ABAQUS software was first used to study the structure behaviour of steel-to-concrete connection by post-installed anchorage under cyclic loading. Three types of embedment depth 25d, 20d and 15d were considered. Based on previous simulation results of earthquake and fire, it can be concluded that the seismic performance of steel-to-concrete connection by post-installed anchorage is strongly related to the rotation angle. of steel beam. The heat analysis results indicate that the fire resistance of post-installed connection after 2 hours exposure could meet the requirement of related codes. Based on the simulation results mentioned above, a performance-based design conception with four performance levels has been provided to guarantee structure safety under the combined action of earthquake and fire. According to the principle of performance-based methodology, rotation angle. of steel beam and fire resistance rating T are chosen as critical index for performance evaluation. Among the 4 levels of performance, Level 1 has the highest specification for disaster protection. To achieve the performance level 1, the thickness of fire protection layer should not be less than 45 mm, and the embedment depth should be 25d at least.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Post-earthquake fire behaviour of steel-to-concrete joints using post-installed anchorages
    Xie, Qun
    Xue, Song
    Xu, Lei
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 174 (02) : 117 - 131
  • [2] INFLUENCE ON THE LOAD-DISPLACEMENT BEHAVIOUR OF STEEL-TO-CONCRETE CONNECTIONS WITH POST-INSTALLED ADHESIVE ANCHORS
    Maçi, Nilde
    Hofmann, Jan
    ce/papers, 2023, 6 (01): : 471 - 481
  • [3] Study on Seismic Damage Model of Post-installed Connection Between Steel and Concrete
    Xie, Qun
    Xue, Song
    Xu, Lei
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (9A) : 1201 - 1211
  • [4] Study on Seismic Damage Model of Post-installed Connection Between Steel and Concrete
    Qun Xie
    Song Xue
    Lei Xu
    International Journal of Civil Engineering, 2018, 16 : 1201 - 1211
  • [5] Performance and design of post-installed large diameter anchors in concrete
    Wang, Dongpo
    Wu, Dongsheng
    Ouyang, Chaojun
    Zhai, Mingang
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 114 : 142 - 150
  • [6] Post-earthquake fire behavior and performance-based fire design of steel moment frame buildings
    Alasiri, Muhannad R.
    Chicchi, Rachel
    Varma, Amit H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177 (177)
  • [7] The Behavior of Post-installed Rebar Connectors in Steel Frame Retrofitted Concrete Structures Under Combined Shear and Tension
    Zeng, Rong
    Bao, En-He
    Yin, Xia
    Fu, Feng
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2024, 18 (01)
  • [8] Post-earthquake fire performance-based behavior of reinforced concrete structures
    Behnam, Behrouz
    Ronagh, Hamid R.
    EARTHQUAKES AND STRUCTURES, 2013, 5 (04) : 379 - 394
  • [9] Mechanical behavior of post-installed anchorage between steel and concrete under high temperature
    Xue, Song
    Xie, Qun
    Guan, Ping-ping
    PROCEEDINGS OF THE 2017 3RD INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS (IFEESM 2017), 2017, 120 : 16 - 20
  • [10] Design Recommendations for Concrete Pryout Capacity of Headed Steel Studs and Post-Installed Anchors
    Jebara, Khalil
    Sharma, Akanshu
    Ozbolt, Josko
    CIVILENG, 2023, 4 (03): : 782 - 807