Application of Compton-suppressed self-induced XRF to spent nuclear fuel measurement

被引:0
|
作者
Se-Hwan Park
Kwang Ho Jo
Seung Kyu Lee
Hee Seo
Chaehun Lee
Byung-Hee Won
Seong-Kyu Ahn
Jeong-Hoe Ku
机构
[1] Korea Atomic Energy Research Institute,
[2] KHNP Central Research Institute,undefined
来源
关键词
Self-induced X-ray fluorescence; Spent nuclear fuel; Compton suppression system;
D O I
暂无
中图分类号
学科分类号
摘要
Self-induced X-ray fluorescence (XRF) is a technique by which plutonium (Pu) content in spent nuclear fuel can be directly quantified. In the present work, this method successfully measured the plutonium/uranium (Pu/U) peak ratio of a pressurized water reactor (PWR)’s spent nuclear fuel at the Korea atomic energy research institute (KAERI)’s post irradiation examination facility (PIEF). In order to reduce the Compton background in the low-energy X-ray region, the Compton suppression system additionally was implemented. By use of this system, the spectrum’s background level was reduced by a factor of approximately 2. This work shows that Compton-suppressed selfinduced XRF can be effectively applied to Pu accounting in spent nuclear fuel.
引用
收藏
页码:543 / 547
页数:4
相关论文
共 50 条
  • [1] Application of Compton-Suppressed Self-Induced XRF to Spent Nuclear Fuel Measurement
    Park, Se-Hwan
    Jo, Kwang Ho
    Lee, Seung Kyu
    Seo, Hee
    Lee, Chaehun
    Won, Byung-Hee
    Ahn, Seong-Kyu
    Ku, Jeong-Hoe
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (09) : 543 - 547
  • [2] Assessment of a compton-suppressed spectrometer for measurement of radioactive xenon isotopes
    Fan, Yuanqing
    Li, Qi
    Wang, Ying
    Zhao, Yungang
    Zhang, Xinjun
    Jia, Huaimao
    Chang, Yinzhong
    Liu, Shujiang
    Ai, Xianyun
    Wang, Shilian
    APPLIED RADIATION AND ISOTOPES, 2021, 172
  • [3] Application of Compton-suppressed Gamma-Ray Spectroscopy for Improved Quality Control for production of 82Sr.
    Smith, Suzanne V.
    Muench, Lisa
    Harding, Robert
    Chowdhury, Partha
    Lister, Christopher
    McCutchan, Elizabeth A.
    Nobre, Gustavo
    Sonzogni, Alejandro
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2015, 58 : S390 - S390
  • [4] Geant4 model validation of Compton suppressed system for process monitoring of spent fuel
    Sarah E. Bender
    Kenan Ünlü
    Christopher R. Orton
    Jon M. Schwantes
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 647 - 654
  • [5] Compton suppressed LaBr3 detection system for use in nondestructive spent fuel assay
    Bender, S.
    Heidrich, B.
    Uenlue, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 474 - 481
  • [6] Geant4 model validation of Compton suppressed system for process monitoring of spent fuel
    Bender, Sarah E.
    Uenlue, Kenan
    Orton, Christopher R.
    Schwantes, Jon M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 647 - 654
  • [7] On the design and installation of a Compton-suppressed HPGe spectrometer at the Budapest neutron-induced prompt gamma spectroscopy (NIPS) facility
    Szentmiklosi, Laszlo
    Kis, Zoltan
    Belgya, Tamas
    Berlizov, Andrey N.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (03) : 1605 - 1611
  • [8] Development of hiRX for measurement of plutonium in spent nuclear fuel
    Havrilla, George
    McIntosh, Kathryn
    Holland, Michael
    Gilmore, Robert
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [9] SELF-INDUCED RAINOUT FROM A NUCLEAR WEAPON
    MOLENKAMP, CR
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1979, 60 (05) : 550 - 550
  • [10] EXPERIMENTAL MEASUREMENT OF VACUUM ASSISTED DRYING OF SPENT NUCLEAR FUEL
    Rivera, Matthew
    Manteufel, Randall
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 6B, 2016,