Development of technical solutions for optimizing the hydraulic and thermal process circuits of the P-90 heat-recovery boiler used as part of the PGU-450T combined-cycle plant at the severozapadnaya cogeneration station

被引:0
|
作者
I. I. Belyakov
V. I. Breus
A. B. Barannikov
机构
[1] OAO NPO Central Boiler-Turbine Institute,
关键词
Steam Turbine; Cogeneration Station; Combine Cycle Power Plant; Heat Recovery Boiler; Steam Output;
D O I
10.1134/S0040601512030019
中图分类号
学科分类号
摘要
Results from work on analyzing the performance of the P-90 heat-recovery boilers used as part of the PGU-450T-based Unit 1 at the Severozapadnaya cogeneration station and on revealing factors causing damage to the bends of evaporating tubes are presented. Technical solutions using which a V-94.2 gas turbine can be replaced by a GTE-160 gas turbine are considered.
引用
收藏
页码:183 / 188
页数:5
相关论文