Field Test and Numerical Simulation on the Long-Term Thermal Response of PHC Energy Pile in Layered Foundation

被引:26
|
作者
Zhang, Guozhu [1 ,2 ]
Cao, Ziming [1 ,2 ]
Liu, Yiping [3 ]
Chen, Jiawei [1 ,2 ]
机构
[1] Southeast Univ, Inst Geotech Engn, Nanjing 211189, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Urban Underground Engn & Environm, Nanjing 211189, Peoples R China
[3] Jiangsu Power Design Inst Co Ltd, China Energy Engn Grp, Nanjing 211102, Peoples R China
关键词
PHC energy pile; field test; numerical simulation; long-term thermal response; GROUND HEAT-EXCHANGERS; THERMOMECHANICAL BEHAVIOR; LABORATORY INVESTIGATIONS; PERFORMANCE; TEMPERATURE; EFFICIENCY; PIPE;
D O I
10.3390/s21113873
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Investigation on the long-term thermal response of precast high-strength concrete (PHC) energy pile is relatively rare. This paper combines field experiments and numerical simulations to investigate the long-term thermal properties of a PHC energy pile in a layered foundation. The major findings obtained from the experimental and numerical studies are as follows: First, the thermophysical ground properties gradually produce an influence on the long-term temperature variation. For the soil layers with relatively higher thermal conductivity, the ground temperature near to the energy pile presents a slowly increasing trend, and the ground temperature response at a longer distance from the center of the PHC pile appears to be delayed. Second, the short- and long-term thermal performance of the PHC energy pile can be enhanced by increasing the thermal conductivity of backfill soil. When the thermal conductivities of backfill soil in the PHC pile increase from 1 to 4 W/(m K), the heat exchange amounts of energy pile can be enhanced by approximately 30%, 79%, 105%, and 122% at 1 day and 20%, 47%, 59%, and 66% at 90 days compared with the backfill water used in the site. However, the influence of specific heat capacity of the backfill soil in the PHC pile on the short-term or long-term thermal response can be ignored. Furthermore, the variation of the initial ground temperature is also an important factor to affect the short-and-long-term heat transfer capacity and ground temperature variation. Finally, the thermal conductivity of the ground has a significant effect on the long-term thermal response compared with the short-term condition, and the heat exchange rates rise by about 5% and 9% at 1 day and 21% and 37% at 90 days as the thermal conductivities of the ground increase by 0.5 and 1 W/(m K), respectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Evaluation of thermal response and performance of PHC energy pile: Field experiments and numerical simulation
    Park, Hyunku
    Lee, Seung-Rae
    Yoon, Seok
    Choi, Jung-Chan
    APPLIED ENERGY, 2013, 103 : 12 - 24
  • [2] Numerical Simulation of Bearing Capacity and Consolidation Characteristics of PHC Pile Foundation
    Gong, Shen
    Cai, Guojun
    Liu, Songyu
    Puppala, Anand J.
    PROCEEDINGS OF GEOSHANGHAI 2018 INTERNATIONAL CONFERENCE: GROUND IMPROVEMENT AND GEOSYNTHETICS, 2018, : 178 - 185
  • [3] Numerical Study on the Long-Term Thermal Performance and Ground Temperature Variation of Energy Pile in Multi-layered Soil
    Guo, Yimu
    Zhang, Guozhu
    Liu, Songyu
    Du, Yanjun
    Liu, Zhibin
    ENERGY GEOTECHNICS, SEG-2018, 2019, : 90 - 96
  • [4] Numerical study on long-term monopile foundation response
    Chong, Song-Hun
    Pasten, Cesar
    MARINE GEORESOURCES & GEOTECHNOLOGY, 2018, 36 (02) : 190 - 196
  • [5] Seismic Performance Test Study and Numerical Simulation of PHC Pipe Pile
    China Railway Design Corporation, Tianjin
    300142, China
    J. Railw. Eng. Soc., 1600, 10 (20-24):
  • [6] Model test and numerical simulation of open caisson foundation under long-term lateral loading
    Mu, Baogang
    Ling, Xu
    Zheng, Weifeng
    Mei, Guoxiong
    Ni, Pengpeng
    OCEAN ENGINEERING, 2024, 312
  • [7] Influence of Pile Foundation Construction on Existing Tunnels in a Metro Protection Area: Field Test and Numerical Simulation
    Lin, Gang
    Ke, Wenbin
    Guo, Shuaishuai
    Lin, Zhaorui
    Xu, Changjie
    Chi, Minliang
    Xiao, Yue
    BUILDINGS, 2024, 14 (08)
  • [8] Monitoring and Numerical Study of Long-Term Settlement of Track Bed with Sparse Pile Foundation for Tram
    Xu Z.
    Liu L.
    Wang H.
    Yu J.
    Huang M.
    Tongji Daxue Xuebao/Journal of Tongji University, 2021, 49 (03): : 421 - 430
  • [9] Nonlinear numerical simulation of dynamic response of pile site and pile foundation under earthquake
    Liang, Wenwen
    Leng, Lingye
    Tian, Hao
    Tian, Xiao
    NONLINEAR ENGINEERING - MODELING AND APPLICATION, 2022, 11 (01): : 485 - 493
  • [10] EVALUATION OF LONG-TERM DISPLACEMENTS OF PILE FOUNDATION USING COUPLED FEM AND CENTRIFUGE MODEL TEST
    Danno, Koichiro
    Kimura, Makoto
    SOILS AND FOUNDATIONS, 2009, 49 (06) : 941 - 958