Highly-sensitive fluorescence detection and imaging with microfabricated total internal reflection (TIR)-based devices

被引:2
|
作者
Le N.C.H. [1 ]
Dao D.V. [2 ]
Yokokawa R. [3 ,4 ]
Nguyen T.D. [5 ,6 ]
Wells J.C. [7 ]
Sugiyama S. [8 ]
机构
[1] Microfluidics Group, CSIRO Materials Science and Engineering, Clayton South MDC, VIC
[2] Queensland Micro and Nanotechnology Centre, Griffith University, Southport, QLD
[3] Department of Microengineering, Kyoto University, Yoshida-honmachi, Sakyo Kyoto
[4] CREST JST, Chiyoda-ku, Tokyo, 102-0076
[5] TEMPO Laboratory, University Lille North of France, Le Mont Houy
[6] TEMPO Laboratory, University of Valenciennes and Hainaut Cambresis, Le Mont Houy
[7] Department of Civil Engineering, Ritsumeikan University, Kusatsu, Shiga, 525-8577
[8] Ritsumeikan Global Innovation Research Organization, Ritsumeikan University, Kusatsu, Shiga, 525-8577
来源
Le, N. C. H. (nam.le@csiro.au) | 1600年 / Springer Verlag卷 / 07期
基金
日本科学技术振兴机构;
关键词
Cell imaging; Fluorescent imaging; Micro electro mechanical systems (MEMS); Micro-total analysis systems (micro-TAS); Nano-particle image velocimetry (nano-PIV); Single molecule detection; Total internal reflection (TIR)-based chip;
D O I
10.1007/s12213-012-0043-3
中图分类号
学科分类号
摘要
This paper presents the development and application of several total internal reflection (TIR)-based devices for highly-sensitive and high-resolution fluorescence imaging. Using micro electro mechanical systems (MEMS) fabrication technology, miniaturized single-wavelength and dual-wavelength TIR-based devices have been designed and fabricated. A low-cost and simple fabrication process utilizing TMAH wet etching, deep reactive ion etching (DRIE) and polymer casting has enabled us to integrate several optical components into one single poly(dimethylsiloxane) (PDMS) chip, thus alignment and assembly are eliminated. The slide-format and monolithic chip can be used with both upright and inverted fluorescent microscope with interchangeable sample delivery platforms, i. e. glass slides, flow-cells, microchannels etc... In different configurations, the devices were applied in measurement of the average velocity field of fluorescent beads in pressure-driven flow in a microchannel and then in detecting of single DNA molecules. Another ongoing effort is focused on using the device for cell imaging which will be briefly discussed. These applications are the first step toward integration the TIR-based chips into a detection functionality of a μ-TAS. Our proposed devices are smaller, simpler and less expensive comparing to current objective-type and prism-type total internal reflection fluorescent microscopy (TIRFM) systems. At this moment, our devices could provide quick and low-cost evanescent excitations with one or two wavelengths in upright or inverted fluorescent microscopes using normal objective lenses. In the future, they might be integrated as a detection module in a μ-TAS where highly-sensitivity and high-resolution fluorescence imaging capability is necessary. Finally, some discussion on the limitation and future developments for our devices will be also provided. © 2012 Springer-Verlag.
引用
收藏
页码:45 / 59
页数:14
相关论文
共 50 条
  • [1] MONOLITHIC MULTICOLOR TOTAL INTERNAL REFLECTION (TIR)-BASED CHIP FOR HIGHLY-SENSITIVE MULTIFLUORESCENCE DETECTION AND IMAGING
    Le, Nam Cao Hoai
    Daoi, Dzung Viet
    Yokokawa, Ryuji
    Wells, John
    Sugiyama, Susumu
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 1011 - 1014
  • [2] Design, simulation and fabrication of a total internal reflection (TIR)-based chip for highly sensitive fluorescent imaging
    Le, Nam Cao Hoai
    Dao, Dzung Viet
    Yokokawa, Ryuji
    Wells, John
    Sugiyama, Susumu
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (06) : 1139 - 1146
  • [3] All PDMS Multi-color Total Internal Reflection (TIR)-based Devices for Multi-fluorescence Detection and Imaging
    Le, Nam Cao Hoai
    Dao, Dzung Viet
    Yokokawa, Ryuji
    Wells, John C.
    Sugiyama, Susumu
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1636 - 1639
  • [4] Highly-sensitive fluorescence-based detection of catecholamines as stress markers
    Photonics Research Institute, Japan
    AIST Today (Int. Ed.), 2009, 34 (8-9):
  • [5] Scanning total internal reflection fluorescence imaging
    Quirke, A. M.
    Ameer-Beg, S. M.
    Parsons, M.
    Ng, T.
    Irving, M.
    Vojnovic, B.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES VI, 2006, 6089
  • [6] Highly confined surface imaging by solid immersion total internal reflection fluorescence microscopy
    Wang, Lin
    Vasilev, Cvetelin
    Canniffe, Daniel P.
    Wilson, Luke R.
    Hunter, C. Neil
    Cadby, Ashley J.
    OPTICS EXPRESS, 2012, 20 (03): : 3311 - 3324
  • [7] Total internal reflection-based module for fluorescence and absorbance detection
    Verschooten, Tom
    Ottevaere, Heidi
    Vervaeke, Michael
    Van Erps, Juergen
    Thienpont, Hugo
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2014, 13 (03):
  • [8] Note: An easy way to enable total internal reflection-fluorescence correlation spectroscopy (TIR-FCS) by combining commercial devices for FCS and TIR microscopy
    Yordanov, Stoyan
    Best, Andreas
    Weisshart, Klaus
    Koynov, Kaloian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [9] A Monolithic Dual-Color Total-Internal-Reflection-Based Chip for Highly Sensitive and High-Resolution Dual-Fluorescence Imaging
    Le, Nam Cao Hoai
    Dao, Dzung Viet
    Yokokawa, Ryuji
    Wells, John C.
    Sugiyama, Susumu
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2009, 18 (06) : 1371 - 1381
  • [10] Detection efficiency in total internal reflection fluorescence microscopy
    Leutenegger, Marcel
    Lasser, Theo
    OPTICS EXPRESS, 2008, 16 (12) : 8519 - 8531