Change in Efficiency of Flow Path of Modernized and Non-Modernized Turbines Having a Capacity of 300 MW During Operation

被引:0
|
作者
Lazarev M.V. [1 ]
Zakharov A.E. [1 ]
Filatov K.V. [1 ]
Gaev V.D. [2 ]
Belik A.N. [2 ]
Gusev Y.V. [2 ]
Novojilov I.B. [3 ]
Sychiov E.I. [3 ]
Demidov B.V. [3 ]
Katiushin A.V. [3 ]
机构
[1] JSC “All-Russian Power Engineering Institute”, Moscow
[2] Special Design Office “Turbine” — LMZ, PJSC “Power Machines”, St. Petersburg
[3] Konakovskaya GRES, Branch of PJSC “Enel Russia”, Konakovo, Tver’ oblast’
关键词
active type HPC; improved design; internal energy conversion efficiency (η) of a cylinder; IPC; Konakovskaya GRES; LMZ; modernization; nozzle vanes; reactive type HPC; rotor blades; steam turbine; turbine stage;
D O I
10.1007/s10749-023-01504-0
中图分类号
学科分类号
摘要
The results of changes in the thermal efficiency of high-pressure cylinders (HPC) of active and reactive types, as well as intermediate-pressure cylinders (IPC) with stages of an improved design of turbines with a capacity of 300 MW produced by LMZ during long-term operation are presented on the example of Konakovskaya regional hydroelectric power plant (GRES). Recommendations are made regarding the possible use of the proposed technical solutions in power plants with similar turbines. © 2023, Springer Science+Business Media, LLC, part of Springer Nature.
引用
收藏
页码:261 / 264
页数:3