Self-aligned multi-layer X-ray absorption grating using large-area fabrication methods for X-ray phase-contrast imaging

被引:0
|
作者
Abdollah Pil-Ali
Sahar Adnani
Karim S. Karim
机构
[1] University of Waterloo,Department of Electrical and Computer Engineering
[2] University of Waterloo,Centre for Bioengineering and Biotechnology
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
X-ray phase-contrast (XPCi) imaging methods are an emerging medical imaging approach that provide significantly better soft tissue contrast and could function as a viable extension to conventional X-ray, CT, and even some MRI. Absorption gratings play a central role in grating-based XPCi systems, especially because they enable the acquisition of three images in a single exposure: transmission, refraction, and dark-field. An impediment to commercial development and adoption of XPCi imaging systems is the lack of large area, high aspect ratio absorption gratings. Grating technology development, primarily due to technological limitations, has lagged system development and today prevents the scaling up of XPCi system into a footprint and price point acceptable to the medical market. In this work, we report on a self-aligned multi-layer grating fabrication process that can enable large-area X-ray absorption gratings with micron-scale feature sizes. We leverage large-area fabrication techniques commonly employed by the thin-film transistor (TFT) display industry. Conventional ITO-on-glass substrates are used with a patterned film of Cr/Au/Cr that serves as a self-aligned lithography mask for backside exposure. Commonly available SU-8 photoresist is patterned using the backside exposure mask followed by an electroplating step to fill the gaps in the SU-8 with X-ray attenuating material. Consequently, the electroplated patterned material acts as a self-aligned photomask for subsequent SU-8 layer patterning and so forth. The repeatability of the reported process makes it suitable for achieving higher aspect ratio structures and is advantageous over previously reported X-ray LIGA approaches. A prototype three-layer grating, with a thickness of around 40μm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$40\,\upmu \text{m}$$\end{document}, having a visibility of 0.28 at 60kVp\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$60\,\text{kV}_p$$\end{document} with a 70mm×70mm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$70\,\text{mm}\times 70\,\text{mm}$$\end{document} active area was fabricated on a 4-inch glass substrate and demonstrated by modifying a commercially available 3D propagation-based XPCi Microscope. The scalable and cost-effective approach to build larger area X-ray gratings reported in this work can help expedite the commercial development and adoption of previously reported Talbot-Lau, speckle-tracking, as well as coded-aperture XPCi systems for large-area clinical and industrial applications.
引用
收藏
相关论文
共 50 条
  • [1] Self-aligned multi-layer X-ray absorption grating using large-area fabrication methods for X-ray phase-contrast imaging
    Pil-Ali, Abdollah
    Adnani, Sahar
    Karim, Karim S.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] A Novel Multi-Layer Grating Structure for X-ray Phase-Contrast Imaging
    Pil-Ali, Abdollah
    Soltani, Mohammad
    Adnani, Sahar
    Cui, Bo
    Karim, Karim S.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [3] Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer
    Yoneyama, A
    Momose, A
    Koyama, I
    Seya, E
    Takeda, T
    Itai, Y
    Hirano, K
    Hyodo, K
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 277 - 281
  • [4] Fabrication of Large Area X-ray Diffraction Grating for X-ray Phase Imaging
    Noda, Daiji
    Tokuoka, Atsushi
    Katori, Megumi
    Minamiyama, Yasuto
    Yamashita, Kenji
    Nishida, Satoshi
    Hattori, Tadashi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 51 - 56
  • [5] Wide-area phase-contrast X-ray imaging using large X-ray interferometers
    Momose, A
    Takeda, T
    Yoneyama, A
    Koyama, I
    Itai, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 917 - 920
  • [6] Large-area phase-contrast X-ray imaging system based on a two-crystal X-ray interferometer
    Yoneyama, A
    Takeda, T
    Tsuchiya, Y
    Wu, J
    Lwin, TT
    Hyodo, K
    PORTABLE SYNCHROTRON LIGHT SOURCES AND ADVANCED APPLICATIONS, 2004, 716 : 22 - 25
  • [7] Phase-contrast X-ray imaging with a large monolithic X-ray interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Wu, J
    Hirano, K
    Itai, Y
    JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (07) : 280 - 282
  • [8] Large area gratings by x-ray LIGA dynamic exposure for x-ray phase-contrast imaging
    Schroeter, Tobias J.
    Koch, Frieder
    Meyer, Pascal
    Baumann, Martin
    Muench, Daniel
    Kunka, Danays
    Engelhardt, Sabine
    Zuber, Marcus
    Baumbach, Tilo
    Mohr, Juergen
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2017, 16 (01):
  • [9] Fabrication of absorption gratings with X-ray lithography for X-ray phase contrast imaging
    Wang, Bo
    Wang, Yu-Ting
    Yi, Fu-Ting
    Zhang, Tian-Chong
    liu, Jing
    Zhou, Yue
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2018, 32 (13):
  • [10] Quantitative methods in phase-contrast x-ray imaging
    Gureyev, TE
    Stevenson, AW
    Paganin, D
    Mayo, SC
    Pogany, A
    Gao, D
    Wilkins, SW
    JOURNAL OF DIGITAL IMAGING, 2000, 13 (02) : 121 - 126