MONTE CARLO SIMULATION OF LINAC IRRADIATION WITH DYNAMIC WEDGES

被引:0
|
作者
Chang, Kwo-Ping [1 ,2 ]
Chen, Lu-Yu [3 ]
Chien, Yu-Huang [4 ]
机构
[1] Tzu Chi Coll Technol, Dept Med Imaging & Radiol Sci, Hualien 970, Taiwan
[2] Tzu Chi Coll Technol, Inst Radiol Sci, Hualien 970, Taiwan
[3] Lotung Poh Ai Hosp, Dept Radiol, Luodong Township 265, Yilan County, Taiwan
[4] Mennonite Christian Hosp, Dept Radiat Therapy, Hualien 970, Taiwan
关键词
CLINICAL IMPLEMENTATION; COLLIMATOR MOTION; VALIDATION;
D O I
10.1093/rpd/ncu211
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims to simulate the dose distributions of LINAC with dynamic wedges (DWs) under various field sizes and wedge angles by the BEAMnrc code with DYNJAWS component module. These were compared with those calculated by the treatment planning system (TPS) and the measured data. All percentage depth doses (PDDs) were found to be in good agreement between TPS, Monte Carlo (MC) and measurements made in open fields and fields with DWs. For dose profiles, compared with the MC and the measurements, TPS gives reliable results for large field sizes (>10 x 10 cm(2)) but results in significant errors in small field sizes (5 x 5 cm(2)). The entrance surface doses calculated by TPS were found to be significantly overestimated. For depths deeper than 0.5 cm, TPS yields PDDs in agreement with MC simulations.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [1] Monte Carlo simulation of linac using PRIMO
    Li, Yang
    Sun, Xingru
    Liang, Ying
    Hu, Yuchao
    Liu, Chenbin
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [2] Monte Carlo simulation of linac using PRIMO
    Yang Li
    Xingru Sun
    Ying Liang
    Yuchao Hu
    Chenbin Liu
    Radiation Oncology, 17
  • [3] Monte Carlo simulation of the Elekta VersaHD linac
    Borzov, E.
    Nevelsky, A.
    Daniel, S.
    Bar-Deroma, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S717 - S717
  • [4] A geometrical model for the Monte Carlo simulation of the TrueBeam linac
    Rodriguez, M.
    Sempau, J.
    Fogliata, A.
    Cozzi, L.
    Sauerwein, W.
    Brualla, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : N219 - N229
  • [5] Monte Carlo Simulation of Varian Linac Using PRIMO
    Li, Y.
    Sun, X.
    Liu, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Monte Carlo simulation of the Varian Clinac 600C accelerator dynamic and physical wedges
    Soares, S.
    Chaves, A.
    Peralta, L.
    Lopes, M. C.
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [7] Monte Carlo simulation of radiation field optimization for medical linac
    Zhao, Hongbin
    Zhang, Xin
    Bao, Shanglian
    Huang, Feizeng
    Li, Quanfeng
    Transactions of Nanjing University of Aeronautics and Astronautics, 2010, 27 (01) : 7 - 12
  • [8] Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation
    T. Kairn
    S. B. Crowe
    C. M. Poole
    A. L. Fielding
    Australasian Physics & Engineering Sciences in Medicine, 2009, 32 : 129 - 135
  • [9] Determination of the initial beam parameters in Monte Carlo linac simulation
    Aljarrah, K
    Sharp, GC
    Neicu, T
    Jiang, SB
    MEDICAL PHYSICS, 2006, 33 (04) : 850 - 858
  • [10] Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation
    Kairn, T.
    Crowe, S. B.
    Poole, C. M.
    Fielding, A. L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (03) : 129 - 135