The present study was carried out to test the feasibility of proximal right coronary artery (RCA) imaging and to detect proximal RCA narrowing and occlusion by 2D and 3D transthoracic echocardiography in comparison to coronary angiography (CA). Standardised 2D and 3D echocardiography were performed prior to CA in 97 patients with sinus rhythm. The following parameters were determined: the longest longitudinal detectable RCA segment, the minimum and maximum width of the RCA, the area and number of detectable narrowing O50% of the proximal RCA and the correlation between the echocardiographic and angiographic findings. The visualisation of the proximal RCA and the detection of coronary artery narrowing in the proximal RCA are generally possible. Differences in width and area were not statistically significant between 2D and 3D echocardiography, but showed significant differences between echocardiography and CA. For the detection of proximal RCA narrowing, higher sensitivity and specificity values were obtained by 2D than by 3D echocardiography. However, in patients with sufficient image quality 3D echocardiography permits a more detailed visualisation of the anatomical proportions and an en-face view into the RCA ostium. The visualisation of the proximal RCA is feasible and narrowing can be detected by 2D and 3D echocardiography if image quality is sufficient. CA is the gold standard for the detection of coronary artery stenoses. However, the potential of this new approach is clinically important because crucial findings of the proximal RCA can be presumably detected non-invasively prior to CA. © 2015 The authors.
引用
收藏
页码:73 / 79
页数:6
相关论文
共 50 条
  • [1] FAST ONLINE 3D RECONSTRUCTION FROM 2D CORONARY ARTERY ANGIOGRAPHY: FEASIBILITY AND TECHNICAL CHALLENGE
    Habert, S.
    Dahdah, N.
    Cheriet, F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S230 - S230
  • [2] Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography
    Chu, Winnie C. W.
    Mok, Geoffrey C. F.
    Lam, Wynnie W. M.
    Yam, Manching
    Sung, Rita Y. T.
    PEDIATRIC RADIOLOGY, 2006, 36 (11) : 1148 - 1153
  • [3] Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography
    Winnie C. W. Chu
    Geoffrey C. F. Mok
    Wynnie W. M. Lam
    Man-ching Yam
    Rita Y. T. Sung
    Pediatric Radiology, 2006, 36 : 1148 - 1153
  • [4] Intraindividual comparison of 3D coronary MR angiography and coronary CT angiography
    Ozgun, Murat
    Rink, Michael
    Hoffmeier, Andreas
    Botnar, Rene M.
    Heindel, Walter
    Fischbach, Roman
    Maintz, David
    ACADEMIC RADIOLOGY, 2007, 14 (08) : 910 - 916
  • [5] 3D real time dobutamine stress echocardiography vs 2D stress echocardiography at patients with coronary artery disease
    Scislo, P.
    Kochanowski, J.
    Piatkowski, R.
    Kosior, D.
    Opolski, G.
    EUROPEAN HEART JOURNAL, 2005, 26 : 314 - 314
  • [6] Usefulness of real-time 3D dobutamine stress echocardiography for the detection of coronary artery disease: a comparison with 2D dobutamine stress echocardiography
    Ujino, K
    Muro, T
    Watanabe, H
    Sugioka, K
    Otsuka, R
    Hirata, K
    Daimon, M
    Teragaki, M
    Takeuchi, K
    Yoshikawa, J
    EUROPEAN HEART JOURNAL, 2000, 21 : 573 - 573
  • [7] Coronary artery length measurements from 3D angiography: an in vivo comparison with intravascular ultrasound and quantitative coronary angiography
    Sano, K.
    Carlier, S. G.
    Mintz, G. S.
    Kimura, M.
    Mori, K.
    Lansky, A.
    Moses, J. W.
    Leon, M. B.
    EUROPEAN HEART JOURNAL, 2006, 27 : 508 - 508
  • [8] Simultaneous 3D left and right coronary artery vessel wall imaging
    Andrew D Scott
    Jennifer Keegan
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [9] 3D reconstruction of coronary artery using biplane angiography
    Law, AKW
    Zhu, H
    Chan, FHY
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 533 - 536
  • [10] Fusion imaging in chronic coronary artery stenosis by magnetic resonance phosphorus spectroscopy and 3D coronary angiography
    Nahrendorf, M
    Hiller, KH
    Neuberger, T
    Greiser, A
    Köhler, S
    Hu, K
    Ertl, G
    Bauer, WR
    EUROPEAN HEART JOURNAL, 2002, 23 : 175 - 175