Diagnostic accuracy of tactile imaging in selecting patients with palpable breast abnormalities: a prospective comparative study

被引:0
|
作者
Marios-Konstantinos Tasoulis
Konstantinos E. Zacharioudakis
Nikitas G. Dimopoulos
Dimitri J. Hadjiminas
机构
[1] Charing Cross Hospital,Breast Surgery Unit
[2] Imperial College Healthcare NHS Trust,undefined
来源
关键词
Tactile imaging; Sensitivity; Specificity; Breast mechanical imaging; Breast cancer;
D O I
暂无
中图分类号
学科分类号
摘要
Unnecessary referrals of patients with breast lumps represent a significant issue, since only a few patients actually have lumps when examined by a breast specialist. Tactile imaging (TI) is a novel modality in breast diagnostics armamentarium. The aim of this study was to assess TI’s diagnostic performance and compare it to clinical breast examination (CBE). This is a prospective, blinded, comparative study of 276 consecutive patients. All patients underwent conventional imaging and tissue sampling if either a radiological or a palpable abnormality was present. Sensitivity, specificity and positive and negative predictive values for CBE and TI were calculated. Radiological findings and final diagnosis based on histology and/or cytology were used as reference standards. Receiver operator characteristic (ROC) curve analysis was also performed for each method. Sensitivity and specificity of TI in detecting radiologically proven abnormalities were 85.5 % and 35 %, respectively. CBE’s sensitivity was 80.3 % and specificity 76 %. In detecting a histopathological entity according to histology/cytology, sensitivity was 88.2 % for TI and 81.6 % for CBE. Specificity was 38.5 % and 85.7 % for TI and CBE, respectively. These results suggest a trend towards higher sensitivity of TI compared to CBE but significantly lower specificity. Subgroup analysis revealed superior sensitivity of TI in detecting a histological entity in pre-menopausal women. However, CBE’s overall performance was superior compared to TI’s according to ROC curve analysis. Although further research is necessary, the use of TI by the primary care physician as a selection tool for referring patients to a breast specialist should be considered especially in pre-menopausal women.
引用
收藏
页码:589 / 598
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of tactile imaging in selecting patients with palpable breast abnormalities: a prospective comparative study
    Tasoulis, Marios-Konstantinos
    Zacharioudakis, Konstantinos E.
    Dimopoulos, Nikitas G.
    Hadjiminas, Dimitri J.
    BREAST CANCER RESEARCH AND TREATMENT, 2014, 147 (03) : 589 - 598
  • [2] Diagnostic Accuracy of Digital Breast Tomosynthesis in the Evaluation of Palpable Breast Abnormalities
    Hawley, Jeffrey R.
    Kang-Chapman, Justine K.
    Bonnet, Sarah E.
    Kerger, Amy L.
    Taylor, Clayton R.
    Erdal, Barbaros S.
    ACADEMIC RADIOLOGY, 2018, 25 (03) : 297 - 304
  • [3] Tactile imaging of palpable breast cancer
    Srikanchana, R
    Wang, Y
    Freedman, M
    Nguyen, CC
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 792 - 800
  • [4] Diagnostic Accuracy of Breast Medical Tactile Examiners (MTEs): A Prospective Pilot Study
    Lux, Michael P.
    Emons, Julius
    Bani, Mayada R.
    Wunderle, Marius
    Sell, Charlotte
    Preuss, Caroline
    Rauh, Claudia
    Jud, Sebastian M.
    Heindl, Felix
    Langemann, Hanna
    Geyer, Thomas
    Brandl, Anna-Lisa
    Hack, Carolin C.
    Adler, Werner
    Schulz-Wendtland, Ruediger
    Beckmann, Matthias W.
    Fasching, Peter A.
    Gass, Paul
    BREAST CARE, 2019, 14 (01) : 41 - 47
  • [5] Tactile mapping of palpable abnormalities for breast cancer diagnosis
    Wang, Y
    Nguyen, C
    Srikanchana, R
    Geng, Z
    Freedman, MT
    ICRA '99: IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, PROCEEDINGS, 1999, : 1305 - 1309
  • [6] Imaging Management of Palpable Breast Abnormalities
    Lehman, Constance D.
    Lee, Amie Y.
    Lee, Christoph I.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (05) : 1142 - 1153
  • [7] The diagnostic accuracy of core biopsy in palpable and non-palpable breast lesions
    Pijnappel, RM
    vanDalen, A
    Rinkes, IHMB
    vandenTweel, JG
    Mali, WPTM
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (02) : 120 - 123
  • [8] Tactile Imaging of an Imbedded Palpable Structure for Breast Cancer Screening
    Chieu Van Nguyen
    Saraf', Ravi F.
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (18) : 16368 - 16374
  • [9] Accuracy of core needle biopsy in the diagnosis of palpable breast masses: a prospective study on 150 consecutive patients
    Gotzinger, P
    Gebhard, B
    Gnant, M
    Rudas, M
    Reiner, A
    Jakesz, R
    CHIRURG, 1998, 69 (10): : 1068 - 1071
  • [10] Prospective evaluation of the value of negative sonographic and mammographic findings in patients with palpable abnormalities of the breast
    Shetty, MK
    Shah, YP
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (11) : 1211 - 1216