Numerical and experimental investigation of a thermosiphon solar water heater system thermal performance used in domestic applications

被引:6
|
作者
Jasim, Ayoob Khalid [1 ]
Freegah, Basim [2 ]
Alhamdo, Mohammed Hamed [2 ]
机构
[1] Mustansiriyah Univ, Dept Mech Engn, Baghdad, Iraq
[2] Mustansiriyah Univ, Engn Coll, Dept Mech Engn, Sec 551,St 46,Home 127, Baghdad, Iraq
关键词
amount of working fluid; computational fluid dynamics (CFD); natural convection phenomena; thermal performance; thermosiphon;
D O I
10.1002/htj.22089
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermosiphon is a passive heat exchange method, which circulates a fluid within a system without the need for any electrical or mechanical pumps. The thermosiphon is based on natural convection where the thermal expansion occurs when the temperature difference has a corresponding difference in density across the loop. Thermosiphons are used in different applications such as solar energy collection, automotive systems, and electronics. The current study aims to investigate thermosiphon thermal performance used in domestic applications. The thermal performance of a thermosiphon has been studied by many researchers; however, according to the knowledge of the authors, the influence of the amount of the working fluid on the thermal output has not yet been investigated. Therefore, the influence of the amount of working fluid within the riser pipe has been investigated on the thermal performance of the thermosiphon. In the current study, a computational fluid dynamics model is involved. This model has been validated by comparison with experimental findings. The maximum variation between numerical and experimental results is 14.2% and 11.2% for the working fluid at the inlet and outlet of the absorber pipe, respectively. Furthermore, the results show that the amount of working fluid inside the closed thermosiphon has a great influence on the thermal performance of the system. Additionally, it is found that Case-B, when the amount of working fluid is less than by 10% compared to the traditional model, is the best case among all cases under study. Furthermore, a correlation equation to predict water temperature at the exit of the absorber pipe has been established with an accuracy of 95.05%.
引用
收藏
页码:4575 / 4594
页数:20
相关论文
共 50 条
  • [1] Experimental and numerical analysis of a thermosyphon solar water heater for domestic applications
    Freegah, Basim
    Al-Tabbakh, Aouf A.
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2019, 81 (01): : 117 - 132
  • [2] Experimental and numerical investigation of a solar thermocline system for domestic water heating applications
    Cheema, T. A.
    Javaid, H.
    Yildizhan, H.
    Tariq, M. H.
    Basharat, M. T.
    Subhani, Z. M.
    Fakhraei, O.
    Gorjian, S.
    Ahmadi, M. H.
    Pandey, C.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (16) : 8787 - 8798
  • [3] Artificial neural networks used for the performance prediction of a thermosiphon solar water heater
    Kalogirou, SA
    Panteliou, S
    Dentsoras, A
    RENEWABLE ENERGY, 1999, 18 (01) : 87 - 99
  • [4] Thermal performance of a solar water heater with internal exchanger using thermosiphon system in Cote d'Ivoire
    Koffi, Paul Magloire E.
    Koua, Blaise K.
    Gbaha, Prosper
    Toure, Siaka
    ENERGY, 2014, 64 : 187 - 199
  • [5] Experimental and numerical investigation of thermal performance in solar air heater with conical surface
    Abuska, Mesut
    Kayapunar, Arif
    HEAT AND MASS TRANSFER, 2021, 57 (11) : 1791 - 1806
  • [6] Experimental and numerical investigation of thermal performance in solar air heater with conical surface
    Mesut Abuşka
    Arif Kayapunar
    Heat and Mass Transfer, 2021, 57 : 1791 - 1806
  • [7] Numerical and experimental investigation of thermosyphon solar water heater
    Zelzouli, Khaled
    Guizani, Amenallah
    Kerkeni, Chakib
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 913 - 922
  • [8] Experimental and numerical investigation of a thermosyphon solar water heater
    Kohole, Yemeli Wenceslas
    Tchuen, Ghislain
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 41 (04) : 384 - 394
  • [9] Experimental investigation on enhancement of thermal performance with obstacle placing in the horizontal hot water tank used in solar domestic hot water system
    Erdemir, Dogan
    Atesoglu, Hakan
    Altuntop, Necdet
    RENEWABLE ENERGY, 2019, 138 : 187 - 197
  • [10] Theoretical and experimental study of solar water heater with internal exchanger using thermosiphon system
    Koffi, P. M. E.
    Andoh, H. Y.
    Gbaha, P.
    Tour, S.
    Ado, G.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (08) : 2279 - 2290