Errors in crack closure measurements caused by flexure test fixture support effects

被引:0
|
作者
S. Johansson
M. E. Fitzpatrick
机构
[1] Division of Engineering Materials,Department of Mechanical Engineering
[2] Open University,Department of Materials Engineering
来源
Experimental Mechanics | 2001年 / 41卷
关键词
Flexural bend testing; fatigue crack closure; back-face strain; strain gage techniques;
D O I
暂无
中图分类号
学科分类号
摘要
Flexural tests are sometimes used for the evaluation of fatigue and fracture properties, especially for thin cross sections such as plate material where compact tension speciments cannot be used, or where material thicness is limited in the direction required for data generation. The method is also useful for evaluation of crack closure provided the force transfer occurs correctly. This paper shows how the influence of incorrect test fixture supports, which are outside the standard testing arrangement for such test specimens, can affect the force-displacement curves as evidenced using the backface strain method. The results show that incorrect test fixture supports may cause deviations in the force-displacement trace as an artifact of the testing conditions. This effect can severely influence crack closure measurements. The effect was also modeled with finite element analysis.
引用
收藏