摘要
An experimental study was performed to measure the regionally averaged heat-transfer distributions in a rotating ribbed channel with an aspect ratio of 4:1. The Reynolds number, based on hydraulic diameter, varies from 5 x 10(3) to 40 x 10(3). The rotation number ranges from 0 to 0.3, and the inlet coolant-to-wall density ratio (Deltap/p) is maintained around 0.122. Six different configurations of ribs, oriented at an angle of 45 deg to the direction of flow, are placed on both the leading and trailing surfaces: 1) parallel V-shaped ribs without gaps, 2) staggered V-shaped ribs without gaps, 3) parallel V-shaped ribs with gaps, 4) parallel angled ribs without gaps, 5) staggered angled ribs without gaps, and 6) parallel angled ribs with gaps. The rib-height-to-hydraulic-diameter ratio (e/D-h) is 0.078, and the rib-pitch-to-height ratio (P/e) is 10. The channel orientation with-respect to the plane of rotation is 135 deg. The results show that the V-shaped rib configuration produces more heat-transfer enhancement than the angled rib configurations. It is also shown that there is only a negligible difference between the heat-transfer enhancement due to the staggered V-shaped ribs without gaps and the enhancement due to the parallel V-shaped ribs without gaps. The same is true for the staggered and parallel angled ribs without gaps. Also, the parallel V-shaped ribs without gaps produce more heat-transfer enhancement than the V-shaped ribs with gaps, whereas the parallel angled ribs with gaps produce more beat-transfer enhancement than the angled ribs without gaps., Finally, rotation further increases the heat transfer from all surfaces above that of the stationary channels.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 50 条
  • [1] Flow and heat-transfer computations in rotating rectangular channels with V-shaped ribs
    Su, GG
    Teng, SY
    Chen, HC
    Han, JC
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2004, 18 (04) : 534 - 547
  • [2] Heat transfer in rectangular channels with transverse and V-shaped broken ribs
    Tanda, G
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) : 229 - 243
  • [3] Heat Transfer Augmentation in Rotating Triangular Channels with Discrete and V-Shaped Ribs
    Liu, Yao-Hsien
    Lai, Shi-Yu
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (04) : 603 - 611
  • [4] AUGMENTED HEAT-TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS
    HAN, JC
    ZHANG, YM
    LEE, CP
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (03): : 590 - 596
  • [5] Heat transfer distribution in rectangular ducts with V-shaped ribs
    Gao, X
    Sundén, B
    HEAT AND MASS TRANSFER, 2001, 37 (4-5) : 315 - 320
  • [6] Heat transfer distribution in rectangular ducts with V-shaped ribs
    X. Gao
    B. Sundén
    Heat and Mass Transfer, 2001, 37 : 315 - 320
  • [7] Heat transfer in rotating rectangular cooling channels (AR=4) with angled ribs
    Griffith, TS
    Al-Hadhrami, L
    Han, JC
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 617 - 625
  • [8] Thermal performance of angled, V-shaped and leaning-V-shaped ribs in a rotating rectangular channel with 45° orientation
    Wang, Jinsheng
    Luo, Lei
    Wang, Lei
    Sunden, Bengt Ake
    Wang, Songtao
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2018, 28 (03) : 661 - 683
  • [9] Experimental heat transfer and friction in channels roughened with angled, V-shaped, and discrete ribs on two opposite walls
    Taslim, ME
    Li, T
    Kercher, DM
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1996, 118 (01): : 20 - 28
  • [10] Numerical study on heat transfer enhancement in a rectangular duct with V-shaped ribs
    Sriromreun P.
    Sriromreun P.
    Chemical Engineering Transactions, 2018, 70 : 1285 - 1290