Measuring phase scintillation at different frequencies with conventional GNSS receivers operating at 1 Hz

被引:0
|
作者
Viet Khoi Nguyen
Adria Rovira-Garcia
José Miguel Juan
Jaume Sanz
Guillermo González-Casado
The Vinh La
Tung Hai Ta
机构
[1] Universitat Politècnica de Catalunya (UPC),Research Group of Astronomy and Geomatics (gAGE)
[2] Hanoi University of Science and Technology (HUST),School of Information and Communication Technology (SoICT)
来源
Journal of Geodesy | 2019年 / 93卷
关键词
Phase scintillation index; Ionospheric scintillation; Global Navigation Satellite System (GNSS); Ionospheric scintillation monitoring receiver (ISMR); Geodetic receiver; Cycle-slip detection;
D O I
暂无
中图分类号
学科分类号
摘要
Ionospheric scintillation causes rapid fluctuations of measurements from Global Navigation Satellite Systems (GNSSs), thus threatening space-based communication and geolocation services. The phenomenon is most intense in equatorial regions, around the equinoxes and in maximum solar cycle conditions. Currently, ionospheric scintillation monitoring receivers (ISMRs) measure scintillation with high-pass filter algorithms involving high sampling rates, e.g. 50 Hz, and highly stable clocks, e.g. an ultra-low-noise Oven-Controlled Crystal Oscillator. The present paper evolves phase scintillation indices implemented in conventional geodetic receivers with sampling rates of 1 Hz and rapidly fluctuating clocks. The method is capable to mitigate ISMR artefacts that contaminate the readings of the state-of-the-art phase scintillation index. Our results agree in more than 99.9% within ± 0.05 rad (2 mm) of the ISMRs, with a data set of 8 days which include periods of moderate and strong scintillation. The discrepancies are clearly identified, being associated with data gaps and to cycle-slips in the carrier-phase tracking of ISMR that occur simultaneously with ionospheric scintillation. The technique opens the door to use huge databases available from the International GNSS Service and other centres for scintillation studies. This involves GNSS measurements from hundreds of worldwide-distributed geodetic receivers over more than one Solar Cycle. This overcomes the current limitations of scintillation studies using ISMRs, as only a few tens of ISMRs are available and their data are provided just for short periods of time.
引用
收藏
页码:1985 / 2001
页数:16
相关论文
共 30 条
  • [1] Measuring phase scintillation at different frequencies with conventional GNSS receivers operating at 1 Hz
    Viet Khoi Nguyen
    Rovira-Garcia, Adria
    Juan, Jose Miguel
    Sanz, Jaume
    Gonzalez-Casado, Guillermo
    The Vinh La
    Tung Hai Ta
    JOURNAL OF GEODESY, 2019, 93 (10) : 1985 - 2001
  • [2] Correction to: Measuring phase scintillation at different frequencies with conventional GNSS receivers operating at 1 Hz
    Viet Khoi Nguyen
    Adria Rovira-Garcia
    José Miguel Juan
    Jaume Sanz
    Guillermo González-Casado
    The Vinh La
    Tung Hai Ta
    Journal of Geodesy, 2020, 94
  • [3] Measuring phase scintillation at different frequencies with conventional GNSS receivers operating at 1 Hz (vol 93, 1985, 2019)
    Viet Khoi Nguyen
    Rovira-Garcia, Adria
    Miguel Juan, Jose
    Sanz, Jaume
    Gonzalez-Casado, Guillermo
    The Vinh La
    Tung Hai Ta
    JOURNAL OF GEODESY, 2020, 94 (01)
  • [4] A method for scintillation characterization using geodetic receivers operating at 1 Hz
    Juan, J. M.
    Aragon-Angel, A.
    Sanz, J.
    Gonzalez-Casado, G.
    Rovira-Garcia, A.
    JOURNAL OF GEODESY, 2017, 91 (11) : 1383 - 1397
  • [5] A method for scintillation characterization using geodetic receivers operating at 1 Hz
    J. M. Juan
    A. Aragon-Angel
    J. Sanz
    G. González-Casado
    A. Rovira-Garcia
    Journal of Geodesy, 2017, 91 : 1383 - 1397
  • [6] An ionospheric scintillation index derived from dual-frequency Doppler measurements released by geodetic GNSS receivers operating at 1 Hz
    Xiaomin Luo
    Zichun Xie
    João Francisco Galera Monico
    Baocheng Zhang
    Vinícius Amadeu Stuani Pereira
    Yidong Lou
    Journal of Geodesy, 2023, 97
  • [7] An ionospheric scintillation index derived from dual-frequency Doppler measurements released by geodetic GNSS receivers operating at 1 Hz
    Luo, Xiaomin
    Xie, Zichun
    Monico, Joao Francisco Galera
    Zhang, Baocheng
    Pereira, Vinicius Amadeu Stuani
    Lou, Yidong
    JOURNAL OF GEODESY, 2023, 97 (07)
  • [8] Amplitude scintillation index derived from C/N0 measurements released by common geodetic GNSS receivers operating at 1 Hz
    Xiaomin Luo
    Shengfeng Gu
    Yidong Lou
    Lei Cai
    Zhizhao Liu
    Journal of Geodesy, 2020, 94
  • [9] Amplitude scintillation index derived from C/N0 measurements released by common geodetic GNSS receivers operating at 1 Hz
    Luo, Xiaomin
    Gu, Shengfeng
    Lou, Yidong
    Cai, Lei
    Liu, Zhizhao
    JOURNAL OF GEODESY, 2020, 94 (02)
  • [10] Extracting an ionospheric phase scintillation index based on 1 Hz GNSS observations and its verification in the Arctic region
    Zhao D.
    Li W.
    Li C.
    Tang X.
    Zhang K.
    Cehui Xuebao/Acta Geodaetica et Cartographica Sinica, 2021, 50 (03): : 368 - 383