Water vapor and ozone profiles with a CO2 dial system in South Italy

被引:3
|
作者
Bellecci, C
Caputi, G
DeDonato, F
Gaudio, P
Valentini, M
机构
关键词
lidar; dial water vapour; ozone; tropospheric pollution;
D O I
10.1117/12.258140
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
In this paper we present the work carried out at the University of Calabria regarding a prototype of a dial system. This has been realised for remote pollution monitoring. Most of the effort have been done to perform several measurements on an horizontal path in order to scan the wide surrounding area. The concentrations of ozone and water vapour have been carried out using two different methods both related with the dial technique. With the integrated one average concentrations have been evaluated up to 5 km using topographical targets. In the range resolution technique profile of ozone and water vapour have been performed up to 700 m with a spatial resolution of about 30 m. Although the system needs a revision in several subsystem of its set up, the experimentation has pointed out the performances available and the necessary improvements.
引用
收藏
页码:54 / 61
页数:2
相关论文
共 50 条
  • [1] CO2 DIAL MEASUREMENTS OF WATER-VAPOR
    GRANT, WB
    MARGOLIS, JS
    BROTHERS, AM
    TRATT, DM
    APPLIED OPTICS, 1987, 26 (15): : 3033 - 3042
  • [2] Comprehensive system model for CO2 DIAL
    Schmitt, M
    McVey, B
    Cooke, B
    Busch, G
    GAS AND CHEMICAL LASERS, 1996, 2702 : 95 - 103
  • [3] MEASUREMENTS OF THE URBAN OZONE VERTICAL PROFILE WITH AN AIRBORNE CO2 DIAL
    ITABE, T
    ASAI, K
    ISHIZU, M
    ARUGA, T
    IGARASHI, T
    APPLIED OPTICS, 1989, 28 (05): : 931 - 934
  • [4] Raman DIAL measurement of ozone and water vapor in the lower troposphere
    Lazzarotto, B
    Larchevêque, G
    Quaglia, P
    Simeonov, V
    Van den Bergh, H
    Calpini, B
    ENVIRONMENTAL SENSING AND APPLICATIONS, 1999, 3821 : 54 - 61
  • [5] Water vapor, CO2, and temperature profiles in and above a forest - accuracy assessment of an unattended measurement system
    Molder, Meelis
    Lindroth, Anders
    Halldin, Sven
    2000, American Meteorological Soc, Boston, MA, USA (17)
  • [6] Water vapor, CO2, and temperature profiles in and above a forest -: Accuracy assessment of an unattended measurement system
    Mölder, M
    Lindroth, A
    Halldin, S
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2000, 17 (04) : 417 - 425
  • [7] Evolution study of a water vapour plume using a mobile CO2 DIAL system
    Bellecci, C
    Casella, L
    Federico, S
    Gaudio, P
    Lo Feudo, T
    Martellucci, S
    Richetta, M
    REMOTE SENSING OF CLOUDS AND THE ATMOSPHERE VI, 2002, 4539 : 180 - 190
  • [8] CO2 DIAL system:: Construction, measurements and future development
    Viceník, J
    11TH SLOVAK-CZECH-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 1999, 3820 : 314 - 321
  • [9] REMOTE PROBING OF THE ATMOSPHERE USING A CO2 DIAL SYSTEM
    KILLINGER, DK
    MENYUK, N
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1981, 17 (09) : 1917 - 1929
  • [10] Improvement of Calabria university CO2 laser dial system
    Aversa, P
    Bellecci, C
    Michelangeli, GB
    Caputi, G
    DeDonato, F
    Gaudio, P
    Valentini, M
    Zoccali, R
    LIDAR ATMOSPHERIC MONITORING, 1997, 3104 : 154 - 157