Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation

被引:0
|
作者
Maurizio Cereda
Federico Villa
Enrico Colombo
Gianluca Greco
Mirco Nacoti
Antonio Pesenti
机构
[1] Department of Anesthesia and Intensive Care,
[2] Ospedale S. Gerardo dei Tintori,undefined
[3] University of Milan-Bicocca,undefined
[4] via Donizetti 106,undefined
[5] Monza (MI),undefined
[6] 20052 Italy,undefined
来源
Intensive Care Medicine | 2001年 / 27卷
关键词
Mechanical ventilation Suction/instrumentation Gas exchange Alveolar recruitment;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: A closed suction system (CS) maintains connection with the mechanical ventilator during tracheal suctioning and is claimed to limit loss in lung volume and oxygenation. We compared changes in lung volume, oxygenation, airway pressure and hemodynamics during endotracheal suctioning performed with CS and with an open suction system (OS). Design: Prospective, randomized study. Setting: Intensive care unit in a university hospital. Patients: We enrolled ten patients, volume-controlled (VC) ventilated with a Siemens Servo 900 ventilator (PaO2/FIO2 192±70, PEEP 10.7±3.9 cmH2O). Interventions: We performed four consecutive tracheal suction maneuvers, two with CS and two with OS, at 20-min intervals. During the suction maneuvers continuous suction was applied for 20 s. Measurements and main results: We measured end-expiratory lung volume changes (ΔVL), tidal volume (VTrt), respiratory rate (RR) and minute volume (VErt) by respiratory inductive plethysmography; arterial oxygen saturation (SpO2), airway pressure and arterial pressure (PA). Loss in lung volume during OS (ΔVL 1.2±0.7 l) was significantly higher than during CS (ΔVL 0.14±0.1 l). During OS we observed a marked drop in SpO2, while during CS the change was only minor. During CS ventilation was not interrupted and we observed an immediate increase in RR (due to the activation of the ventilator's trigger), while VTrt decreased, VErt was maintained. Conclusions: Avoiding suction-related lung volume loss can be helpful in patients with an increased tendency to alveolar collapse; CS allows suctioning while avoiding dramatic drops in lung volumes and seems to be safe during the VC ventilation setting that we used.
引用
收藏
页码:648 / 654
页数:6
相关论文
共 50 条
  • [1] Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation
    Cereda, M
    Villa, F
    Colombo, E
    Greco, G
    Nacoti, M
    Pesenti, A
    INTENSIVE CARE MEDICINE, 2001, 27 (04) : 648 - 654
  • [2] Closed system endotracheal suctioning maintains lung volume during volume controlled mechanical ventilation
    David Pogson
    Peter Shirley
    Elizabeth Connolly
    Sharon Johnston
    Intensive Care Medicine, 2002, 28 : 222 - 222
  • [3] Closed system endotracheal suctioning maintains lung volume during volume controlled mechanical ventilation
    Pogson, D
    Shirley, P
    Connolly, E
    Johnston, S
    INTENSIVE CARE MEDICINE, 2002, 28 (02) : 222 - 222
  • [4] Closed system (CS) endotracheal suctioning preserves lung volumes and oxygenation during volume controlled ventilation (VCV)
    Cereda, M
    Colombo, E
    Villa, F
    Greco, G
    De Marchi, L
    Pesenti, A
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A86 - A86
  • [5] Side effects of endotracheal suction in pressure- and volume-controlled ventilation
    Almgren, B
    Wickerts, CJ
    Heinonen, E
    Högman, M
    CHEST, 2004, 125 (03) : 1077 - 1080
  • [6] Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation
    Liu, Xiao-Wei
    Jin, Yan
    Ma, Tao
    Qu, Bo
    Liu, Zhi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [7] Volume-controlled versus pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation
    Song, Seok Young
    Jung, Jin Yong
    Cho, Min-Su
    Kim, Jong Hae
    Ryu, Tae Ha
    Kim, Bong Il
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (04) : 258 - 263
  • [8] Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
    Giosa, Lorenzo
    Busana, Mattia
    Pasticci, Iacopo
    Bonifazi, Matteo
    Macri, Matteo Maria
    Romitti, Federica
    Vassalli, Francesco
    Chiumello, Davide
    Quintel, Michael
    Marini, J. J.
    Gattinoni, Luciano
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2019, 7 (01)
  • [9] Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
    Lorenzo Giosa
    Mattia Busana
    Iacopo Pasticci
    Matteo Bonifazi
    Matteo Maria Macrì
    Federica Romitti
    Francesco Vassalli
    Davide Chiumello
    Michael Quintel
    J. J. Marini
    Luciano Gattinoni
    Intensive Care Medicine Experimental, 7
  • [10] Optimizing effects on airway pressure and minute volume during closed endotracheal suctioning: a simulated lung model
    Jung, Fang
    Chou, Shang-Shing P.
    Yang, Shih-Hsing
    Lin, Jau-Chen
    Jow, Guey-Mei
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2021, 97 (07): : 439 - 449