A backlighted imaging technique for particle size measurements in two-phase flows

被引:0
|
作者
K. J. Hay
Z.-C. Liu
T. J. Hanratty
机构
[1] Department of Chemical Engineering,
[2] University of Illinois,undefined
[3] Urbana,undefined
[4] IL 61801,undefined
[5] USA,undefined
来源
Experiments in Fluids | 1998年 / 25卷
关键词
Particle Size; Imaging Technique; Water System; Analysis Time; Photography;
D O I
暂无
中图分类号
学科分类号
摘要
 An imaging technique that uses backlighting has been developed to measure drop sizes in annular two-phase flows with small concentrations of drops in the gas phase. Advantages over conventional photography are realized in that data collection and analysis times are shortened considerably, and consistent unbiased results can be expected. A magnification of 1.9 was used to measure drops above 50 μm. A drop size distribution was obtained for an air–water system as a superficial gas velocity of 30 m/s and a liquid flow of 20 g/s. The data are used to substantiate a theory for the rate of deposition.
引用
收藏
页码:226 / 232
页数:6
相关论文
共 50 条
  • [1] A backlighted imaging technique for particle size measurements in two-phase flows
    Hay, KJ
    Liu, ZC
    Hanratty, TJ
    EXPERIMENTS IN FLUIDS, 1998, 25 (03) : 226 - 232
  • [2] Note on particle size measurements in two-phase flows
    Balachandar, R
    Mulpuru, SR
    Ungurian, MH
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (02): : 390 - 397
  • [3] Particle sizing using particle imaging velocimetry for two-phase flows
    Kadambi, JR
    Martin, WT
    Amirthaganesh, S
    Wernet, MP
    POWDER TECHNOLOGY, 1998, 100 (2-3) : 251 - 259
  • [4] Particle imaging technique for size, velocity and concentration measurements in particle laden flows
    Martin, WT
    Kadambi, JR
    Wernet, MP
    OPTICAL TECHNOLOGY IN FLUID, THERMAL, AND COMBUSTION FLOW III, 1997, 3172 : 518 - 529
  • [5] Direct imaging of two-phase flows by electrical impedance measurements
    Seleghim, P
    Hervieu, E
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (09) : 1492 - 1500
  • [6] Effect of particle size and loading on development region in two-phase flows
    Department of Mechanical Engineering, University of Gaziantep, 27310 Gaziantep, Turkey
    Turk. J. Eng. Environ. Sci., 1 (27-37):
  • [7] In-line imaging measurements of particle size, velocity and concentration in a particulate two-phase flow
    Chen, Xiaozhen
    Zhou, Wu
    Cai, Xiaoshu
    Su, Mingxu
    Liu, Hailong
    PARTICUOLOGY, 2014, 13 : 106 - 113
  • [8] In-line imaging measurements of particle size,velocity and concentration in a particulate two-phase flow
    Xiaozhen Chen
    Wu Zhou
    Xiaoshu Cai
    Mingxu Su
    Hailong Liu
    Particuology, 2014, 13 (02) : 106 - 113
  • [9] Phase boundary estimation in two-phase flows with electrical impedance imaging technique
    Jeon, HJ
    Choi, BY
    Kim, MC
    Kim, KY
    Kim, S
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2004, 31 (08) : 1105 - 1114
  • [10] Particle concentration and size measurements in two-phase turbulent coaxial jets
    Fan, JR
    Zhao, H
    Cen, KF
    CHEMICAL ENGINEERING COMMUNICATIONS, 1996, 156 : 115 - 129