Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer films

被引:83
|
作者
Betts, TA
Tipple, CA
Sepaniak, MJ [1 ]
Datskos, PG
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37919 USA
[2] Kutztown State Univ, Dept Phys Sci, Kutztown, PA 19530 USA
[3] Oak Ridge Natl Lab, Engn Technol Div, Oak Ridge, TN 37831 USA
基金
美国国家科学基金会;
关键词
micro-cantilevers; chemical sensors; thin polymer films;
D O I
10.1016/S0003-2670(00)01062-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In an effort to impart selectivity to chemical sensors based on micro-machined silicon cantilevers, thin films of polymeric chromatographic stationary phases (SP-2340 and OV-25) were applied to one side of the cantilever surface using a spin coating procedure. These coatings influenced the response of the micro-cantilever to vapor phase test analytes of varying chemical compositions. For the SP-2340 coated micro-cantilevers, the effects of both polymeric film thickness and cantilever structure thickness on response characteristics were investigated. Sensitivity improved as both film thickness and cantilever leg thickness were decreased. The selectivity, as indicated by differences in relative responses to the test analytes, were different for the two phases which differed significantly in polarity. The SP-2340 coated cantilevers exhibited response characteristics that an fairly similar to that expected for adsorption of the test analytes onto silica. Responses are shown to be proportional to analyte concentration. Response characteristics are shown to be consistent with predictions based on a gas chromatographic stationary phase classification scheme. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 50 条
  • [1] Micro-cantilevers for thin films Young's modulus
    McShane, G. J.
    Boutchich, M.
    Phani, S.
    Moore, D. F.
    Lu, T. J.
    IUTAM SYMPOSIUM ON MECHANICAL BEHAVIOR AND MICRO-MECHANICS OF NANOSTRUCTURED MATERIALS, 2007, 144 : 71 - +
  • [2] A new approach to integrate PLZT thin films with micro-cantilevers
    Singh, Ravindra
    Goel, T. C.
    Chandra, Sudhir
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2009, 34 (04): : 563 - 572
  • [3] A new approach to integrate PLZT thin films with micro-cantilevers
    Ravindra Singh
    T. C. Goel
    Sudhir Chandra
    Sadhana, 2009, 34 : 563 - 572
  • [4] A facile approach to fabricate ZnO thin film based micro-cantilevers
    Joshi, Priyanka
    Singh, Jitendra
    Sharma, Ramakant
    Jain, V. K.
    Akhtar, Jamil
    MICROELECTRONIC ENGINEERING, 2018, 187 : 50 - 57
  • [5] On the use of shape memory alloy thin films to tune the dynamic response of micro-cantilevers
    Kniknie, T.
    Bellouard, Y.
    Homburg, E.
    Nijmeijer, H.
    Wang, X.
    Vlassak, J. J.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (01)
  • [6] Thermal noise measurements on micro-cantilevers coated with dielectric materials
    Cagnoli, Gianpietro
    Dolique, Vincent
    Degallaix, Jerome
    Flaminio, Raffaele
    Forest, Daniele
    Granata, Massimo
    Michel, Christophe
    Morgado, Nazario
    Pinard, Laurent
    Aguilar, Felipe
    Li, Tianjun
    Geitner, Mickael
    Bellon, Ludovic
    2013 22ND INTERNATIONAL CONFERENCE ON NOISE AND FLUCTUATIONS (ICNF), 2013,
  • [7] Development of a sensor device with polymer-coated piezoelectric micro-cantilevers for detection of volatile organic compounds
    Ahmed, Waqar M.
    Steenwelle, Ruud J. A.
    Knobel, Hugo H.
    Davie, Alan
    Steijvers, Ron
    Verhoeckx, Fred
    Goodacre, Royston
    Fowler, Stephen J.
    Rijnders, A. J. H. M.
    Nijsen, Tamara M.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (03)
  • [8] NiTi shape memory alloy thin film micro-cantilevers array
    Chung, C. Y.
    Chan, P. M.
    THIN SOLID FILMS, 2011, 519 (15) : 5307 - 5309
  • [9] Comparing silicon and diamond micro-cantilevers based sensors for detection of added mass and stiffness changes
    Possas, M.
    Rousseau, L.
    Ghassemi, F.
    Lissorgues, G.
    Gonzales, P.
    Scorsone, E.
    Bergonzo, P.
    EUROSENSORS 2015, 2015, 120 : 1115 - 1119
  • [10] Measurement of DNA denaturation on B-NCD coated diamond micro-cantilevers
    Bongrain, A.
    Uetsuka, H.
    Rousseau, L.
    Valbin, L.
    Saada, S.
    Gesset, C.
    Scorsone, E.
    Lissorgues, G.
    Bergonzo, P.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2010, 207 (09): : 2078 - 2083