This paper presents a method of X-ray image acquisition for the high-resolution tomography reconstruction that uses a light source of synchrotron radiation to reconstruct a three-dimensional tomographic volume dataset for a nanoscale object. For large objects, because of the limited field-of-view, a projection image of an object should to be taken by several shots from different locations, and using an image stitching method to combine these image blocks together. In this study, the overlap of image blocks should be small because our light source is the synchrotron radiation and the X-ray dosage should be minimized as possible. We use the properties of synchrotron radiation to enable the image stitching and alignment success when the overlaps between adjacent image blocks are small. In this study, the size of overlaps can reach to 15% of the size of each image block. During the reconstruction, the mechanical stability should be considered because it leads the misalignment problem in tomography. We adopt the feature-based alignment method to solve this problem. Finally, we apply the proposed method for a kidney of mouse for verification.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Calibration of high-resolution X-ray tomography with atomic force microscopy
    Kalukin, AR
    Winn, B
    Wang, YX
    Jacobsen, C
    Levine, ZH
    Fu, J
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2000, 105 (06): : 867 - 874
  • [2] High-resolution compact X-ray microscopy
    Takman, P. A. C.
    Stollberg, H.
    Johansson, G. A.
    Holmberg, A.
    Lindblom, M.
    Hertz, H. M.
    JOURNAL OF MICROSCOPY, 2007, 226 (02) : 175 - 181
  • [3] HIGH-RESOLUTION X-RAY PROJECTION MICROSCOPY
    NIXON, WC
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1955, 232 (1191): : 475 - &
  • [4] HIGH-RESOLUTION LARGE-VOLUME MICROSCOPY WITH LOW-SPATIAL-FREQUENCY HOLOGRAMS
    ANDERSON, WL
    BEISSNER, RE
    BOND, RL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1970, 60 (05) : 715 - &
  • [5] High-resolution X-ray microscopy for biological objects
    Kochubey, VI
    Gyunsburg, KE
    Zvezdova, NP
    Gorin, GB
    Sedova, YG
    SARATOV FALL MEETING '98: LIGHT SCATTERING TECHNOLOGIES FOR MECHANICS, BIOMEDICINE, AND MATERIAL SCIENCE, 1999, 3726 : 58 - 61
  • [6] High-resolution scanning x-ray diffraction microscopy
    Thibault, Pierre
    Dierolf, Martin
    Menzel, Andreas
    Bunk, Oliver
    David, Christian
    Pfeiffer, Franz
    SCIENCE, 2008, 321 (5887) : 379 - 382
  • [7] HIGH-RESOLUTION ZONE PLATES FOR X-RAY MICROSCOPY
    MORRIS, D
    GENTILI, M
    BACIOCCHI, M
    CONTARINI, S
    DEGASPERIS, P
    GARIAZZO, C
    MAGGIORA, R
    MELPIGNANO, P
    MINNAJA, N
    NATALETTI, P
    ROSEI, R
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 539 - 542
  • [8] PROSPECTS IN HIGH-RESOLUTION X-RAY PHOTOELECTRON MICROSCOPY
    CAZAUX, J
    ULTRAMICROSCOPY, 1985, 17 (01) : 43 - 49
  • [9] High-resolution X-ray computed tomography of impactites
    Koeberl, C
    Denison, C
    Ketcham, RA
    Reimold, WU
    JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2002, 107 (E10)
  • [10] High-resolution x-ray luminescence computed tomography
    Lun, Michael C.
    Li, Changqing
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317