Distraction osteogenesis with conventional external fixator for tibial bone loss

被引:0
|
作者
Chanchit Sangkaew
机构
[1] Department of Orthopaedic Surgery,Police General Hospital
来源
International Orthopaedics | 2004年 / 28卷
关键词
Distraction Osteogenesis; Bone Transport; Open Tibial Fracture; Bone Result; Varus Angulation;
D O I
暂无
中图分类号
学科分类号
摘要
Between 1991 and 2002, we treated 21 patients with tibial bone loss using a conventional external fixator. Nine patients had an infected open fracture and 12 patients an infected nonunion. After corticotomy, the bone was distracted at the rate of 1 mm (1 mm/step) on alternate days or every 48 h. The mean follow-up period was 18.7 (6–108) months after fixator removal. The mean new bone gained was 7.4 (2–17) cm. The mean healing index was 44.7 (17–86) days/cm. Total wound infection was resolved in 19 limbs (90.5%), and 11/12 (91.6%) nonunions united. Union with acceptable alignment (<7° of angulation) and limb-length difference (<2.5 cm) was achieved in 18 limbs (85.7%). The bone result was excellent in 17 tibiae, good in three, and poor in one. Eighteen limbs had an excellent and three a good functional result. This modified technique of distraction osteogenesis using AO/ASIF conventional external fixator is safe, cost effective, and a versatile tool in the management of tibial bone loss associated with infected nonunion and open fractures.
引用
收藏
页码:171 / 175
页数:4
相关论文
共 50 条
  • [1] Distraction osteogenesis with conventional external fixator for tibial bone loss
    Sangkaew, C
    INTERNATIONAL ORTHOPAEDICS, 2004, 28 (03) : 171 - 175
  • [2] Distraction osteogenesis of the femur using conventional monolateral external fixator
    Sangkaew, Chanchit
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (09) : 889 - 899
  • [3] Distraction osteogenesis of the femur using conventional monolateral external fixator
    Chanchit Sangkaew
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 889 - 899
  • [4] Distraction osteogenesis using a monolateral external fixator for infected non-union of the femur with bone loss
    Arora, Sumit
    Batra, Sumit
    Gupta, Vikas
    Goyal, Aman
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (02): : 185 - 190
  • [5] Distraction osteogenesis for the treatment of post traumatic complications using a conventional external fixator - A novel technique
    Sangkaew, C
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01): : 185 - 193
  • [6] DISTRACTION OSTEOGENESIS IN THE DOG USING THE ILIZAROV EXTERNAL RING FIXATOR
    ELKINS, AD
    MORANDI, M
    ZEMBO, M
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1993, 29 (05) : 419 - 426
  • [7] Distraction osteogenesis of a fresh fracture site using an external fixator
    Sakurakichi, Keisuke
    Tsuchiya, Hiroyuki
    Watanabe, Koji
    Takeuchi, Akihiko
    Matsubara, Hidenori
    Tomita, Katsuro
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (04) : 390 - 393
  • [8] Distraction osteogenesis for tibial nonunion with bone loss using combined Ilizarov and Taylor spatial frames versus a conventional circular frame
    Abuomira, Ibrahim Elsayed Abdellatif
    Sala, Francesco
    Elbatrawy, Yasser
    Lovisetti, Giovanni
    Alati, Salvatore
    Capitani, Dario
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2016, 11 (03): : 153 - 159
  • [9] Bifocal bone transport (Trifocal distraction compression) with Illizarov external fixator for defective bone loss in tibia
    Zaidi, Itaat Hussain
    Sahito, Badaruddin
    Tariq, Syed Mohammad
    Kumar, Dilip
    Ayoub, Arsalan Khalil
    Ali, Maratib
    RAWAL MEDICAL JOURNAL, 2016, 41 (02): : 209 - 211
  • [10] Tibiotalar arthrodesis by distraction osteogenesis with a circular external fixator over an intramedullary nail
    Tuy, Benjamin
    Beebe, Kathleen
    Sirkin, Michael
    Patterson, Francis
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (01): : E7 - E12