Fast scan techniques, which are used to reduce scanning times, have raised scanning noise levels in magnetic resonance imaging (MRI) systems, resulting in greater patient discomfort and stress. It is well known that this noise is caused by vibration of the gradient coil due to the Lorentz forces generated by the current in the gradient coil, which is placed in a static magnetic field. We have confirmed that MRI noise can be substantially reduced by sealing the gradient coil in a vacuum chamber to block airborne vibration propagation, by supporting the gradient coil independently to block solid vibration propagation and by decreasing the eddy currents induced in RF coils, the RF shield and the static-field-magnet cryostat. Based on these findings, we have developed a silent MRI system in which scanning noise is markedly reduced under a wide range of scanning conditions.
引用
收藏
页码:139 / 144
页数:5
相关论文
共 50 条
  • [1] Quiet MRI with novel acoustic noise reduction
    Katsunuma, A
    Takamori, H
    Sakakura, Y
    Hamamura, Y
    Ogo, Y
    Katayama, R
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03): : 139 - 144
  • [2] A Review on Evolution of Acoustic Noise Reduction in MRI
    Takkar, Manpreet Singh
    Sharma, Manoj Kumar
    Pal, Ravi
    2017 RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2017, : 235 - 240
  • [3] Acoustic noise reduction for spiral MRI by gradient derating
    Zhou, Zeyu
    Alfayad, Abdulrahman
    Chao, Tzu Cheng
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (04) : 1547 - 1554
  • [4] Acoustic noise reduction in a 4 T MRI scanner
    Mechefske, CK
    Geris, R
    Gati, JS
    Rutt, BK
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03) : 172 - 176
  • [5] A Structure Design Method for Reduction of MRI Acoustic Noise
    Nan, Jiaofen
    Zong, Nannan
    Chen, Qiqiang
    Zhang, Liangliang
    Zheng, Qian
    Xia, Yongquan
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [6] Acoustic noise reduction in a 4 T MRI scanner
    Chris K. Mechefske
    Ryan Geris
    Joseph S. Gati
    Brian K. Rutt
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 13 (3) : 172 - 176
  • [7] Evaluation of an Independent Linear Model for Acoustic Noise on a Conventional MRI Scanner and Implications for Acoustic Noise Reduction
    Wu, Ziyue
    Kim, Yoon-Chul
    Khoo, Michael C. K.
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1613 - 1620
  • [8] Acoustic Noise Reduction of Echo Planar Imaging in Diffusion MRI
    Zhao, Junwei
    Lin, Zhenliang
    Zhou, Xiaodong
    Li, Guobin
    Luo, Jie
    ICBBE 2019: 2019 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, 2019, : 33 - 38
  • [9] MRI acoustic noise
    Sellers, MB
    Pavlidis, JD
    Carlberger, T
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1996, 2 (06): : 549 - 560
  • [10] Acoustic noise reduction in MRI using Silent Scan: an initial experience
    Alibek, Sedat
    Vogel, Mika
    Sun, Wei
    Winkler, David
    Baker, Christopher A.
    Burke, Michael
    Gloger, Hubertus
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (04) : 360 - 363