Reliability and efficacy of a monitoring system for an implanted pulse generator

被引:0
|
作者
Osako M. [1 ]
Sato T. [1 ]
Fujii H. [1 ]
Sumita T. [1 ]
Fujiwara H. [1 ]
Nakao Y. [1 ]
Miyamoto T. [1 ]
Enoki C. [1 ]
Otani H. [1 ]
Imamura H. [1 ]
机构
[1] Department of Cardiovascular Surgery, Kansai Medical University, Moriguchi 570-8056
关键词
Atrial fibrillation; Holter recording; Monitoring system; Physiological pacemaker;
D O I
10.1007/s100470200044
中图分类号
学科分类号
摘要
The Selection 900/900E is a physiological pacing device with a sophisticated monitoring system for detecting and analyzing atrial arrhythmias. We have investigated the reliability and efficacy of the Selection monitoring system. Twelve patients with episodes of atrial tachyarrhythmias were implanted the with Selection device (7 men, 5 women, aged 73 ± 6 years old). Ten patients had sick sinus syndrome and two patients had a high degree of atrioventricular (AV) block. All patients underwent 24-h external Holter monitoring after the operation (136 ± 41 days) to evaluate the accuracy of the data recorded by the internal monitoring system. There was no significant difference in counter data between the 24-h external Holter and the internal monitoring systems. Four patients recorded an episode of atrial fibrillation by both systems. In two patients, the 24-h external Holter monitoring system misread DDI pacing after mode switching as sinus rhythm or pacing failure. In another patient, the featured function of this pacing device for atrial tachyarrhythmia was recognized as a sensing failure by the 24-h external Holter monitoring system. The Selection 900/900E monitoring system is a reliable and informative way to evaluate the relevance of pacing therapy.
引用
收藏
页码:233 / 238
页数:5
相关论文
共 50 条
  • [1] Unique Dacron® reaction to an implanted pulse generator
    Parsonnet, V
    Shapiro, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (08): : 864 - 866
  • [2] PRECISION-AMPLITUDE PULSE-GENERATOR FOR THE MONITORING AND STABILIZATION OF A SPECTROMETER SYSTEM
    LAZUTIN, EV
    KUZNETSOV, YV
    PISKAREV, IM
    KHRUSHCHEV, VA
    POPOV, VP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (03) : 683 - 685
  • [3] Reliability assessment for pulse wave measurement using artificial pulse generator
    Chang, Chi-Wei
    Wang, Wei-Kung
    Journal of Medical Engineering and Technology, 2015, 39 (03): : 177 - 184
  • [4] Improvement of an artificial lightning pulse current generator reliability
    Nedzelskyi, O. S.
    Petkov, A. A.
    Plichko, A. V.
    Ponuzhdayeva, E. H.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2010, (02) : 50 - 53
  • [5] PULSE GENERATOR FOR MONITORING LINEARITY OF SPECTROMETRIC EQUIPMENT
    OSTAPENK.AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (02): : 476 - &
  • [6] AUTOMATED TEST SYSTEM FOR MONITORING THE EFFICACY AND RELIABILITY OF LEAKAGE DETECTION IN PIPELINES
    Inaudi, Daniele
    Walder, Roberto
    PROCEEDINGS OF THE 10TH INTERNATIONAL PIPELINE CONFERENCE - 2014, VOL 1, 2014,
  • [7] Tactical Generator Monitoring System
    Stark, Madison
    Leger, Aaron St.
    Barry, Nicholas
    2018 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2018,
  • [8] High reliability low jitter 80 kV pulse generator
    Savage, M. E.
    Stoltzfus, B. S.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2009, 12 (08):
  • [9] Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system
    Gold, MR
    Foster, AH
    Shorofsky, SR
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (05): : 540 - 543
  • [10] Deep Brain Recordings Using an Implanted Pulse Generator in Parkinson's Disease
    Neumann, Wolf-Julian
    Staub, Franziska
    Horn, Andreas
    Schanda, Julia
    Mueller, Joerg
    Schneider, Gerd-Helge
    Brown, Peter
    Kuehn, Andrea A.
    NEUROMODULATION, 2016, 19 (01): : 20 - 23