AI-based diagnosis of nuclear cataract from slit-lamp videos

被引:0
|
作者
Eisuke Shimizu
Makoto Tanji
Shintato Nakayama
Toshiki Ishikawa
Naomichi Agata
Ryota Yokoiwa
Hiroki Nishimura
Rohan Jeetendra Khemlani
Shinri Sato
Akiko Hanyuda
Yasunori Sato
机构
[1] OUI Inc.,Department of Ophthalmology
[2] Keio University School of Medicine,Department of Preventive Medicine and Public Health, School of Medicine
[3] Yokohama Keiai Eye Clinic,undefined
[4] Keio University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In ophthalmology, the availability of many fundus photographs and optical coherence tomography images has spurred consideration of using artificial intelligence (AI) for diagnosing retinal and optic nerve disorders. However, AI application for diagnosing anterior segment eye conditions remains unfeasible due to limited standardized images and analysis models. We addressed this limitation by augmenting the quantity of standardized optical images using a video-recordable slit-lamp device. We then investigated whether our proposed machine learning (ML) AI algorithm could accurately diagnose cataracts from videos recorded with this device. We collected 206,574 cataract frames from 1812 cataract eye videos. Ophthalmologists graded the nuclear cataracts (NUCs) using the cataract grading scale of the World Health Organization. These gradings were used to train and validate an ML algorithm. A validation dataset was used to compare the NUC diagnosis and grading of AI and ophthalmologists. The results of individual cataract gradings were: NUC 0: area under the curve (AUC) = 0.967; NUC 1: AUC = 0.928; NUC 2: AUC = 0.923; and NUC 3: AUC = 0.949. Our ML-based cataract diagnostic model achieved performance comparable to a conventional device, presenting a promising and accurate auto diagnostic AI tool.
引用
收藏
相关论文
共 50 条
  • [1] AI-based diagnosis of nuclear cataract from slit-lamp videos
    Shimizu, Eisuke
    Tanji, Makoto
    Nakayama, Shintato
    Ishikawa, Toshiki
    Agata, Naomichi
    Yokoiwa, Ryota
    Nishimura, Hiroki
    Khemlani, Rohan Jeetendra
    Sato, Shinri
    Hanyuda, Akiko
    Sato, Yasunori
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Feature Analysis in Slit-lamp Image for Nuclear Cataract Diagnosis
    Li, Huiqi
    Lim, Joo Hwee
    Liu, Jiang
    Wing, Damon
    Wong, Kee
    Wong, Tien Yin
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 253 - 256
  • [3] An Automatic Diagnosis System of Nuclear Cataract Using Slit-lamp Images
    Li, Huiqi
    Lim, Joo Hwee
    Liu, Jiang
    Wong, Damon Wing Kee
    Tan, Ngan Meng
    Lu, Shijian
    Zhang, Zhuo
    Wong, Tien Yin
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3693 - +
  • [4] Unified Diagnosis Framework for Automated Nuclear Cataract Grading Based on Smartphone Slit-Lamp Images
    Hu, Shenming
    Wang, Xiaoting
    Wu, Hong
    Luan, Xinze
    Qi, Peng
    Lin, Yi
    He, Xiangdong
    He, Wei
    IEEE ACCESS, 2020, 8 : 174169 - 174178
  • [5] Fully Deep Learning for Slit-Lamp Photo Based Nuclear Cataract Grading
    Xu, Chaoxi
    Zhu, Xiangjia
    He, Wenwen
    Lu, Yi
    He, Xixi
    Shang, Zongjiang
    Wu, Jun
    Zhang, Keke
    Zhang, Yinglei
    Rong, Xianfang
    Zhao, Zhennan
    Cai, Lei
    Ding, Dayong
    Li, Xirong
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT IV, 2019, 11767 : 513 - 521
  • [6] Evaluation of Nuclear Cataract with Smartphone-Attachable Slit-Lamp Device
    Yazu, Hiroyuki
    Shimizu, Eisuke
    Okuyama, Sho
    Katahira, Takuya
    Aketa, Naohiko
    Yokoiwa, Ryota
    Sato, Yasunori
    Ogawa, Yoko
    Fujishima, Hiroshi
    DIAGNOSTICS, 2020, 10 (08)
  • [7] Validity of a New Computer-Aided Diagnosis Imaging Program to Quantify Nuclear Cataract from Slit-lamp Photographs
    Cheung, Carol Yim-lui
    Li, Huiqi
    Lamoureux, Ecosse L.
    Mitchell, Paul
    Wang, Jie Jin
    Tan, Ava Grace
    Johari, Lily K.
    Liu, Jiang
    Lim, Joo Hwee
    Aung, Tin
    Wong, Tien Yin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1314 - 1319
  • [8] A Computer Assisted Method for Nuclear Cataract Grading From Slit-Lamp Images Using Ranking
    Huang, Wei
    Chan, Kap Luk
    Li, Huiqi
    Lim, Joo Hwee
    Liu, Jiang
    Wong, Tien Yin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (01) : 94 - 107
  • [9] Portable Handheld Slit-Lamp Based on a Smartphone Camera for Cataract Screening
    Hu, Shenming
    Wu, Hong
    Luan, Xinze
    Wang, Zhuoshi
    Adu, Mary
    Wang, Xiaoting
    Yan, Chunhong
    Li, Bo
    Li, Kewang
    Zou, Ying
    Yu, Xiaoya
    He, Xiangdong
    He, Wei
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [10] A comparative study of optical coherence tomography and slit-lamp based grading of cataract
    Mahil, Aman-Deep Singh
    Saunders, Kathryn
    Richardson, Patrick
    Little, Julie-Anne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)