Retinopathy induced by zinc oxide nanoparticles in rats assessed by micro-computed tomography and histopathology

被引:10
|
作者
Kim Y.H. [1 ]
Kwak K.A. [1 ]
Kim T.S. [2 ]
Seok J.H. [2 ]
Roh H.S. [2 ]
Lee J.-K. [2 ]
Jeong J. [2 ]
Meang E.H. [3 ]
Hong J.-S. [3 ]
Lee Y.S. [4 ]
Kang J.S. [1 ]
机构
[1] Department of Biomedical Laboratory Science, Namseoul University, Cheonan
[2] Toxicological Research Division, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongwon
[3] Health Care Research Laboratory, Korea Testing and Research Institute, Seoul
[4] Department of Health Administration, Namseoul University, Cheonan
关键词
Histopathology; Micro-CT; Nanoparticles; Ocular toxicity; Zinc oxide;
D O I
10.5487/TR.2015.31.2.157
中图分类号
学科分类号
摘要
Nanotechnology has advanced at an extremely rapid pace over the past several years in numerous fields of research. However, the uptake of nanoparticles (NPs) into the body after administration through various routes may pose a risk to human health. In this study, we investigated the potential ocular toxicity of 20- nm, negatively- charged zinc oxide (ZnO) NPs in rats using micro-computed tomography (micro-CT) and histopathological assessment. Animals were divided into four groups as control group, ZnO NPs treatment group (500 mg/kg/day), control recovery group, and ZnO NPs treatment and recovery group. Ocular samples were prepared from animals treated for 90 days (10 males and 10 females, respectively) and from recovery animals (5 males and 5 females, respectively) sacrificed at 14 days after final treatment and were compared to age-matched control animals. Micro-CT analyses represented the deposition and distribution of foreign materials in the eyes of rats treated with ZnO NPs, whereas control animals showed no such findings. X-ray fluorescence spectrometry and energy dispersive spectrometry showed the intraocular foreign materials as zinc in treated rats, whereas control animals showed no zinc signal. Histopathological examination revealed the retinopathy in the eyes of rats treated with ZnO NPs. Neuronal nuclei expression was decreased in neurons of the ganglion cell layer of animals treated with ZnO NPs compared to the control group. Taken together, treatment with 20-nm, negatively-charged ZnO NPs increased retinopathy, associated with local distribution of them in ocular lesions.
引用
收藏
页码:157 / 163
页数:6
相关论文
共 50 条
  • [1] Effects of lithium on extraction socket healing in rats assessed with micro-computed tomography
    Zeng, Yun Ting
    Fu, Bin
    Tang, Guo Hua
    Zhang, Lei
    Qian, Yu Fen
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1335 - 1340
  • [2] Effect of Methotrexate on Collagen-Induced Arthritis Assessed by Micro-Computed Tomography and Histopathological Examination in Female Rats
    Kim, Young Hee
    Kang, Jin Seok
    BIOMOLECULES & THERAPEUTICS, 2015, 23 (02) : 195 - 200
  • [3] Detection of nephrocalcinosis using ultrasonography, micro-computed tomography, and histopathology in cats
    Tang, Pak-Kan
    Geddes, Rebecca F.
    Chang, Yu-Mei
    Jepson, Rosanne E.
    van den Broek, Dirk Hendrik Nicolaas
    Lotter, Nicola
    Elliott, Jonathan
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2024, 38 (03) : 1553 - 1562
  • [4] The influence of alendronate on the healing of extraction sockets of ovariectomized rats assessed by in vivo micro-computed tomography
    Jee, Jeong-Hyun
    Lee, Wan
    Lee, Byung Do
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (02): : E47 - E53
  • [5] ADVANCES IN MICRO-COMPUTED TOMOGRAPHY
    Herzen, Julia
    MATERIALS EVALUATION, 2022, 80 (06) : 10 - 12
  • [6] Effectiveness of rosiglitazone on bleomycin-induced lung fibrosis: Assessed by micro-computed tomography and pathologic scores
    Jin, Gong Yong
    Bok, Se Mi
    Han, Young Min
    Chung, Myung Ja
    Yoon, Kwon-Ha
    Kim, So Ri
    Lee, Yong Chul
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1901 - 1906
  • [7] Effects of preparation techniques on root canal shaping assessed by micro-computed tomography
    Stavileci, Miranda
    Hoxha, Veton
    Goerduysus, Oemer
    Tatar, Ilkan
    Laperre, Kjell
    Hostens, Jeroen
    Kuecuekkaya, Selen
    Berisha, Merita
    MEDICAL SCIENCE MONITOR BASIC RESEARCH, 2013, 19 : 163 - 168
  • [8] Effects of Root Canal Preparation on Apical Geometry Assessed by Micro-Computed Tomography
    Paque, Frank
    Ganahl, Daniel
    Peters, Ove A.
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1056 - 1059
  • [9] Quality of thermoplasticized and single point root fillings assessed by micro-computed tomography
    Somma, F.
    Cretella, G.
    Carotenuto, M.
    Pecci, R.
    Bedini, R.
    De Biasi, M.
    Angerame, D.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) : 362 - 369
  • [10] Long-term macrobioerosion in the Mediterranean Sea assessed by micro-computed tomography
    Faerber, Claudia
    Titschack, Juergen
    Schonberg, Christine Hanna Lydia
    Ehrig, Karsten
    Boos, Karin
    Baum, Daniel
    Illerhaus, Bernhard
    Asgaard, Ulla
    Bromley, Richard Granville
    Freiwald, Andre
    Wisshak, Max
    BIOGEOSCIENCES, 2016, 13 (11) : 3461 - 3474