Quantitative Assessment of Steady and Pulsatile Flow Fields in a Parallel Plate Flow Chamber

被引:0
|
作者
Eric A. Nauman
Kurtis J. Risic
Tony M. Keaveny
Robert L. Satcher
机构
[1] University of California,Department of Mechanical Engineering, Orthopaedic Biomechanics Laboratory
[2] Berkeley,Department of Orthopaedic Surgery
[3] University of California,undefined
[4] San Francisco,undefined
来源
关键词
Flow visualization; Parallel plate flow chamber; Pulsatile flow;
D O I
暂无
中图分类号
学科分类号
摘要
Steady and pulsatile flows were imaged and quantified in a parallel plate flow chamber that was designed to allow constant variation of the volumetric flow rate and to minimize pressure gradients across the width of the flow field. Results indicated that both the steady and pulsatile flow fields were uniform across the width of the flow chamber as shown by linear regression analysis. Further, the dynamic effects of the fluid pulse were transmitted almost instantaneously across the length of the flow field. These findings verify that parallel plate devices designed in this manner are suitable for delivering uniform steady and pulsatile shear stress to adherent cell populations in vitro. © 1999 Biomedical Engineering Society.
引用
收藏
页码:194 / 199
页数:5
相关论文
共 50 条
  • [1] Quantitative Assessment of Steady and Pulsatile Flow Fields in a Parallel Plate Flow Chamber
    Nauman, Eric A.
    Risic, Kurtis J.
    Keaveny, Tony M.
    Satcher, Robert L.
    Annals of Biomedical Engineering, 27 (02): : 194 - 199
  • [2] Quantitative assessment of steady and pulsatile flow fields in a parallel plate flow chamber
    Nauman, EA
    Risic, KJ
    Keaveny, TM
    Satcher, RL
    ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (02) : 194 - 199
  • [3] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Kairong Q.
    Weiyuan J.
    Xixi L.
    Zhaorong L.
    Applied Mathematics and Mechanics, 1998, 19 (9) : 851 - 859
  • [4] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Qin, KR
    Jiang, WY
    Li, XX
    Liu, ZR
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 1998, 19 (09) : 851 - 859
  • [5] On analysis of the steady flow in an irrectangular parallel-plate flow chamber
    Fudan Univ, Shanghai, China
    Appl Math Mech Engl Ed, 9 (851-859):
  • [6] An innovative parallel plate flow chamber system for studying cell behavior under pulsatile flow
    Fan, YB
    Li, JC
    Zou, YW
    Jiang, WT
    Li, XN
    Bai, L
    Chen, JK
    RECENT ADVANCES IN FLUID MECHANICS, 2004, : 663 - 666
  • [7] ANALYSIS OF PULSATILE FLOW IN THE PARALLEL-PLATE FLOW CHAMBER WITH SPATIAL SHEAR STRESS GRADIENT
    Qin Kai-rong
    Hu Xu-qu
    Liu Zhao-rong
    JOURNAL OF HYDRODYNAMICS, 2007, 19 (01) : 113 - 120
  • [9] Analysis of Pulsatile Flow in the Parallel-Plate Flow Chamber with Spatial Shear Stress Gradient
    Kai-rong Qin
    Xu-qu Hu
    Zhao-rong Liu
    Journal of Hydrodynamics, 2007, 19 : 113 - 120
  • [10] ON ANALYSIS OF THE STEADY FLOW IN AN IRRECTANGULARPARALLEL-PLATE FLOW CHAMBER
    覃开荣
    姜伟元
    李惜惜
    柳兆荣
    Applied Mathematics and Mechanics(English Edition), 1998, (09) : 851 - 859