Particulate Behavior in Subway Airspace

被引:0
|
作者
Jong Ryeul Sohn
Jo-Chun Kim
Min Young Kim
Youn-Suk Son
Young Sunwoo
机构
[1] Konkuk University,Department of Environmental Engineering
[2] Konkuk University,Department of Advanced Technology Fusion
[3] Seoul Metropolitan Government Research Institute of Public Health and Environment,Department of Environmental Health
[4] Korea University,undefined
关键词
Particulate; Subway; PM; Indoor Air Quality;
D O I
10.1007/BF03654890
中图分类号
学科分类号
摘要
The most pivotal approach to improve subway indoor air quality (IAQ) is to examine the emission sources and particulate behavior. Therefore, the main objective of this study is to investigate the particulate behavior in the subway. In order to examine IAQ in the subway, a sampling and measurement campaign was carried out for 35 sites during the summer and winter seasons from May, 2005 to February, 2006. In case of 24 hour measurement, the mean concentrations (PM10-24 hr) of platform and waiting room were 156.18±53.79 μg/m3 and 111.00±53.31 μg/m3. Besides, as a result of 20 hour measurement, the mean concentrations (PM10-20 hr) of platform and waiting room were 146.09±53.71 μg/m3 and 99.08±42.77 μg/m3, respectively. In general, PM10- 24 hr was higher than PM10-20 hr, and both PM concentrations showed a high correlation coefficient (r= 0.803). It was found that the PM2.5 concentration (109.56±28.24 μg/m3) in winter was higher than that (83.66±57.82 μg/m3) in summer.
引用
收藏
页码:54 / 59
页数:5
相关论文
共 50 条
  • [1] Exposure to airborne particulate matter in the subway system
    Martins, Vania
    Moreno, Teresa
    Cruz Minguillon, Maria
    Amato, Fulvio
    de Miguel, Eladio
    Capdevila, Marta
    Querol, Xavier
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 511 : 711 - 722
  • [2] Ventilation strategy for particulate matter control in subway stations
    Song, Jing
    Zhang, Yongzhi
    Huang, Yan
    Wang, Ping
    Yang, Bingqiang
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [3] Assessment of fine particulate matters in the subway system of Istanbul
    Onat, Burcu
    Stakeeva, Baktygul
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (04) : 574 - 583
  • [4] A Study on Characteristics of Particulate Matter in the Seoul Metropolitan Subway
    Jeong, Hye-Seon
    Kim, Suhyang
    Jo, Han-Gi
    Son, Youn-Suk
    Kim, Jo-Chun
    Sunwoo, Young
    EPIDEMIOLOGY, 2011, 22 (01) : S47 - S47
  • [5] The effect of ventilation protocols on airborne particulate matter in subway systems
    Moreno, Teresa
    Reche, Cristina
    Minguillon, Maria Cruz
    Capdevila, Marta
    de Miguel, Eladio
    Querol, Xavier
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 584 : 1317 - 1323
  • [6] AIRSPACE BEHAVIOR MODELING CONSIDERING FLIGHT INTENT
    Zhang, Jin
    Zhang, Chen
    Hu, Minghua
    2009 IEEE/AIAA 28TH DIGITAL AVIONICS SYSTEMS CONFERENCE, VOLS 1-3, 2009, : 1640 - 1649
  • [7] Sources and Characteristics of Particulate Matter in Subway Tunnels in Seoul, Korea
    Lee, Yongil
    Lee, Young-Chul
    Kim, Taesung
    Choi, Jin Seok
    Park, Duckshin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (11)
  • [8] Commuter exposure to particulate matter at underground subway stations in Philadelphia
    Shakya, Kabindra M.
    Saad, Alexander
    Aharonian, Alex
    BUILDING AND ENVIRONMENT, 2020, 186
  • [9] The geography of subway development and commuting behavior
    Wu, Wenjie
    Yun, Yanwen
    Sun, Yeran
    Zhang, Guanglai
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 133
  • [10] Test and Analysis on Air Particulate Matter Concentration of a Subway Station in Chongqing
    Liu, Qing
    Yu, Xiaoping
    Shi, Guobing
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 856 - 862