based on combustion reaction
    Costa, Vanize C.
    Pereira, Rodrigo M.
    Mello, Julia E.
    Brum, Janaina R.
    Picoloto, Rochele S.
    Mesko, Marcia F.
    MICROCHEMICAL JOURNAL, 2019, 150
  • [5] Human Reaction in Thailand based on Social Media Analysis after the East Japan Great Earthquake
    Hashimoto, Takako
    Chauksuvanit, Teeranoot
    Aramvith, Supavadee
    Shirota, Yukari
    INFORMATION MODELLING AND KNOWLEDGE BASES XXVI, 2014, 272 : 108 - 119
  • [6] Time course of estazolam in single-strand hair based on micro-segmental analysis after controlled oral administration
    Xu, Duoqi
    Ji, Jiaojiao
    Xiang, Ping
    Yan, Hui
    Duan, Gengli
    Shen, Min
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [7] Simplifying Mixed-Food Microwave Sample Preparation for ICP-MS Analysis Utilizing Single Reaction Chamber (SRC) Technology for Trace Metals Analysis for Food Samples
    不详
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 6 (23): : 70 - 74
  • [8] A new sample preparation method for crude or fuel oils by mineralization utilizing single reaction chamber microwave for broader multi-element analysis by ICP techniques
    Yang, Weihang
    Casey, John F.
    Gao, Yongjun
    FUEL, 2017, 206 : 64 - 79
  • [9] Liquid chromatographic analysis of local anesthetics in human plasma after sample preparation by on-line dialysis. Optimization by use of experimental design
    Chiap, P
    Boulanger, B
    Fotsing, L
    Hubert, P
    Crommen, J
    CHROMATOGRAPHIA, 2001, 53 (11-12) : 678 - 686
  • [10] Liquid chromatographic analysis of local anesthetics in human plasma after sample preparation by on-line dialysis. Optimization by use of experimental design
    P. Chiap
    B. Boulanger
    L. Fotsing
    Ph. Hubert
    J. Crommen
    Chromatographia, 2001, 53 : 678 - 686