Fluorescence-Based Calibration Model for In-Situ Measurement of Micro-scaled Lubricant Thickness Distribution at Indentation Interface

被引:1
|
作者
Yoshikawa, Motoya [1 ]
Fujii, Saeko [1 ]
Kadoya, Shotaro [1 ]
Sugihara, Tatsuya [2 ]
Michihata, Masaki [1 ]
Takahashi, Satoru [1 ]
机构
[1] Univ Tokyo, Dept Precis Engn, Hongo 7-3-1,Bunkyo Ku, Tokyo 1138656, Japan
[2] Osaka Univ, Dept Mech Engn, Yamadaoka 2-1, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
Laser-induced fluorescence (LIF); Thickness distribution; In-situ measurement; Lubricant; Mechanical machining; LASER-INDUCED FLUORESCENCE; OIL-FILM THICKNESS; THIN-FILMS; TOOL;
D O I
10.1007/s41871-024-00232-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study proposes a model for the measurement of microscale liquid film thickness distribution using fluorescence signals. The interfacial conditions between the tool and the workpiece in mechanical machining are important for understanding these phenomena and mechanisms. In this study, indentation tests with transparent tools were used to observe interfaces; however, it was challenging to obtain the signal from a thin fluorescent liquid film on smooth and steeply inclined surfaces. Therefore, fluorescence-based measurement, such as laser-induced fluorescence, was employed. To measure the absolute thickness of the thin fluorescent film, calibration of the measurement system is necessary. Therefore, a theoretical model was proposed considering the multiple reflections of excitation light and fluorescence at the inclined surface between the indenter and workpiece. By measuring the profile of the surface topography of the indented workpiece and comparing the results with those measured by a surface profiler, the validity of the proposed calibration method and the performance of this measurement system were demonstrated. The measured surface profiles, including scratches of 2-4 mu m, were in good agreement, demonstrating the validity of the proposed method. Development of a model for measurement of liquid film thickness distribution at a steep, smooth indentation interface.Confirmation of the linearity between the fluorescence intensity and thickness, excitation intensity, and coefficient characterized by reflectance.Consistency of the measured film thickness distribution with the workpiece surface profile.
引用
收藏
页数:13
相关论文
共 10 条
  • [1] In-situ measurement of thickness distribution of fluid at the interface of tool and workpiece via fluorescence
    Michihata, Masaki
    Fujii, Saeko
    Yoshikawa, Motoya
    Kadoya, Shotaro
    Sugihara, Tatsuya
    Takahashi, Satoru
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2024, 73 (01) : 405 - 408
  • [2] Calibration of micro-scaled mechanical parameters of granite based on a bonded-particle model with 2D particle flow code
    Chong Shi
    Wenkun Yang
    Junxiong Yang
    Xiao Chen
    Granular Matter, 2019, 21
  • [3] Calibration of micro-scaled mechanical parameters of granite based on a bonded-particle model with 2D particle flow code
    Shi, Chong
    Yang, Wenkun
    Yang, Junxiong
    Chen, Xiao
    GRANULAR MATTER, 2019, 21 (02)
  • [4] Calibration of an in-situ fluorescence based sensor platform for reliable BOD5 measurement in wastewater
    Khamis, K.
    Bradley, C.
    Gunter, H. J.
    Basevi, G.
    Stevens, R.
    Hannah, D. M.
    WATER SCIENCE AND TECHNOLOGY, 2021, 83 (12) : 3075 - 3091
  • [5] In situ measurement of free zinc in an ischemia model and cell culture using a ratiometric fluorescence-based biosensor
    Zeng, HH
    Bozym, RA
    Rosenthal, RE
    Fiskum, G
    Cotto-Cumba, C
    Westerburg, N
    Fierke, CA
    Stoddard, A
    Cramer, ML
    Frederickson, CJ
    Thompson, R
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS III, 2005, 5692 : 51 - 59
  • [6] In-situ measurement of temporal changes in thickness of polymer adsorbed films from lubricant oil by vertical-objective-based ellipsometric microscopy
    Song, Yuxi
    Fukuzawa, Kenji
    Itoh, Shintaro
    Zhang, Hedong
    Azuma, Naoki
    TRIBOLOGY INTERNATIONAL, 2022, 165
  • [7] A Novel Set-Up for In Situ Measurement and Mapping of Lubricant Film Thickness in a Model Rolling Bearing Using Interferometry and Ratiometric Fluorescence Imaging
    Chennaoui, Mourad
    Fowell, Mark
    Liang, He
    Kadiric, Amir
    TRIBOLOGY LETTERS, 2022, 70 (03)
  • [8] A Novel Set-Up for In Situ Measurement and Mapping of Lubricant Film Thickness in a Model Rolling Bearing Using Interferometry and Ratiometric Fluorescence Imaging
    Mourad Chennaoui
    Mark Fowell
    He Liang
    Amir Kadiric
    Tribology Letters, 2022, 70
  • [9] Wavelet based calibration model building of NIR spectroscopy for in-situ measurement of granule moisture content during fluidized bed drying
    Liu, Jingxiang
    Liu, Tao
    Mu, Guoqing
    Chen, Junghui
    CHEMICAL ENGINEERING SCIENCE, 2020, 226
  • [10] Support Vector Regression based Spectral Calibration Model Building for In-situ Process Measurement via Near-infrared Spectroscopy
    Qu, Xiaoyu
    Li, Tao
    Wu, Yang
    2022 41ST CHINESE CONTROL CONFERENCE (CCC), 2022, : 2531 - 2536