Air Kerma Rate estimation by means of in-situ gamma spectrometry: A Bayesian approach

被引:3
|
作者
Cabal, Gonzalo [1 ,2 ]
Kluson, Jaroslav [1 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Dosimetry & Applicat Ionizing Radiat, CR-11519 Prague 1, Czech Republic
[2] Acad Sci Czech Republic, Inst Nucl Phys, Dept Radiat Dosimetry, Prague 18086 8, Czech Republic
关键词
Air Kerma; Gamma spectrometry; Environmental radiation measurement; Bayesian analysis; Spectra unfolding;
D O I
10.1016/j.apradiso.2009.09.062
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an Nal(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:804 / 806
页数:3
相关论文
共 50 条
  • [1] In situ gamma-ray spectrometry in forests:: Determination of kerma rate in air from 137Cs
    Gering, F
    Kiefer, P
    Fesenko, S
    Voigt, G
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2002, 61 (01) : 75 - 89
  • [2] In-situ Field Gamma Spectrometry in a Radionuclide Air Sampler
    Lebel, Luke
    Barlow, Kyle
    Boulianne, Diana
    Clouthier, Tony
    HEALTH PHYSICS, 2022, 123 (04): : 295 - 304
  • [3] In-situ field gamma spectrometry in a radionuclide air sampler Response
    Evans, William C. C.
    HEALTH PHYSICS, 2023, 124 (03): : 221 - 222
  • [4] In-situ gamma spectrometry in environmental monitoring
    Kluson, J.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 529 - 535
  • [5] Follow up of the Chernobyl Cs-137 concentration in Belgium by means of in-situ gamma spectrometry
    Uyttenhove, J
    VanWaeyenberge, B
    Pomme, S
    Hardeman, F
    Buysse, J
    Culot, JP
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C180 - C182
  • [6] National primary standard for the unit of air kerma, air kerma rate, exposure, exposure rate, and x- and gamma-ray energy flux
    Oborin, A. V.
    Villevalde, A. Yu.
    Trofimchuk, S. G.
    MEASUREMENT TECHNIQUES, 2012, 55 (08) : 849 - 857
  • [7] National primary standard for the unit of air kerma, air kerma rate, exposure, exposure rate, and x- and gamma-ray energy flux
    A. V. Oborin
    A. Yu. Villevalde
    S. G. Trofimchuk
    Measurement Techniques, 2012, 55 : 849 - 857
  • [8] GONIO - AN ORIENTATION DETECTOR AND ENVIRONMENTAL GAMMA-AIR KERMA RATE METER
    CHEMTOB, M
    CHUITON, R
    CHAPUIS, JC
    PRIGENT, R
    WALES, L
    RADIATION PROTECTION DOSIMETRY, 1993, 46 (01) : 55 - 61
  • [9] Air kerma rate constants for gamma emitters used most often in practice
    Ninkovic, MM
    Raicevic, JJ
    Adrovic, F
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 247 - 250
  • [10] GAMMA SPECTROMETRY AND GAMMA SCANNING APPARATUS IN-SITU EXAMINATION OF IRRADIATION FACILITIES
    PERVES, JP
    MICHEL, F
    CHEVALLI.M
    BULLETIN D INFORMATIONS SCIENTIFIQUES ET TECHNIQUES DU COMMISSARIAT A L ENERGIE ATOMIQUE, 1973, (177): : 45 - 50