A Silicon Drift Detector-CMOS front-end system for high resolution X-ray spectroscopy up to room temperature

被引:32
|
作者
Bertuccio, G. [1 ,2 ]
Ahangarianabhari, M. [1 ,2 ]
Graziani, C. [1 ]
Macera, D. [1 ,2 ]
Shi, Y. [1 ,2 ]
Rachevski, A. [3 ]
Rashevskaya, I. [3 ]
Vacchi, A. [3 ]
Zampa, G. [3 ]
Zampa, N. [3 ]
Bellutti, P. [4 ]
Giacomini, G. [4 ]
Picciotto, A. [4 ]
Piemonte, C. [4 ]
机构
[1] Politecn Milan, Dept Elect Engn, I-22100 Como, Italy
[2] Ist Nazl Fis Nucl, Natl Inst Nucl Phys, I-20133 Milan, Italy
[3] Ist Nazl Fis Nucl, Natl Inst Nucl Phys, I-34149 Trieste, Italy
[4] Fdn Bruno Kessler, I-38123 Trento, Italy
来源
JOURNAL OF INSTRUMENTATION | 2015年 / 10卷
关键词
Solid state detectors; X-ray detectors; Analogue electronic circuits; Front-end electronics for detector readout;
D O I
10.1088/1748-0221/10/01/P01002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A system constituted by a Silicon Drift Detector (SDD), fabricated with an innovative technology for minimizing the anode current, and a new CMOS charge sensitive preamplifier (CSA), designed for ultimate low noise performance, has been realized and experimentally characterized. The SDD is hexagonal with an active area of 13mm(2). The current density measured at the anode with the detector in operating condition is 25 pA/cm(2) at + 20 degrees C. The CSA - named SIRIO - has intrinsic Equivalent Noise Charge (ENC) ranging from 2.9 to 1.5 electrons r.m.s. at 0.8 mu s and 11 mu s peaking times at room temperature, respectively. With the SDD-SIRIO system at + 21 degrees C, an energy resolution of 141 eV FWHM on the Fe-55 line at 5.9 keV and 74 eV FWHM on the pulser line with a noise threshold of 170 eV have been measured at 0.8 mu s peaking time. The system has been tested from -30 degrees C to + 30 degrees C with energy resolution from 124 eV to 148 eV FWHM at 5.9 keV. A moderate cooling at + 10 degrees C is sufficient to reach 133 eV FWHM at 5.9 keV.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] X-Ray Silicon Drift Detector-CMOS Front-End System with High Energy Resolution at Room Temperature
    Bertuccio, G.
    Ahangarianabhari, M.
    Graziani, C.
    Macera, D.
    Shi, Y.
    Gandola, M.
    Rachevski, A.
    Rashevskaya, I.
    Vacchi, A.
    Zampa, G.
    Zampa, N.
    Bellutti, P.
    Giacomini, G.
    Picciotto, A.
    Piemonte, C.
    Zorzi, N.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 400 - 406
  • [2] Silicon drift detectors for high resolution room temperature X-ray spectroscopy
    Lechner, P
    Eckbauer, S
    Hartmann, R
    Krisch, S
    Hauff, D
    Richter, R
    Soltau, H
    Struder, L
    Fiorini, C
    Gatti, E
    Longoni, A
    Sampietro, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 346 - 351
  • [3] ROOM-TEMPERATURE, HIGH-RESOLUTION X-RAY SPECTROSCOPY WITH SILICON DRIFT CHAMBERS
    PINOTTI, E
    LONGONI, A
    GAMBELLI, M
    STRUDER, L
    LECHNER, P
    VANZANTHIER, C
    KRANER, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (01) : 12 - 16
  • [4] A CdTe pixel detector-CMOS preamplifier for room temperature high sensitivity and energy resolution X and γ ray spectroscopic imaging
    Sammartini, M.
    Gandola, M.
    Mele, F.
    Garavelli, B.
    Macera, D.
    Pozzi, P.
    Bertuccio, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 910 : 168 - 173
  • [5] A CMOS detector readout front-end for X-ray digital radiography systems
    Adachi, S
    Tokuda, S
    Ishida, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 249 - 255
  • [6] Front-end ASIC for high resolution x-ray spectrometers
    De Geronimo, Gianluigi
    Chen, Wei
    Fried, Jack
    Li, Zheng
    Pinelli, Donald A.
    Rehak, Pavel
    Vernon, Emerson
    Gaskin, Jessica A.
    Ramsey, Brian D.
    Anelli, Giovanni
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 26 - 31
  • [7] Front-end ASIC for high resolution X-ray spectrometers
    De Geronimo, Gianluigi
    Chen, Wei
    Fried, Jack
    Li, Zheng
    Pinelli, Donald A.
    Rehak, Pavel
    Vernon, Emerson
    Gaskin, Jessica A.
    Ramsey, Brian D.
    Anelli, Giovanni
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1604 - 1609
  • [8] Silicon drift detectors for high count rate X-ray spectroscopy at room temperature
    Lechner, P
    Fiorini, C
    Hartmann, R
    Kemmer, J
    Krause, N
    Leutenegger, P
    Longoni, A
    Soltau, H
    Stötter, D
    Stötter, R
    Strüder, L
    Weber, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 281 - 287
  • [9] Pixel Drift Detector (PixDD) - SIRIO: an X-ray spectroscopic system with high energy resolution at room temperature
    Sammartini, M.
    Gandola, M.
    Mele, F.
    Bertuccio, G.
    Ambrosino, F.
    Bellutti, P.
    Borghi, G.
    Campana, R.
    Caselle, M.
    Cirrincione, D.
    Evangelista, Y.
    Feroci, M.
    Ficorella, F.
    Fiorini, M.
    Fuschino, F.
    Grassi, M.
    Labanti, C.
    Malcovati, P.
    Picciotto, A.
    Rachevski, A.
    Rashevskaya, I
    Zampa, G.
    Zampa, N.
    Zorzi, N.
    Vacchi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 953
  • [10] A HIGH-RESOLUTION SILICON DRIFT CHAMBER FOR X-RAY SPECTROSCOPY
    GAUTHIER, C
    GOULON, J
    MOGUILINE, E
    ELLEAUME, P
    FEITE, S
    GABURRO, Z
    LONGONI, A
    GATTI, E
    DRESSLER, P
    LAMPERT, MO
    HENCK, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (01): : 258 - 262