Key Technologies For Ultra-Wideband Pds Detection In Transformer Under Ac/Dc Withstand Voltage Tests, Part 4: Feasibility Analysis Of Separation Or Grouping Technology Based On Pulse Current Sequence

被引:0
|
作者
Fu, Chen-zhao [1 ]
Si, Wen-rong [1 ]
Wang, Xiao-ming [2 ]
Wu, Xu-tao [3 ]
Zhou, Xiu [3 ]
Yan, Nian-ping [4 ]
Zeng, Lei-lei [4 ]
Lu, Qi-yu [5 ]
Song, Ping [5 ]
Cao, Pei [1 ]
He, Lin [1 ]
Yuan, Peng [6 ]
机构
[1] State Grid Shanghai Elect Power Res Inst, Shanghai 200437, Peoples R China
[2] State Grid Jiangxi Elect Power Co Ltd, Nanchang 330077, Jiangxi, Peoples R China
[3] State Grid Ningxia Elect Power Res Inst, Yinchuan 750011, Ningxia, Peoples R China
[4] State Grid Jiangxi Elect Power Res Inst, Nanchang 330096, Jiangxi, Peoples R China
[5] State Grid Shanghai Municipal Elect Power Co, Shanghai 200122, Peoples R China
[6] Xian MaoRong Power Equipment Co Ltd, Xian 710048, Peoples R China
关键词
PD; separation and clustering; pulse current sequence; transformer; withstand test; ON-FIELD MEASUREMENTS; PARTIAL DISCHARGE; INFERENCE; IDENTIFICATION;
D O I
10.1109/ICSGEA51094.2020.00026
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Currently, the AC and DC withstand voltage PD test based on the traditional pulse current method with wide-band or narrowband according the IEC 60270, the detection frequency band is only within 1 MHz, which greatly loses the information in time and frequency domain of the pulse current waveforms. So it is always difficult to eliminate the random interference pulse signals at the background of the substation, which seriously affects the test process. While the 4.6 "ultra-wideband instruments for PD detection" is defined based on PD pulse current waveform in the IEC 60270, but due to lack of the experimental research and engineering applications, no recommendations have been made for this type of method. In this paper, we summarized the characteristics of PD pulse current waveform in time and frequency domain, and intelligent analysis includes separation and clustering technologies, to make the feasibility analysis of anti-interference technology based on the PD pulse current sequence obtained using the ultra-wideband detection.
引用
收藏
页码:84 / 89
页数:6
相关论文
共 3 条
  • [1] Key Technologies For Ultra-Wideband Pds Detection In Transformer Under Ac/Dc Withstand Voltage Tests, Part 1: Application Status Of Conventional Pulse Current Method
    Cao, Pei
    Huang, Hua
    Ji, Yi-ping
    Tian, Hao-yang
    Lu, Zhi-hao
    Wu, Xin-ye
    Zhang, Qi-qi
    Yan, Nian-ping
    Wu, Xu-tao
    Li, Xiu-guang
    Yuan, Peng
    Si, Wen-rong
    2020 5TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2020), 2020, : 10 - 15
  • [2] Key Technologies For Ultra-Wideband Pds Detection In Transformer Under Ac/Dc Withstand Voltage Tests, Part 3: Comments On The Anti-Interference Technology
    Zhou, Xiu
    Zhang, Qing-ping
    Wu, Xu-tao
    Si, Wen-rong
    Yan, Nian-ping
    Li, Xiu-guang
    He, Ning-hui
    Ma, Yun-long
    Tian-Tian
    Niu, Bo
    Luo, Yan
    Liu, Wei-feng
    2020 5TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2020), 2020, : 79 - 83
  • [3] Key technologies for ultra-wideband PDs detection in transformer under AC/DC withstand voltage tests, part 2: Overview of on-site PD test of converter transformer
    Zeng, Lei-lei
    Yan, Nian-ping
    Wang, Xiao-ming
    Si, Wen-rong
    Fu, Chen-zhao
    Zhou, Xiu
    Wang, Peng
    Li, Tang-bing
    Liu, Yu-ting
    Wan, Hua
    Xu, Bi-chuan
    Yuan, Peng
    2020 5TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2020), 2020, : 16 - 20