Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography

被引:48
|
作者
Boverman, Gregory [1 ]
Fang, Qianqian
Carp, Stefan A.
Miller, Eric L.
Brooks, Dana H.
Selb, Juliette
Moore, Richard H.
Kopans, Daniel B.
Boas, David A.
机构
[1] Rensselaer Polytech Inst, Dept Biomed Engn, Jonsson Engn Ctr, Troy, NY 12180 USA
[2] Massachusetts Gen Hosp, Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Tufts Univ, Dept Elect & Comp Engn, Medford, MA 02153 USA
[4] Northeastern Univ, Dept Elect & Comp Engn, Boston, MA 02115 USA
[5] Massachusetts Gen Hosp, Breast Imaging Ctr, Boston, MA 02114 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 12期
关键词
D O I
10.1088/0031-9155/52/12/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatiotemporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.
引用
收藏
页码:3619 / 3641
页数:23
相关论文
共 50 条
  • [1] Spatio-temporal imaging of vascular reactivity by optical tomography
    Barbour, RL
    Graber, HL
    Schmitz, CH
    Pei, YL
    Zhong, S
    Barbour, SLS
    Blattman, S
    Panetta, T
    PROCEEDINGS OF INTER-INSTITUTE WORKSHOP ON IN VIVO OPTICAL IMAGING AT THE NIH, 2000, : 161 - 166
  • [2] A haemodynamic response function model in spatio-temporal diffuse optical tomography
    Zhang, YH
    Brooks, DH
    Boas, DA
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19): : 4625 - 4644
  • [3] A spatio-temporal reconstruction algorithm for Diffuse Optical Tomography based on a hemodynamic response function model
    Zhang, Yiheng
    Brooks, Dana H.
    Boas, David A.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1292 - +
  • [4] Optical projection tomography for spatio-temporal analysis in the zebrafish
    Bryson-Richardson, RJ
    Currie, PD
    ZEBRAFISH: 2ND EDITION CELLULAR AND DEVELOPMENTAL BIOLOGY, 2004, 76 : 37 - +
  • [5] Spatio-temporal optical coherence tomography provides full thickness imaging of the chorioretinal complex
    Auksorius, Egidijus
    Borycki, Dawid
    Wegrzyn, Piotr
    Sikorski, Bartosz L.
    Lizewski, Kamil
    Zickiene, Ieva
    Rapolu, Mounika
    Adomavicius, Karolis
    Tomczewski, Slawomir
    Wojtkowski, Maciej
    ISCIENCE, 2022, 25 (12)
  • [6] Spatio-Temporal Optical Coherence Tomography STOC-T for in vivo retinal imaging
    Auksorius, Egidijus
    Wegrzyn, Piotr
    Zickiene, Ieva
    Tomczewski, Slawomir
    Adomavicius, Karolis
    Lizewski, Kamil
    Borycki, Dawid
    Wojtkowski, Maciej
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA IV, 2021, 11924
  • [7] Beneficial techniques for spatio-temporal imaging in electrical impedance tomography
    Boyle, Alistair
    Aristovich, Kirill
    Adler, Andy
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (06)
  • [8] Optical coherence tomography by spatio-temporal joint transform correlator
    Yasuno, Y
    Nakama, M
    Sutoh, Y
    Yoshikawa, N
    Itoh, M
    Yatagai, T
    Mori, M
    APPLICATIONS OF PHOTONIC TECHNOLOGY 4: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2000, 4087 : 1282 - 1285
  • [9] Spatio-temporal compressed quantitative acoustic microscopy
    Kim, J-H.
    Mamou, J.
    Kouame, D.
    Achim, A.
    Basarab, A.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1156 - 1159
  • [10] Spatio-Temporal Quantitative Ultrasound Imaging for Breast Cancer Identification
    Oh, Seok-Hwan
    Kim, Myeong-Gee
    Kim, Young-Min
    Jung, Guil
    Kwon, Hyuksool
    Bae, Hyeon-Min
    Proceedings - International Symposium on Biomedical Imaging, 2023, 2023-April