IONISATION CHAMBER FOR MEASUREMENT OF PULSED PHOTON RADIATION FIELDS

被引:4
|
作者
Ginzburg, D. [1 ]
机构
[1] Rotem Ind Ltd, Radiat Detect Dept, Rotem Ind Pk, IL-86800 Beer Sheva, Israel
关键词
ACTIVE PERSONAL DOSIMETERS; INTERVENTIONAL RADIOLOGY;
D O I
10.1093/rpd/ncw145
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of pulsed photon radiation in medical, industrial and security sectors has vastly increased during the recent years. The length of pulse from different X-ray flash generators that are commonly used as either portable, battery-operated or fixed systems can be as low as a few femtoseconds. However, the majority of radiation protection instruments, especially various active electronic dosemeters, have limitations when operated in pulsed fields. This study presents measurements that were performed using the dose-integration mode of the RI-02 and Ram Ion survey metres, which are based on ventilated ionisation chamber, when exposed to different pulsed X-ray sources. An intercomparison between the results that were obtained with the survey metres and those that were obtained with thermoluminescence dosemeter, reference passive dosemeter, show good agreement (deviation lies within 10%).
引用
收藏
页码:297 / 301
页数:5
相关论文
共 50 条
  • [1] Novel reference radiation fields for pulsed photon radiation installed at PTB
    Klammer, J.
    Roth, J.
    Hupe, O.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (03) : 478 - 482
  • [2] Photon dosimetry using plastic scintillators in pulsed radiation fields
    Chichester, David L.
    Blackburn, Brandon W.
    Johnson, James T.
    Watson, Scott M.
    OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY III, 2007, 6540
  • [3] Evaluation of the fluid filled ionisation chamber TM31018 (PTW microLion) for the measurement of relative dose profile of high energetic photon radiation
    Scherf, C.
    Licher, J.
    Moog, J.
    Kara, E.
    Roedel, C.
    Ramm, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 49 - 49
  • [4] Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose
    Gotz, M.
    Karsch, L.
    Pawelke, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3316 - 3316
  • [5] Variation of radiation doses estimated on time resolved photon energy spectra of pulsed radiation fields
    Urabe, I
    Nagayasu, M
    Tsujimoto, T
    Kobayashi, K
    Yoshimoto, TA
    Nakashima, Y
    Oda, K
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D579 - D581
  • [6] WALL THICKNESS OPTIMISATION OF AN IONISATION CHAMBER FOR DIRECTIONAL DOSE EQUIVALENT RATE MEASUREMENT AT LOW AND MEDIUM PHOTON ENERGIES
    Singh, Sunil K.
    Kulkarni, M. S.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 469 - 474
  • [7] PROPERTIES OF AN ELECTRET IONIZATION-CHAMBER FOR INDIVIDUAL DOSIMETRY IN PHOTON RADIATION-FIELDS
    DORSCHEL, B
    PRETZSCH, G
    RADIATION PROTECTION DOSIMETRY, 1985, 12 (04) : 339 - 343
  • [8] Spectrometry of pulsed photon radiation
    Behrens, Rolf
    Zutz, Hayo
    Busse, Julian
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (01)
  • [9] Ionisation chamber
    Imarisio, G
    ELECTRONICS WORLD, 1999, 105 (1755): : 246 - 246
  • [10] Photon kerma determination using a high pressure graphite ionisation chamber in mixed fields of neutrons of energy 44 and 66 MeV
    Golnik, N
    Brede, HJ
    Schrewe, UJ
    Zielczynski, M
    RADIATION PROTECTION DOSIMETRY, 2000, 88 (02) : 135 - 142