Effect of ice thickness and snow cover depth on performance optimization of ground source heat pump based on the energy, exergy, economic and environmental analysis

被引:29
作者
Nikitin, Andrey [1 ]
Farahnak, Mehdi [2 ]
Deymi-Dashtebayaz, Mahdi [1 ]
Muraveinikov, Sergei [1 ]
Nikitina, Veronika [1 ]
Nazeri, Reza [3 ]
机构
[1] ITMO Univ, Fac Cryogen Engn, St Petersburg, Russia
[2] Isfahan Univ Technol, Dept Mech Engn, Esfahan, Iran
[3] Hakim Sabzevari Univ, Ctr Computat Energy, Dept Mech Engn, Sabzevar, Iran
关键词
Ground source heat pump (GSHP); Soil depth; Snow and ice; Coefficient of performance (COP); Exergoeconomic and environmental analysis; Optimization; SOIL-TEMPERATURE; SYSTEM; EXCHANGER; MODEL; WATER;
D O I
10.1016/j.renene.2021.12.132
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, due to the use of renewable energy such as geothermal and capability of reduction of energy consumption and greenhouse gas emissions by ground source heat pumps, these heat pump cycles have attracted considerable attention as a green energy system. The variations in temperature of soil play an important role in efficiency of ground source heat pump cycles which is determined by some effective parameters such as ambient temperature, soil type and depth. Besides, in cold regions where the ground is covered by snow and ice at least part of the year, the factors like the temperature and thickness of snow and ice layer are also effective on soil temperature. Therefore, this paper investigates the effects of variations of soil temperature on performance of ground source heat pump at different soil depths of 20 cm, 50 cm and 100 cm which are covered by 0 cm-50 cm of ice and 0 cm-40 cm of snow where the temperature of air ranges from-40 & DEG;C to 0 & DEG;C. The study is divided into two parts including the heat transfer analysis in soil covered with snow and ice using computational fluid dynamics and thermo-economic-environmental analysis of a proposed cascade ground source heat pump system. The proposed cascade heat pump cycle is operated using R41-R161 refrigerant pair as low global warming potential and zero ozone depletion potential working fluids. The continuity, Brinkman momentum and energy equations are firstly employed as governing equations for computational analysis to obtain the soil temperature profile. Then, the energy-exergy-economic-environmental analysis is performed to optimize the performance of the cascade ground source heat pump system based on the soil temperature profiles obtained from the previous step using Pareto-based multi-objective optimization method. Optimization results show that there is an optimal operating point for the proposed cascade ground source heat pump system where the maximum coefficient of performance of 3.2, maximum exergy efficiency of 64% and minimum total cost rate of 10300 $/year are obtained. Finally, the optimal soil depth and evaporator temperature are determined for different snow and ice thicknesses at different weather conditions. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1301 / 1317
页数:17
相关论文
共 47 条
  • [1] [Anonymous], 2013, P ASME 2013 INT MECH
  • [2] Evaluation of the performance of a ground-source heat-pump system with series GHE (ground heat exchanger) in the cold climate region
    Bakirci, Kadir
    [J]. ENERGY, 2010, 35 (07) : 3088 - 3096
  • [3] Greenhouse gas emission savings of ground source heat pump systems in Europe: A review
    Bayer, Peter
    Saner, Dominik
    Bolay, Stephan
    Rybach, Ladislaus
    Blum, Philipp
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (02) : 1256 - 1267
  • [4] Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany
    Blum, Philipp
    Campillo, Gisela
    Koelbel, Thomas
    [J]. ENERGY, 2011, 36 (05) : 3002 - 3011
  • [5] The Use of Ground Source Heat Pump to Achieve a Net Zero Energy Building
    D'Agostino, Diana
    Mele, Luigi
    Minichiello, Francesco
    Renno, Carlo
    [J]. ENERGIES, 2020, 13 (13)
  • [6] Modeling of a novel nanofluid-based concentrated photovoltaic thermal system coupled with a heat pump cycle (CPVT-HP)
    Deymi-Dashtebayaz, Mahdi
    Rezapour, Mojtaba
    Farahnak, Mehdi
    [J]. APPLIED THERMAL ENGINEERING, 2022, 201
  • [7] Energy, exergoeconomic and environmental optimization of a cascade refrigeration system using different low GWP refrigerants
    Deymi-Dashtebayaz, Mahdi
    Sulin, Alexander
    Ryabova, Tatyana
    Sankina, Iuliia
    Farahnak, Mehdi
    Nazeri, Reza
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (06):
  • [8] Using the potential of energy losses in gas pressure reduction stations for producing power and fresh water
    Deymi-Dashtebayaz, Mahdi
    Dadpour, Daryoush
    Khadem, Javad
    [J]. DESALINATION, 2021, 497 (497)
  • [9] Investigation of the effect of using various HFC refrigerants in geothermal heat pump with residential heating applications
    Deymi-Dashtebayaz, Mahdi
    Maddah, Saeed
    Goodarzi, Marjan
    Maddah, Omid
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) : 361 - 372
  • [10] Multi objective optimization of using the surplus low pressure steam from natural gas refinery in the thermal desalination process
    Deymi-Dashtebayaz, Mahdi
    Tayyeban, Edris
    [J]. JOURNAL OF CLEANER PRODUCTION, 2019, 238