A Biodegradable Vascular Coupling Device for End-to-End Anastomosis

被引:0
|
作者
Ryan Brewster
Bruce K. Gale
Himanshu J. Sant
Ken Monson
Jill Shea
Jay Agarwal
机构
[1] University of Utah,Department of Mechanical Engineering
[2] University of Utah,Department of Surgery, School of Medicine
关键词
Anastomosis; Microsurgery; Vascular coupler; Hand suturing;
D O I
暂无
中图分类号
学科分类号
摘要
When performing microsurgeries, the procedure of vascular anastomosis is frequently performed. When executing this procedure, the most widely used method is hand suturing the vessels back together. This process, however, is extremely time consuming (depending on the size and location of the vessel and the experience of the surgeon) and is subject to human error. The vascular coupling device and its accompanying installation tools in this work have been designed and tested to reduce human error and significantly decrease the amount of time required to perform the anastomosis. Tests that were performed on a revised biodegradable vascular coupling device include the time required to complete the anastomosis, a pressure leak test (both open-end and sealed-end), and a tensile test. The coupler was also installed on the carotid arteries of 2 living and 2 cadaver swine. The coupling device was installed in an average of 7 min and 34 s (n = 3), had significantly less leakage than hand sutured anastomoses, and was able to withstand an average tensile force of 8.65 ± 2.55 N (n = 5) before failure.
引用
收藏
页码:715 / 723
页数:8
相关论文
共 50 条
  • [1] A Biodegradable Vascular Coupling Device for End-to-End Anastomosis
    Brewster, Ryan
    Gale, Bruce K.
    Sant, Himanshu J.
    Monson, Ken
    Shea, Jill
    Agarwal, Jay
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (05) : 715 - 723
  • [2] A Novel Vascular Anastomotic Coupling Device for End-to-End Anastomosis of Arteries and Veins
    Azapagic, Azur
    Agarwal, Jayant
    Gale, Bruce
    Li, Huizhong
    Nelson, Samuel
    Shea, Jill
    Sant, Himanshu
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (02) : 542 - 552
  • [3] A Novel Vascular Coupling System for End-to-End Anastomosis
    Huizhong Li
    Bruce K. Gale
    Himanshu Sant
    Jill Shea
    E. David Bell
    Jay Agarwal
    Cardiovascular Engineering and Technology, 2015, 6 : 294 - 302
  • [4] A Novel Vascular Coupling System for End-to-End Anastomosis
    Li, Huizhong
    Gale, Bruce K.
    Sant, Himanshu
    Shea, Jill
    Bell, E. David
    Agarwal, Jay
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2015, 6 (03) : 294 - 302
  • [5] Optimization and Evaluation of a Vascular Coupling Device for End-to-End Anastomosis: A Finite-Element Analysis
    Li, Huizhong
    Agarwal, Jay
    Coats, Brittany
    Gale, Bruce K.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (01):
  • [6] Vascular Coupling System for End-to-End Anastomosis: An In Vivo Pilot Case Report
    Li, Huizhong
    Gale, Bruce
    Shea, Jill
    Sant, Himanshu
    Terry, Christi M.
    Agarwal, Jay
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (01) : 91 - 95
  • [7] Vascular Coupling System for End-to-End Anastomosis: An In Vivo Pilot Case Report
    Huizhong Li
    Bruce Gale
    Jill Shea
    Himanshu Sant
    Christi M. Terry
    Jay Agarwal
    Cardiovascular Engineering and Technology, 2017, 8 : 91 - 95
  • [8] End-to-end vascular anastomosis - An experimental study
    Winslow, N
    Walker, WW
    ANNALS OF SURGERY, 1936, 103 : 959 - 963
  • [9] MICRO-VASCULAR END-TO-END ANASTOMOSIS
    FOGDESTAM, I
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1982, : 45 - 48
  • [10] END-TO-END ANASTOMOSIS
    MARIK, JJ
    ZANUTTA, EU
    INTERNATIONAL JOURNAL OF FERTILITY, 1983, 28 (01) : 29 - 30