Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectral prediction of postmortem interval from vitreous humor samples

被引:0
|
作者
Ji Zhang
Xin Wei
Jiao Huang
Hancheng Lin
Kaifei Deng
Zhengdong Li
Yu Shao
Donghua Zou
Yijiu Chen
Ping Huang
Zhenyuan Wang
机构
[1] Ministry of Justice,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science
[2] Xi’an Jiaotong University,Department of Forensic Pathology
[3] Xuzhou Medical University,Department of Forensic Medicine
来源
关键词
Forensic medicine; Postmortem interval; Fourier transform infrared spectroscopy; Machine learning; Vitreous humor;
D O I
暂无
中图分类号
学科分类号
摘要
Evaluation of postmortem interval (PMI) is of paramount importance to guide criminal investigations, especially when witnesses are not found. However, accurate PMI estimation is a challenging task in the forensic community due to the limitations of existing methods. The study aims to investigate the potential of attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy for predicting PMI based on vitreous humor (VH). VH samples were collected from 72 rabbits in the range of 0–48 h postmortem at a 6-h interval. Their FTIR spectra were normalized by the extended multiplicative signal correction (RMSC) and divided into calibration and validation sets. After analysis of the absorption bands, the Bayesian ridge regression (BRR), support vector regression (SVR), and artificial neural network (ANN) methods were established by the calibration set using a 10-fold cross-validation that was further used to predict the PMI in the validation set. The validity of the models was assessed by a permutation test. The current study demonstrated that multiple macromolecules in the VH samples were reflected in a FTIR spectrum, and the spectral absorption bands at 1313 and 925 cm−1 were highly correlated with PMI. The three models allowed generalization to the validation set due to similar R2 and errors between the calibration and validation tests. The highest accuracy with R2 = 0.983 and error = 2.018 h was achieved by the ANN model in the validation test. The results suggest that ATR-FTIR spectroscopy may be useful for VH analysis in order to predict PMI in the future.
引用
收藏
页码:7611 / 7620
页数:9
相关论文
共 50 条
  • [1] Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectral prediction of postmortem interval from vitreous humor samples
    Zhang, Ji
    Wei, Xin
    Huang, Jiao
    Lin, Hancheng
    Deng, Kaifei
    Li, Zhengdong
    Shao, Yu
    Zou, Donghua
    Chen, Yijiu
    Huang, Ping
    Wang, Zhenyuan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (29) : 7611 - 7620
  • [2] Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectral discrimination of brain tumour severity from serum samples
    Hands, James R.
    Dorling, Konrad M.
    Abel, Peter
    Ashton, Katherine M.
    Brodbelt, Andrew
    Davis, Charles
    Dawson, Timothy
    Jenkinson, Michael D.
    Lea, Robert W.
    Walker, Carol
    Baker, Matthew J.
    JOURNAL OF BIOPHOTONICS, 2014, 7 (3-4) : 189 - 199
  • [3] Historical perspective and modern applications of Attenuated Total Reflectance - Fourier Transform Infrared Spectroscopy (ATR-FTIR)
    Blum, Marc-Michael
    John, Harald
    DRUG TESTING AND ANALYSIS, 2012, 4 (3-4) : 298 - 302
  • [4] EXPLORATORY ANALYSIS APPLIED TO ATTENUATED TOTAL REFLECTANCE FOURIER TRANSFORM INFRARED (ATR-FTIR) OF BIODIESEL/DIESEL BLENDS
    Chiella Ruschel, Carla Felippi
    Huang, Chun Te
    Samios, Dimitrios
    Ferrao, Marco Flores
    QUIMICA NOVA, 2014, 37 (05): : 810 - 815
  • [5] Attenuated Total Reflectance - Fourier Transform Infrared (ATR-FTIR) Spectroscopy: A Tool to Determine Groundnut Seed Quality
    Eevera, T.
    Chinnasamy, G. P.
    Venkatesan, S.
    Navamaniraj, K. Nelson
    Albert, V. Alex
    Anandhan, J.
    LEGUME RESEARCH, 2024, 47 (07) : 1165 - 1171
  • [6] Measuring dermal exposure to pesticide residues with attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy
    Doran, EM
    Yost, MG
    Fenske, RA
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2000, 64 (05) : 666 - 672
  • [7] Measuring Dermal Exposure to Pesticide Residues with Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy
    E. M. Doran
    M. G. Yost
    R. A. Fenske
    Bulletin of Environmental Contamination and Toxicology, 2000, 64 : 666 - 672
  • [8] Forensic classification of lipsticks using attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy
    Kaur, Kiranpreet
    Yadav, Praveen Kumar
    Bumbrah, Gurvinder Singh
    Sharma, Rakesh Mohan
    VIBRATIONAL SPECTROSCOPY, 2020, 110
  • [9] Rapid Quantification of Methamphetamine: Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR) and Chemometrics
    Hughes, Juanita
    Ayoko, Godwin
    Collett, Simon
    Golding, Gary
    PLOS ONE, 2013, 8 (07):
  • [10] Attenuated total reflectance Fourier transform (ATR-FTIR) spectroscopy and chemometrics for organic cinnamon evaluation
    da Silva Bruni, Andressa Rafaella
    Almeida Teodoro de Oliveira, Vitoria Maria
    Tovar Fernandez, Ana Sophia
    Sakai, Otavio Akira
    Marco, Paulo Henrique
    Valderrama, Patricia
    FOOD CHEMISTRY, 2021, 365