Evaluation of patient skin breakdown and comfort with a new face mask for non-invasive ventilation: a multi-center study

被引:0
|
作者
Cesare Gregoretti
Marco Confalonieri
Paolo Navalesi
Vincenzo Squadrone
Pamela Frigerio
Fabio Beltrame
Giorgio Carbone
Giorgio Conti
Federica Gamna
Stefano Nava
Edoardo Calderini
Yoanna Skrobik
Massimo Antonelli
机构
[1] Intensive Care Unit,
[2] Azienda Ospedaliera CTO-CRF-ICORMA,undefined
[3] Via Zuretti 29,undefined
[4] 10100 Turin,undefined
[5] Italy,undefined
[6] Pulmonary Unit and ARTA Institute,undefined
[7] Azienda Ospedaliera di Trieste,undefined
[8] S.da di Fiume 447,undefined
[9] 34100 Trieste,undefined
[10] Italy,undefined
[11] Fondazione Salvatore Maugeri,undefined
[12] Via Ferrata,undefined
[13] 27100 Pavia,undefined
[14] Italy,undefined
[15] Intensive Care Unit and Medical Rehabilitation Department,undefined
[16] S. Luigi Hospital,undefined
[17] Orbassano,undefined
[18] 10100 Turin,undefined
[19] Italy,undefined
[20] Niguarda Hospital,undefined
[21] Pza OspedaleMaggiore 2,undefined
[22] 20100 Milan,undefined
[23] Italy,undefined
[24] Emergency Department Gradenigo Hospital,undefined
[25] C.so Regina Margherita 8/10,undefined
[26] 10153 Turin,undefined
[27] Italy,undefined
[28] Anesthesia and Intensive Care Institute,undefined
[29] Università Cattolica del Sacro Cuore,undefined
[30] Largo Gemelli 1,undefined
[31] 00168 Rome,undefined
[32] Italy,undefined
[33] Intensive Care Unit,undefined
[34] ICP,undefined
[35] Clinica De Marchi,undefined
[36] Via della Commenda 9,undefined
[37] 20132 Milan,undefined
[38] Italy,undefined
[39] Critical Care Division,undefined
[40] Maisonneuve Rosemont Hospital,undefined
[41] 5415 boul de l'Assomption,undefined
[42] Quebec HIT 2M4,undefined
[43] Canada,undefined
来源
Intensive Care Medicine | 2002年 / 28卷
关键词
Non-invasive mask ventilation Face mask Patient comfort Skin breakdown Eye irritation;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To evaluate patient comfort, skin breakdown and eye irritation when comparing a prototype face mask (PM) and conventional face masks (CMs) during non-invasive ventilation. Setting and design: Eight centers (intensive or intermediate care units). Multicenter randomized study. Populations: Patients with acute respiratory failure of different etiologies. Interventions: Patients were randomized to CMs or PM when ventilation was expected to last at least 12 consecutive hours a day for two consecutive days. Patient comfort, skin breakdown and eye irritation, assessed by means of standardized scoring systems, were measured after 24 and 48 h and before discontinuing ventilation. Results: Hundred ninety-four patients were randomized. Forty-seven patients were finally enrolled: PM (24) and CMs (23). Ventilator settings were similar in the two groups at the beginning of the treatment and after 24 and 48 h. Skin breakdown was significantly higher in the CMs group over the study period (p<0.001). Patient comfort was higher in the PM group after 24 and 48 h (p=0.008 and p<0.001, respectively). Eye irritation was absent in both groups after 24 h and did not differ significantly after 48 h (p=0.539). Before ventilation was discontinued skin breakdown and patient comfort were significantly higher in the CMs group, when compared to the PM group (p<0.001 and p=0.003, respectively). Eye irritation was slightly higher in the PM versus CMs group (p=0.21). The time on ventilation was not significantly different between the two groups (p=0.830). Conclusion: The PM significantly reduced skin breakdown while improving patient comfort, compared to the CMs.
引用
收藏
页码:278 / 284
页数:6
相关论文
共 50 条
  • [1] Evaluation of patient skin breakdown and comfort with a new face mask for non-invasive ventilation: a multi-center study
    Gregoretti, C
    Confalonieri, M
    Navalesi, P
    Squadrone, V
    Frigerio, P
    Beltrame, F
    Carbone, G
    Conti, G
    Gamna, F
    Nava, S
    Calderini, E
    Skrobik, Y
    Antonelli, M
    INTENSIVE CARE MEDICINE, 2002, 28 (03) : 278 - 284
  • [2] A New Full-Face Mask for Multifunctional Non-Invasive Ventilation
    Vasconcelos, Renata Santos
    Nogueira, Andrea Nobrega Cirino
    Montenegro Junior, Renan Magalhaes
    Peixoto Junior, Arnaldo Aires
    Ferreira, Lucas Alves
    Sousa, Carlos Eugenio Moreira
    Ricca, Diego Eneas Peres
    da Silveira, Jarbas Aryel Nunes
    Ribeiro, Fabio Cisne
    Cavalcanti, Francisco Rodrigo Porto
    Lobo Filho, Jose Glauco
    MEDICINA-LITHUANIA, 2023, 59 (08):
  • [3] Evaluation of a Novel Mask Adapter to Improve Patient Comfort and Provide Oral Care in Patients on Non-Invasive Ventilation
    Reddy, C.
    Martinez, M. L.
    Nietodelriodeastis, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [4] Non-invasive mechanical ventilation for diagnostic bronchoscopy using a new face mask: an observational feasibility study
    Leo M. A. Heunks
    Charlotte J. R. de Bruin
    Johannes G. van der Hoeven
    Henricus F. M. van der Heijden
    Intensive Care Medicine, 2010, 36 : 143 - 147
  • [5] Non-invasive mechanical ventilation for diagnostic bronchoscopy using a new face mask: an observational feasibility study
    Heunks, Leo M. A.
    de Bruin, Charlotte J. R.
    van der Hoeven, Johannes G.
    van der Heijden, Henricus F. M.
    INTENSIVE CARE MEDICINE, 2010, 36 (01) : 143 - 147
  • [6] Performance of a new "helmet" versus a standard face mask during non-invasive mechanical ventilation
    Chiumello, D
    Carlesso, E
    Cadisco, A
    Paganini, S
    Libassi, G
    Storelli, E
    Rocchi, G
    INTENSIVE CARE MEDICINE, 2002, 28 : S49 - S49
  • [7] Acute respiratory Insufficiency Full-Face-Mask optimizes the non-invasive Ventilation
    Gross, Horst
    PNEUMOLOGIE, 2016, 70 (10): : 627 - 627
  • [8] PATIENT EXPERIENCE OF NON-INVASIVE VENTILATION: A QUALITATIVE STUDY
    Goldman, N.
    Richardson, L.
    Blakey, S.
    Staveacre, L.
    Bloch, S. A. A.
    THORAX, 2016, 71 : A125 - A126
  • [9] Neurally adjusted ventilatory assist (NAVA) improves patient–ventilator interaction during non-invasive ventilation delivered by face mask
    Lise Piquilloud
    Didier Tassaux
    Emilie Bialais
    Bernard Lambermont
    Thierry Sottiaux
    Jean Roeseler
    Pierre-François Laterre
    Philippe Jolliet
    Jean-Pierre Revelly
    Intensive Care Medicine, 2012, 38 : 1624 - 1631
  • [10] Non invasive mechanical ventilation delivered by a new ‘helmet’ versus a standard face mask
    D Chiumello
    E Carlesso
    A Cadisco
    S Paganini
    L Gattinoni
    Critical Care, 6 (Suppl 1):