Size-exclusion chromatography of cellulose: observations on the low-molar-mass fraction

被引:0
|
作者
Leena Pitkänen
Herbert Sixta
机构
[1] Aalto University,Department of Bioproducts and Biosystems
来源
Cellulose | 2020年 / 27卷
关键词
Size-exclusion chromatography; Cellulose; Cello-oligomers; Oligomeric region; Light-scattering detection;
D O I
暂无
中图分类号
学科分类号
摘要
Accurate determination of molar mass distribution for disperse cellulose samples has proved to be a challenging task. While size-exclusion chromatography coupled to multi-angle light scattering (MALS) and differential refractive index (DRI) detectors has become the most commonly used method for molar mass determination of celluloses, this technique suffers low sensitivity at the low-molar mass range. As discussed here, the universal method for accurate molar mass distribution analysis of cellulose samples not exists and thus thorough understanding on the differences of the various methodological approaches is important. In this study, the focus is in the accurate determination of the low-molar mass fraction. The results obtained by combining the two calibration strategies, MALS/DRI for polymeric region of a cellulose sample and conventional calibration for oligomeric region, was compared to the results obtained using only MALS/DRI (with extrapolation of the curve where signal-to-noise of MALS is low). For birch pulp sample, the results from the two approaches were comparable; it should be highlighted, however, that MALS/DRI slightly overestimates the molar masses at the low-molar-mass region.
引用
收藏
页码:9217 / 9225
页数:8
相关论文
共 50 条
  • [1] Size-exclusion chromatography of cellulose: observations on the low-molar-mass fraction
    Pitkanen, Leena
    Sixta, Herbert
    CELLULOSE, 2020, 27 (16) : 9217 - 9225
  • [2] Molar mass determination of lignins by size-exclusion chromatography: towards standardisation of the method
    Baumberger, Stephanie
    Abaecherli, Alfred
    Fasching, Mario
    Gellerstedt, Goeran
    Gosselink, Richard
    Hortling, Bo
    Li, Jiebing
    Saake, Bodo
    de Jong, Ed
    HOLZFORSCHUNG, 2007, 61 (04) : 459 - 468
  • [3] Application of size-exclusion chromatography to polymers of ultra-high molar mass
    Aust, N
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2003, 56 (1-3): : 323 - 334
  • [4] OBSERVATIONS ON THE RAPID SIZE-EXCLUSION CHROMATOGRAPHY OF PROTEINS
    BARFORD, RA
    SLIWINSKI, BJ
    ROTHBART, HL
    CHROMATOGRAPHIA, 1979, 12 (05) : 285 - 288
  • [5] POLY 108-Degradation of ultrahigh molar mass polymers in size-exclusion chromatography
    Striegel, Andre M.
    Isenberg, Samantha L.
    Cote, Gregory L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [6] SIZE-EXCLUSION CHROMATOGRAPHY
    BARTH, HG
    BOYES, BE
    JACKSON, C
    ANALYTICAL CHEMISTRY, 1994, 66 (12) : R595 - R620
  • [7] SIZE-EXCLUSION CHROMATOGRAPHY AND MASS-SPECTROMETRY OF PHOTOGRAPHIC BASES IN CELLULOSE NITRATE DEGRADATION
    LOUVET, A
    LAVEDRINE, B
    FLIEDER, F
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1995, 43 (01): : 30 - 35
  • [8] On-line size-exclusion chromatography/mass spectrometry of low molecular mass heparin
    Henriksen, J
    Ringborg, LH
    Roepstorrf, P
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (11): : 1305 - 1312
  • [9] COPOLYMER CHARACTERIZATION USING CONVENTIONAL SIZE-EXCLUSION CHROMATOGRAPHY AND MOLAR-MASS-SENSITIVE DETECTORS
    GORES, F
    KILZ, P
    ACS SYMPOSIUM SERIES, 1993, 521 : 122 - 148
  • [10] Molar-mass characterization of cationic polymers for gene delivery by aqueous size-exclusion chromatography
    Jiang, XL
    van der Horst, A
    van Steenbergen, MJ
    Akeroyd, N
    van Nostrum, CF
    Schoenmakers, PJ
    Hennink, WE
    PHARMACEUTICAL RESEARCH, 2006, 23 (03) : 595 - 603