Photothermal Ring Integrated Intraocular Lens for High-Efficient Eye Disease Treatment

被引:57
|
作者
Lin, Yao-Xin [1 ]
Hu, Xue-Feng [2 ]
Zhao, Yang [3 ]
Gao, Yu-Juan [1 ]
Yang, Chao [1 ]
Qiao, Sheng-Lin [1 ]
Wang, Yi [1 ]
Yang, Pei-Pei [1 ]
Yan, Jiao [4 ]
Sui, Xin-Ce [5 ]
Qiao, Zeng-Ying [1 ]
Li, Li-Li [1 ]
Xie, Jiang-Bing [5 ]
Zhu, Si-Quan [3 ]
Wu, Xiao-Chun [4 ]
Li, Yongsheng [2 ]
Wang, Lei [1 ]
Wang, Hao [1 ]
机构
[1] Natl Ctr Nanosci & Technol NCNST, CAS Key Lab Biol Effects Nanomat & Nanosafety, CAS Ctr Excellence Nanosci, 11 Beiyitiao, Beijing 100190, Peoples R China
[2] East China Univ Sci & Technol, Sch Mat Sci & Engn, Key Lab Ultrafine Mat, Lab Low Dimens Mat Chem,Minist Educ, Shanghai 200237, Peoples R China
[3] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
[4] Natl Ctr Nanosci & Technol, CAS Key Lab Standardizat & Measurement Nanotechno, Beijing 100190, Peoples R China
[5] Eyebright Med Technol Co Ltd, Bldg 6,37 Chaoqian Rd, Beijing 102200, Peoples R China
基金
中国国家自然科学基金;
关键词
gold nanorods; nanoparticles; photothermal; posterior capsule opacification; POSTERIOR CAPSULE OPACIFICATION; IN-VIVO; CANCER-TREATMENT; GOLD NANORODS; THERAPY; IMPLANTATION; PREVENTION; CATARACT; VITRO; NANOPARTICLES;
D O I
10.1002/adma.201701617
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Posterior capsule opacification (PCO) is the most common complication after cataract surgery. So far, the only method for PCO treatment is the precisely focused laser surgery. However, it causes severe complications such as physical damages and neuron impairments. Here, a nanostructured photothermal ring integrated intraocular lens (Nano-IOLs) is reported, in which the rim of commercially available IOLs (C-IOLs) is decorated with silica coated Au nanorods (Au@SiO2), for high-efficient prevention of PCO after cataract surgery. The Nano-IOLs is capable of eliminating the residual lens epithelial cells (LECs) around Nano-IOLs under mild laser treatment and block the formation of disordered LECs fibrosis, which eventually leads to the loss of vision. The Nano-IOLs shows good biocompatibility as well as extraordinary region-confined photothermal effect. In vivo studies reveal that PCO occurrence in rabbit models is about 30%-40% by using Nano-IOLs, which is significantly lower than the control group that treated with C-IOLs (100% PCO occurrence) 30 d postsurgery. To the best of our knowledge, it is the first example to integrate nanotechnology with intraocular implants aiming to clinically relevant PCO. Our findings indicate that spatial controllability of photothermal effect from nanomaterials may provide a unique way to intervene the PCO-induced loss of vision.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] The effect of intraocular lens and lens eye on the treatment of macular splits in high myopia
    Mao, Zi-Qing
    Fan, Hui-Min
    Wu, Hong-Xi
    You, Zhi-Peng
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (01) : 181 - 190
  • [2] Nanoporous Gold Ring-Integrated Photothermal Intraocular Lens for Active Prevention of Posterior Capsular Opacification
    Liu, Dong
    Wu, Qianni
    Chen, Wan
    Chen, Kexin
    Lin, Haotian
    Liu, Fanmao
    Xie, Xi
    Chen, Hui-jiuan
    Chen, Weirong
    SMALL, 2022, 18 (34)
  • [3] Cascade catalytic platform modified intraocular lens for high-efficient posterior capsule opacification prevention
    Huang, Huiying
    Zhu, Siqing
    Han, Yuemei
    Liu, Dong
    Liu, Sihao
    Lu, Duoduo
    Wang, Rui
    Lin, Quankui
    CHEMICAL ENGINEERING JOURNAL, 2022, 427
  • [4] High-efficient processing lens with medium-high accuracy
    Jian, Min
    Jiguang Jishu/Laser Technology, 1998, 22 (06): : 1 - 2
  • [5] Design method of high-efficient LED headlamp lens
    Chen, Fei
    Wang, Kai
    Qin, Zong
    Wu, Dan
    Luo, Xiaobing
    Liu, Sheng
    OPTICS EXPRESS, 2010, 18 (20): : 20926 - 20938
  • [6] Design of high-efficient TIR lens for tailored illumination with high contrast
    Sun, Xiang
    Zhu, Zhen-Min
    Yuan, Jie
    Peng, Bo
    OPTICS AND LASER TECHNOLOGY, 2019, 111 : 240 - 248
  • [7] Design of high-efficient freeform LED lens for road illumination
    Moiseev, Mikhail A.
    Doskolovich, Leonid L.
    Kazanskiy, Nikolay L.
    ILLUMINATION OPTICS II, 2011, 8170
  • [8] High-efficient integrated electronic ballast for compact fluorescent lamps
    Ponce, M
    Martínez, AJ
    Correa, J
    Cotorogea, M
    Arau, J
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (02) : 532 - 542
  • [9] High-efficient and high-accurate integrated division-of-time polarimeter
    Liu, Wei
    Liao, Jiawen
    Yu, Yu
    Zhang, Xinliang
    APL PHOTONICS, 2021, 6 (07)
  • [10] Visual outcome with the Array multifocal intraocular lens in patients with concurrent eye disease
    Kamath, GG
    Prasad, S
    Danson, A
    Phillips, RP
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04): : 576 - 581