Intrinsic Passive Stiffness of 2 Constructs of Varus Proximal Femoral Osteotomy: External Fixator or Blade Plate

被引:2
|
作者
Paliobeis, Christos P. [1 ]
Kanellopoulos, Anastasios D. [1 ]
Babis, George C. [1 ]
Magnissalis, Evangelos A. [2 ]
Catling, Jonathan C. [3 ]
Papagelopoulos, Panayiotis J. [1 ]
Soucacos, Panayotis N. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Orthopaed Surg 1, Birmingham B30 1SU, W Midlands, England
[2] Univ Athens, KAT Hosp Kifissia, Lab Res Musculoskeletal Syst, Athens, Greece
[3] Univ Worcester, Worcester, MA USA
关键词
external fixator; proximal femoral osteotomy; varus intertrochanteric osteotomy; biomechanics; hip dysplasia; PEDIATRIC NEUROMUSCULAR POPULATION; HIP SCREW; PERTROCHANTERIC FRACTURES; GREATER TROCHANTER; EPIPHYSEODESIS; EPIPHYSIS; NECROSIS; GROWTH; FEMUR;
D O I
10.1097/BPO.0b013e3181d8fa53
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Despite the published clinical evidence of the implementation of external fixation of proximal femoral osteotomies, there is lack of specific laboratory justification. Methods: Two groups of 5 adult composite femur constructs of varus proximal femoral osteotomy were tested under incremental and cyclical loading of up to 600N along the mechanical axis. Five were fixed with a blade plate and another 5 with a monolateral external fixator. Load versus displacement curves were produced, and passive stiffness of all constructs was calculated. The described loading regime aimed to simulate the initial postoperative state and provide data for the assessment of vertical intrinsic passive stiffness in partial weight-bearing conditions. Results: Although the blade plate constructs showed higher average stiffness, this was not statistically significant [F(1,8) = 1.712, P = 0.23]. No construct failed. No failure or plastic deformation was observed under the described loading regime. Conclusions: Vertical intrinsic passive stiffness in partial weight-bearing conditions during the initial postoperative period can be considered satisfactory subsequent to unilateral external fixation of a varus intertrochanteric osteotomy.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 15 条
  • [1] CANNULATED BLADE PLATE FOR PROXIMAL FEMORAL VARUS OSTEOTOMY
    GRANT, AD
    LEHMAN, WB
    STRONGWATER, AM
    ATAR, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (259) : 111 - 113
  • [2] Blade plate versus locking plate fixation of proximal femoral varus osteotomy in children with cerebral palsy
    Oladeji, Afolayan K.
    Cummings, Jason
    Minaie, Arya
    Landau, Andrew J.
    Gordon, Joe Eric
    Hosseinzadeh, Pooya
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2023, 32 (01): : 72 - 79
  • [3] Implant-related Fractures in Children With Proximal Femoral Osteotomy: Blade Plate Versus Screw-side Plate Constructs
    Jain, Amit
    Thompson, John M.
    Brooks, Jaysson T.
    Ain, Michael C.
    Sponseller, Paul D.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (01) : E1 - E5
  • [4] Three-dimensionally corrective external fixator system for proximal femoral osteotomy
    Ito, H
    Minami, A
    Suzuki, K
    Matsuno, T
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2001, 21 (05) : 652 - 656
  • [5] PROXIMAL FEMORAL OSTEOTOMY USING THE AO FIXED-ANGLE BLADE PLATE
    BEAUCHESNE, R
    MILLER, F
    MOSELEY, C
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1992, 12 (06) : 735 - 740
  • [6] Augmented Blade Plate Fixation of a Varus Derotation Osteotomy of the Proximal Femur Using a Tension Band
    Zampini, Jay
    McCarthy, James J.
    ORTHOPEDICS, 2009, 32 (06) : 414 - 417
  • [7] Unilateral uniplanar modular external fixator for percutaneous proximal femoral osteotomy in children: surgical technique
    Coppa, Valentino
    Marinelli, Mario
    Specchia, Nicola
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (01): : 205 - 211
  • [8] Unilateral uniplanar modular external fixator for percutaneous proximal femoral osteotomy in children: surgical technique
    Valentino Coppa
    Mario Marinelli
    Nicola Specchia
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 205 - 211
  • [9] Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures
    Huan Su
    Siyang Zhong
    Tianyong Ma
    Weidong Wu
    Yihong Lu
    Dewei Wang
    BMC Musculoskeletal Disorders, 24
  • [10] Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures
    Su, Huan
    Zhong, Siyang
    Ma, Tianyong
    Wu, Weidong
    Lu, Yihong
    Wang, Dewei
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)