Calibration of Defibrillator Analyzer by Voltage Square Method

被引:0
|
作者
Torres, Fabricio Goncalves [1 ]
Apolinario, Felipe Santiago [1 ]
Dias, Regis Renato [1 ]
Santos, Tiago Lopes [1 ]
机构
[1] Inst Pesquisas Tecnol Estado Sao Paulo IPT, Sao Paulo, SP, Brazil
关键词
Analyzer defibrillator; Calibration; Metrology;
D O I
10.1007/978-981-13-2119-1_126
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Defibrillator is an electromedical equipment used to rescue patients with cardiac arrhythmias. The success rate in the use of the equipment is high, however, it is necessary that the defibrillator is in good condition and, therefore, must be tested by means of a defibrillator analyzer. There is a need for the defibrillator analyzers to be calibrated and their measurements have metrological traceability. The measurements carried out by the analyzers must not exceed the tolerances determined by the medical standards and therefore the equipment used in the calibration of these devices must have an uncertainty lower than the required tolerances. The present work has the purpose of presenting a calibration method of defibrillator analyzer by means of the integration of voltage square level, which has an uncertainty lower than the tolerance required by the standards of electromedical. The uncertainty components that are relevant for calibration are described. The proposed method was tested in the calibration of a defibrillator analyzer and the results obtained from the calibration are presented.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 50 条
  • [1] Calibration Standard for Impulse Energy of Defibrillator and Defibrillator Analyzer
    Zhao, Wei
    Shao, Haiming
    Zhang, Huanghui
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [2] Energy calibration technique of defibrillator analyzer
    Zhao Wei
    Shao Haiming
    Lin Feipeng
    Liang Bo
    Ding Jiandong
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 1, 2015, : 313 - 317
  • [3] Establishment of calibration equipment for defibrillator analyzer and evaluation of measurement uncertainty
    Wang, Yunling
    Zhan, Zhiqiang
    Yu, Lei
    2020 2ND INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE COMMUNICATION AND NETWORK SECURITY (CSCNS2020), 2021, 336
  • [4] CSIR-NPL establishes an apex-level calibration facility for defibrillator analyzer and defibrillator machine
    Rajesh
    Tanwar, V. K.
    Sumana, G.
    Agarwal, V. V.
    Ojha, V. N.
    Aswal, D. K.
    CURRENT SCIENCE, 2019, 117 (02): : 179 - 180
  • [5] A MULTILINE METHOD OF NETWORK ANALYZER CALIBRATION
    MARKS, RB
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (07) : 1205 - 1215
  • [6] Research on Calibration Method of Wideband Power Analyzer
    Hu Zhiyuan
    Jin Haibin
    Youli
    Pengcheng
    2014 XXXITH URSI GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM (URSI GASS), 2014,
  • [7] CALIBRATION METHOD FOR ROTATING-ANALYZER ELLIPSOMETERS
    DENIJS, JMM
    HOLTSLAG, AHM
    HOEKSTA, A
    VANSILFHOUT, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (09): : 1466 - 1471
  • [8] CALIBRATION OF DIFFERENTIAL MOBILITY ANALYZER BY VISUAL METHOD
    KOUSAKA, Y
    OKUYAMA, K
    ENDO, Y
    JOURNAL OF AEROSOL SCIENCE, 1981, 12 (04) : 339 - &
  • [9] A SIMPLE AND ACCURATE METHOD FOR INFRARED GAS ANALYZER CALIBRATION
    JOHNSON, CE
    CALDAS, LS
    JOURNAL OF EXPERIMENTAL BOTANY, 1984, 35 (156) : 1083 - 1086
  • [10] A Novel AVM Calibration Method Using Unaligned Square Calibration Boards
    Lee, Jung Hyun
    Lee, Dong-Wook
    SENSORS, 2021, 21 (07)